Preferred Language
Articles
/
3RYqFIcBVTCNdQwCKzTN
DFT + U and ab initio atomistic thermodynamics approache for mixed transitional metallic oxides: A case study of CoCu 2 O 3 surface terminations
...Show More Authors

This study develops a systematic density functional theory alongside on-site Coulomb interaction correction (DFT + U) and ab initio atomistic thermodynamics approachs for ternary (or mixed transitional metal oxides), expressed in three reservoirs. As a case study, among notable multiple metal oxides, synthesized CoCu2O3 exhibits favourable properties towards applications in solar, thermal and catalytic processes. This progressive contribution applies DFT + U and atomistic thermodynamic approaches to examine the structure and relative stability of CoCu2O3 surfaces. Twenty-five surfaces along the [001], [010], [100], [011], [101], [110] and [111] low-Miller-indices, with varying surface-termination configurations were selected in this study. The results portray satisfactory geometrical parameters for bulk CoCu2O3, and a band gap of 1.25 e V. Furthermore, we clarified the stoichiometrically balanced inverted (010)CoCuO, and the non-stoichiometric (001)CuOCu, (001)CoOCo, (110)OCoO and (110)CoOCu surface terminations as the most stable configurations, out of which, the (001)CuOCu shows the optimum stability in ambient conditions. The systematic approach applied in this study should prove instrumental for the analysis of other 3-element multicomponent systems. To the best of our knowledge, the present study is the first to report DFT + U analysis to any 3-multicompnent systems with two of them requires inclusion of U treatment (i.e., f- and d- orbitals) in the electronic structure calculations.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Comparison between Rowatinex and Tamsulosin as a Medical Expulsion Therapy for Ureteral Stone
...Show More Authors

The objective of this study is to evaluate the efficacy and safety of rowatinex and tamsulosin in the treatment of patients with ureteric stone.

Forty patients with ureteric stone ranged (4- 12) mm, were included in this study. They were randomized into two groups where the first group includes twenty patients treated with Rowatinex three times daily (Group 1), and the second group includes twenty patients treated with tamsulosin 0.4mg/day (Group 2). All patients were randomly assigned to receive the designed standard medical therapy for a maximum of 3 weeks.

Each group was given an antibiotic as prophylaxis and an injectable non-steroidal anti-inflammatory drug used on demand. At the outpatient clinic all subjects were a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 28 2019
Journal Name
Iraqi Journal Of Science
Dynamics and an Optimal Policy for A Discrete Time System with Ricker Growth
...Show More Authors

The goal of this paper is to study dynamic behavior of a sporadic model (prey-predator). All fixed points of the model are found. We set the conditions that required to investigate the local stability of all fixed points. The model is extended to an optimal control model. The Pontryagin's maximum principle is used to achieve the optimal solutions. Finally, numerical simulations have been applied to confirm the theoretical results.

View Publication Preview PDF
Publication Date
Thu May 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Mammographic Doses Measurement for A Thick Compressed Breast and the Relationship Between Them
...Show More Authors

   This study was done in Baghdad teaching Hospital by using developed instrument type GIOHO and included a number of patients with compressed breast thickness (7,8,9,10)cm .

          The relationship between radiation dose and breast thickness was linear.  All results were compared with the international standered values that measured by the International Nuctear Agency and Europeon sources ,it was found that it is in consistance or has a little difference .

         The study showed that the mean absorbed dose may be determined by using TLD measurement below 10 mGy and the glandular dose was (1.45 mGy) and this can not b

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2013
Journal Name
Journal Of Computer Science
PROTOCOLS FOR SECURE ROUTING AND TRANSMISSION IN MOBILE AD HOC NETWORK: A REVIEW
...Show More Authors

Mobile ad hoc network security is a new area for research that it has been faced many difficulties to implement. These difficulties are due to the absence of central authentication server, the dynamically movement of the nodes (mobility), limited capacity of the wireless medium and the various types of vulnerability attacks. All these factor combine to make mobile ad hoc a great challenge to the researcher. Mobile ad hoc has been used in different applications networks range from military operations and emergency disaster relief to community networking and interaction among meeting attendees or students during a lecture. In these and other ad hoc networking applications, security in the routing protocol is necessary to protect against malic

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (5)
Scopus Crossref
Publication Date
Wed Jan 26 2022
Journal Name
Iraqi Journal Of Science
A Mathematical Model for Iraqi Airways Company about Evaluating Its Objectives and Strategies
...Show More Authors

In this paper, we introduced a mathematical model for Iraqi Airways Company about evaluating its objectives and strategies. First, we studied Iraqi Airways schedules with different departure cities for each airline path. Then, we applied some fuzzy integrals for determining the best airline path.

View Publication Preview PDF
Publication Date
Mon Dec 02 2013
Journal Name
Iraqi Medical Journal
Etiology and Antibiotic Sensitivity for Otitis Media in A Central Pediatric Teaching Hospital.
...Show More Authors

Publication Date
Thu Jun 01 2023
Journal Name
2023 Ieee 36th International Symposium On Computer-based Medical Systems (cbms)
Toward a Minimal sEMG Setup for Knee and Ankle Kinematic Estimation during Gait
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
Deep Learning-Based Segmentation and Classification Techniques for Brain Tumor MRI: A Review
...Show More Authors

Early detection of brain tumors is critical for enhancing treatment options and extending patient survival. Magnetic resonance imaging (MRI) scanning gives more detailed information, such as greater contrast and clarity than any other scanning method. Manually dividing brain tumors from many MRI images collected in clinical practice for cancer diagnosis is a tough and time-consuming task. Tumors and MRI scans of the brain can be discovered using algorithms and machine learning technologies, making the process easier for doctors because MRI images can appear healthy when the person may have a tumor or be malignant. Recently, deep learning techniques based on deep convolutional neural networks have been used to analyze med

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Feb 22 2025
Journal Name
Iraqi Journal Of Applied Physics
Effect of Gas Mixing Ratio on Energy Band Gap of Mixed-Phase Titanium Dioxide Nanostructures Prepared by Reactive Magnetron Sputtering Technique
...Show More Authors

View Publication
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Preview PDF