Preferred Language
Articles
/
34YBtoYBIXToZYAL-LLU
Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study
...Show More Authors

The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air velocities were monitored concurrently in 10-min increments at each location. Further numerical and thermodynamical analyses of the measurements were conducted to reveal the influencing performance parameters. The highest temperature rises of air between the input and exit sections were determined as 12.3°C (January) and 17.2°C (June). It is found that the maximum values of effectiveness are 0.80 and 0.81, while coefficients of performance are 1.6 and 1.8 for January and June, respectively. It is also found that the EHX shows good functionality and effectiveness, with potential energy savings for equipment for cooling and heating under different weather conditions.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Design and Performance Investigation of a Solar- Powered Biological Greywater Treatment System in the Iraqi Climate
...Show More Authors

            The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to    residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 15 2025
Journal Name
Alustath Journal For Human And Social Sciences
Searching for Meaning in a Chaotic World: An Analysis of Tina Howe’s Birth and After Birth
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 13 2014
Journal Name
Journal Of Biotechnology Research Center
In Vivo Study for Measuring the Toxicity of Heat Stable Enterotoxin (a) Produced by Enterotoxigenic Escherichia coli in Mice
...Show More Authors

This research was conducted to measure the safety of heat stable enterotoxin a (STa) produced by enterotoxigenic Escherichia coli, through studying its toxic effect on mice since it showed a promising effect in reducing the proliferation of colorectal cancer cells. The cytogenetic effect was determined after giving five different doses (100, 200, 400, 800 and 1600)μg/Kg in comparison with negative (phosphate buffer saline / PBS) and positive (mitomycin C/ MMC, at doses of 2 and 5μg/Kg) controls on mouse bone marrow cells by employing the following parameters: mitotic index, chromosomal aberrations and micronucleus, also, the serum level of liver functional enzymes (GOT, GPT, ALP) was recorded. In addition, lethal dose 50 (LD 50) with cert

... Show More
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
A study the electrical properties of a Se:2.5%as thin films prepared by thermal cvaporation
...Show More Authors

thin films of se:2.5% as were deposited on a glass substates by thermal coevaporation techniqi=ue under high vacuum at different thikness

View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
A Five Variable Refined Plate Theory For Thermal Buckling Analysis Uniform And Nonuniform Of Cross-Ply Laminated Plates
...Show More Authors

This research is devoted to investigating the thermal buckling analysis behaviour of laminated composite plates subjected to uniform and non-uniform temperature fields by applying an analytical model based on a refined plate theory (RPT) with five unknown independent variables. The theory accounts for the parabolic distribution of the transverse shear strains through the plate thickness and satisfies the zero-traction boundary condition on the surface without using shear correction factors; hence a shear correction factor is not required. The governing differential equations and associated boundary conditions are derived by using the virtual work principle and solved via Navier-type analytical procedure to obtain critica

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Energy and Exergy Analysis of Dual Channel Solar Air Collector with Different Absorber Plates Geometry
...Show More Authors

Flat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I), dual channel with a smooth absorber plate (model II), dual channel with perforating “V” corrugated absorber plate (model III), dual channel with internal attached wire mesh (model Ⅳ), and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ). The dual channel collector used for

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Engineering
Parametric Study Of Laminar Free Convection In Horizontal Annulus With And Without Fins On The Inner Cylinder
...Show More Authors

View Publication
Publication Date
Wed Aug 19 2020
Journal Name
International Journal Of Research In Social Sciences And Humanities
HUMOUR IN THE AMERICAN AND BRITISH COMEDYEPISODES: A DISCOURSE ANALYSIS STUDY
...Show More Authors

DBNRAAK Mohammed, International Journal of Research in Social Sciences and Humanities, 2020

View Publication
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Effect of a Parked Car Orientation on a Temperature Distribution and Cooling Load Calculation: Experimental Study
...Show More Authors

When a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result

... Show More
View Publication Preview PDF
Crossref (2)
Crossref