Preferred Language
Articles
/
2xdkG5ABVTCNdQwCx4Ph
Combination of near-field and scattering effects in plasmonic perovskite solar cell including cobalt doped nickel oxide HTL
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jul 11 2019
Journal Name
Turkish Journal Of Pharmaceutical Sciences
<i>In Vitro</i> Macrophage Nitric Oxide and Interleukin-1 Beta Suppression by Moringa peregrina Seed
...Show More Authors

View Publication
Scopus (20)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Thu Apr 09 2020
Journal Name
Optoelectronics And Advanced Materials – Rapid Communications
Facile synthesis of Cu2FeSnSe4 nanoparticles for solar energy water splitting
...Show More Authors

Well-dispersed Cu2FeSnSe4 (CFTSe) nanoparticles were first synthesized using the hot-injection method. The structure and phase purity of as-synthesized CFTSe nanoparticles were examined by X-ray diffraction (XRD) and Raman spectroscopy. Their morphological properties were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The average particle sizes of the nanoparticles were about 7-10 nm. The band gap of the as-synthesized CFTS nanoparticles was determined to be about 1.15 eV by ultraviolet-visible (UV-Vis) spectrophotometry. Photoelectrochemical characteristics of CFTSe nanoparticles were also studied, which indicated their potential application in solar energy water splitting.

View Publication Preview PDF
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Al-khwarzmi Engineering Journal
Dynamic response analysis for the parabolic trough of solar collector
...Show More Authors

parabolic trough

Publication Date
Thu Sep 05 2019
Journal Name
Journal Of Advanced Research In Fluid Mechanics And Thermal Sciences
Thermal performance of different solar distillators under Iraq climate condition
...Show More Authors

In this work, a novel single-slope solar distillator of floating perforated absorber inserted with wicks (cotton ribbons), and a stepped distillator are designed and manufactured with the aim of developing the conventional distillator. They are examined experimentally at Baghdad, Iraq (33.3°N Latitude, 44.4°E Longitude) in order to enhance the freshwater productivity and the efficiency of the conventional distillator. Results showed that the daily productivity and efficiency of the stepped distillator are higher than that for conventional solar distillator by 30% and 36.19% respectively. The daily productivity and thermal efficiency for the distillator with the floating absorber are higher than that for the conventional distillator by 16%

... Show More
View Publication
Scopus (11)
Scopus
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
Numerical Study of Solar Chimney with Absorber at Different Locations
...Show More Authors

Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.

View Publication
Crossref (4)
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
2021 4th International Conference On Energy Conservation And Efficiency (icece)
Finite Element Modeling Of Finned Double-Pass Solar Air Heaters
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Numerical Simulation of Solar Granulation Dynamics Using Optical Correction Techniques
...Show More Authors

High-resolution imaging of celestial bodies, especially the sun, is essential for understanding dynamic phenomena and surface details. However, the Earth's atmospheric turbulence distorts the incoming light wavefront, which poses a challenge for accurate solar imaging. Solar granulation, the formation of granules and intergranular lanes on the sun's surface, is important for studying solar activity. This paper investigates the impact of atmospheric turbulence-induced wavefront distortions on solar granule imaging and evaluates, both visually and statistically, the effectiveness of Zonal Adaptive Optics (AO) systems in correcting these distortions. Utilizing cellular automata for granulation modelling and Zonal AO correction methods,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 16 2022
Journal Name
Clean Technologies
Performance Evaluation of Roughened Solar Air Heaters for Stretched Parameters
...Show More Authors

Crossref (5)
Crossref
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
Numerical Study of Solar Chimney with Absorber at Different Locations
...Show More Authors

Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.

View Publication Preview PDF
Crossref (4)
Crossref