EM International
The aim of this study is to the evaluation of the general hydrogeology condition of the Al-Khassa sub-basin area. Pumping test has been done for five wells in the area. The hydrogeological characteristics (transmissivity, hydraulic conductivity and storage coefficient) were determined in the area by input data which obtained from the pumping test process into the (AquiferWin32, Version 5) software program. The data were analyzed using Copper-Jacob, Theis and Hantuosh methods for pumping, the values of hydraulic characteristics range from: transmissivity (0.98 to 19.57) m²/day in (W7-W9-W10-W12) sites and 416 m²/day in W1, hydraulic conductivity (0.051 to 0.305) m/day in (W7-W9-W10-W12) sites and 5.012 m/day in W1, storage coefficie
... Show MoreHerbal remedies are used in induction of lactation. In view of that .Borage Officinalis was employed to ensure an abundant milk supply or rectify milk insufficiency .However, this remedy has not been scientifically tested .The animals were treated with the aqueous extract of Borage Officinalis flowers at a daily concentration of 100 mg / kg body weight /ml for each rat through Oro-gastric tube for 14 days. Animals were subdivided into subgroups according to their physiological status. Mammary glands of these animals were processed for histological, histochemical and immunohistochemical studies. Parameters indicated that the aqueous extract of Borage Officinalis flowers induced lactogenesis in the mammmary glands of virgin and pregnant rats
... Show MoreThe current study included testing the ability of plant Hydrilla verticillata (L. F.) on the accumulation of two heavy metals in its tissues, and use the plant in phytoremediation. The plant was exposure to different concentrations of chromium and copper metals (2.5, 5, 10, 15, 20) ppm, for a period of fourteen days, for each solution.The results showed that Hydrilla was more efficient in the removal of chromium, where the amount of the remaining concentration of chromium at the last day of the experiment was (0.20 ± 0.014- 0.66 ± 0.114- 0.99 ± 0.176- 0.79 ± 0.073- 1.80 ± 0.131) ppm, while for copper was (0.33 ± 0.06- 1.13 ± 0.39- 1.66 ± 0.05- 1.96 ± 0.043- 2.33 ± 0.0497) ppm at the last day of the experiment, respectively.
In this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption. No significant effect of initial Cd concentration on the removal efficiency of cadmium b
... Show MoreIn this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption. No significant effect of initial Cd concentration on the removal efficie
... Show More