Background: Primary healthcare in Egypt has undergone significant reforms since the 1990s, including the pioneering Family Health Program (FHP). However, limited evaluation exists regarding the FHP's impact on enhancing the delivery of primary healthcare services. The primary objective of this study was to analyze and understand the efficiency and effectiveness of the FHP in altering the delivery of primary healthcare in Egypt. We aimed to outline the fundamental characteristics of the primary healthcare system, compare them between the conventional and the newly reformed FHP centers, and gauge the awareness level of these variances among key decision-makers, focusing specifically on Cairo, Egypt. Methods: This cross-sectional study employed a mixed methods approach to evaluate and compare the quality of care between conventional clinics and FHP clinics in Cairo using the Consumer Assessment of Healthcare Providers and Systems (CAHPS) tool. The study population consisted of healthcare providers and municipal health authorities in Cairo. A purposive sampling method was used to select 19 FHP clinics and 12 conventional clinics, representing 75% of the total government primary care clinics in Cairo. Surveys were conducted among healthcare providers at these clinics, and interviews were conducted with 8 carefully selected municipal health authorities in supervisory roles. Descriptive statistics were used to summarize the survey responses. The chi-square (y2) test was employed to examine variations in scores between FHP and conventional clinics, with significance attributed to differences at the P < 0.05 level. Cronbach's alpha was used to assess the reliability of the scales used within each primary care dimension. Results: FHP clinics scored significantly higher on continuity of care (4.17 ± 0.37 vs. 3.68 ± 0.51, P = 0.05), family-centered approach (4.28 ± 0.59 vs. 2.97 ± 0.44, P = 0.01), and provider competency (4.29 ± 0.39 vs. 3.42 ± 0.99, P = 0.01) compared to conventional clinics. FHP clinics were more likely to offer domestic violence services (2.76 ± 1.49 vs. 1.80 ± 1.74, P = 0.02), tuberculosis treatment (2.73 ± 2.11 vs. 0.12 ± 0.34, P = 0.029), and prenatal care (4.75 ± 0.00 vs. 4.01 ± 1.56, P = 0.014). Conclusion: While FHP clinics demonstrate benefits in continuity, family-focus, and provider competency, quality improvements are still required in both conventional and FHP clinics to achieve comprehensive, continuous, integrated, and patient-centered primary healthcare aligned with community needs. Further evaluations are warranted given the continued expansion of the FHP program.
The present work covers the Face-Hobbing method for generation and simulation of meshing of Face hobbed hypoid gear drive. In this work the generation process of hobbed hypoid gear has been achieved by determination of the generation function of blade cutter. The teeth surfaces have been drawn depending on the simulation of the cutting process and the head cutter motion. Tooth contact analysis (TCA) of such gear drive is presented to evaluate analytically the transmission error function for concave and convex tooth side due to misalignment errors. TCA results show that the gear is very sensitive to misalignment errors and
the increasing of the gear teeth number decrease the transmission error for both concave and convex tooth sides a
Buckling analysis of composite laminates for critical thermal (uniform and linear) and mechanical loads is reported here. The objective of this work is to carry out theoretical investigation of buckling analysis of composite plates under thermomechanical loads, and experimental investigation under mechanical loads. The analytical investigation involved certain mathematical preliminaries, a study of equations of orthotropic elasticity for classical laminated plate theory (CLPT), higher order shear deformation plate theory (HSDT) , and numerical analysis (Finite element method), then the equation of motion are derived and solved using Navier method and Levy method for symmetric and anti-symmetric cross-ply and angle-ply laminated plates t
... Show MoreOne of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system wit
... Show MoreThe present study deals with the optimum design of self supporting steel communication towers. A special technique is used to represent the tower as an equivalent hollow tapered beam with variable cross section. Then this method is employed to find the best layout of the tower among prespecified configurations. The formulation of the problem is applied to four types of tower layout
with K and X brace, with equal and unequal panels. The objective function is the total weight of the tower. The variables are the base and the top dimensions, the number of panels for the tower and member's cross section areas. The formulations of design constraints are based on the requirements of EIA and ANSI codes for allowable stresses in the members
PMMA films of different thickness (0.006, 0.0105, 0.0206, 0.0385 and 0.056cm) were synthesized by casting process. The temperature and frequency dependence of dielectric constant and AC electrical conductivity measurements at various frequencies (10kHz-10MHz) and temperatures (293-373K) were carried out. Few anomalies in dielectric studies were observed near 313 and 373 K respectively. These points were related to glass transitions temperature. The variation of activation energy and conduction behavior was studied .From the AC conduction studies, it is confirmed that the mechanism responsible for the conduction process is hopping of carriers. The variations of the dielectric constant and loss as function of frequency at different tempera
... Show MoreBackground: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals
... Show MoreBackground: Knowledge about the prevalence and distribution of pathologies in a particular location is important when a differential diagnosis is being formulated. The aim of this study was to describe the prevalence and the clinicopathological features of odontogenic cysts and tumors affecting the maxilla and to discuss the unusual presentation of those lesions within maxillary sinus.
Materials and Methods: A multicenter retrospective analysis was performed on pathology archives of patients who were diagnosed with maxillary odontogenic cysts and tumors from 2010 to 2020. Data were collected with respect to age, gender and location.
Result: A total of 384 cases was identified, 320 (83.3%) cases were diagnosed as odontogenic
... Show MoreThis paper develops a nonlinear transient three-dimensional heat transfer finite element model and a rate independent three-dimensional deformation model, developed for the CO2 laser welding simulations in Al-6061-T6 alloy. Simulations are performed using an indirect coupled thermal-structural method for the process of welding. Temperature-dependent thermal properties of Al-6061-T6, effect of latent heat of fusion, and the convective and radiative boundary conditions are included in the model. The heat input to the model is assumed to be a Gaussian heat source. The finite element code ANSYS12, along with a few FORTRAN subroutines, are employed to obtain the numerical results. The benefit of the proposed methodology is that it
... Show More