SAGD is a thermal recovery process in which steam oil ratio, SOR, is a key parameter that can affect the economic outcome of the process. Reservoirs with underlying or overlying lean bitumen present challenges for SAGD as they can act as a heat sink. Water has higher heat capacity than the bitumen and thus requires more steam to heat up the reservoir leading to higher SOR. The potential outcome of operating SAGD in these conditions may be lower bitumen rate and higher steam injection rate, both of which affect plant throughput and thus the economic matrix of SAGD. This paper looks at the performance of SAGD process in the presence of top lean bitumen. It will examine the theoretical CSOR that is needed to produce the bitumen with different water saturations and will highlight the key parameters of lean bitumen affecting SAGD performance. The paper reviews performance of several fields where lean bitumen is present. The paper also analyzes simulation results to examine the impact of water saturation and the size of lean bitumen resource on the SAGD process.
Physical model tests were simulated non-aqueous phase liquid (NAPL) spill in two-dimensional
domain above the water table. Four laboratory experiments were carried out in the sand-filled
tank. The evolution of the plume was observed through the transparent side of this tank and the
contaminant front was traced at appropriate intervals. The materials used in these experiments
were Al-Najaf sand as a porous medium and kerosene as contaminant.
The results of the experiments showed that after kerosene spreading comes to a halt (ceased) in
the homogeneous sand, the bulk of this contaminant is contained within a pancake-shaped lens
situated on top of the capillary fringe.
The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.
Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In
... Show Moremethodology six sigma Help to reduce defects by solving problems effectively, and works Lean to reduce losses through the flow of the manufacturing process and when integrating these two methodologies (Lean and six sigma), the methodology of Lean six sigma will form the entrance to the organizers of the optimization process and increase the quality and reduce lead times and costs . by focusing on the needs of the customer. this process uses statistical tools and techniques to analyze and improve processes.
We have conducted this research in the General Company for Electrical Industries and adopted its product (machine cooling water three taps) as a sample for research. In order to determine t
... Show MoreThe developments accelerated in technology and rapid changes in the environment and increase numbers industrial countries and different desires and requirements of customers, lead to be produced in large quantities is not feasible due to changes listed above as well as the need to product variety and change in tastes and desires of consumers, all above led not to enable companies to discharge their products in the case of mass production and created the need to devise ways and new methods fit with the current situation, and accounting point no longer the traditional accounting systems able to meet the requirements needed by the companies to make decisions and know where waste and loss of resources resulting to invent new style away from
... Show MoreThe map of permeability distribution in the reservoirs is considered one of the most essential steps of the geologic model building due to its governing the fluid flow through the reservoir which makes it the most influential parameter on the history matching than other parameters. For that, it is the most petrophysical properties that are tuned during the history matching. Unfortunately, the prediction of the relationship between static petrophysics (porosity) and dynamic petrophysics (permeability) from conventional wells logs has a sophisticated problem to solve by conventional statistical methods for heterogeneous formations. For that, this paper examines the ability and performance of the artificial intelligence method in perme
... Show MoreRivers Tigris and Euphrates, as well as the wetlands in southern Iraq and the Diyala River, were all included in the evaluation of earlier studies on the variety and factors impacting fish in Iraqi waters. Different studies documented different types, and the number of species recorded varied between the studies, which could be explained by the registration of some species, synonyms, differs from the registration of some species with synonymous names By mistake, as well as recording new species in times that followed some previous studies, Also, the difference in some factors, including the pollution of some waterways, leads to a difference in the existing species, so we find the presence of species that are tolerant of pollution. There are
... Show MoreKA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1
This study was concerned with using ozone gas in drinking water treatment plant at Ibn-Sina Company. The main purpose of this research is to find the best contactor for ozone unit proposed. An investigation was conducted to study the absorption of ozone by water in two type of absorber. The effects of the process variables (such as height of water column, contact time, and pH) on the amount of ozone absorbed were investigated. Box-Wilson central composite rotatable design is used to design the experimental work for the mentioned variables. It was found that the optimum value of the variables studied was:
i) Height of water column (90 cm)
ii) Contact time (17-18 min)
iii) PH (7 - 7.5)