Preferred Language
Articles
/
2xZ_vooBVTCNdQwC1aRL
Shell closures in Fl superheavy isotopes via determination of alpha decay preformation factor
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Economics And Administrative Sciences
Fuzzy Bridge Regression Model Estimating via Simulation
...Show More Authors

      The main problem when dealing with fuzzy data variables is that it cannot be formed by a model that represents the data through the method of Fuzzy Least Squares Estimator (FLSE) which gives false estimates of the invalidity of the method in the case of the existence of the problem of multicollinearity. To overcome this problem, the Fuzzy Bridge Regression Estimator (FBRE) Method was relied upon to estimate a fuzzy linear regression model by triangular fuzzy numbers. Moreover, the detection of the problem of multicollinearity in the fuzzy data can be done by using Variance Inflation Factor when the inputs variable of the model crisp, output variable, and parameters are fuzzed. The results were compared usin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 15 2023
Journal Name
Journal Of Interdisciplinary Mathematics
Some games via semi-generalized regular spaces
...Show More Authors

In this research, a new application has been developed for games by using the generalization of the separation axioms in topology, in particular regular, Sg-regular and SSg- regular spaces. The games under study consist of two players and the victory of the second player depends on the strategy and choice of the first player. Many regularity, Sg, SSg regularity theorems have been proven using this type of game, and many results and illustrative examples have been presented

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Synthesis of Ag/Au (core/shell) nanoparticles by laser ablation in liquid and study of their toxicity on blood human components
...Show More Authors
Abstract<p>Q-switch Nd: YAG laser of wavelengths 235nm and 1,460nm with energy in the range 0.2 J to 1J and 1Hz repetition rate was employed to synthesis Ag/Au (core/shell) nanoparticles (NPs) using pulse laser ablation in water. In this synthesis, initially the silver nano-colloid prepared via ablation target, this ablation related to Au target at various energies to creat Ag/Au NPs. Surface Plasmon Resonance (SPR), surface morphology and average particle size identified employing: UV-visible spectrophotometer, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The absorbance spectra of Ag NPs and Ag/Au NPs showed sharp and single peaks around 400nm and 410nm, respec</p> ... Show More
View Publication
Scopus (62)
Crossref (41)
Scopus Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Rapid Spectrophotometric Determination of Phenoxazine
...Show More Authors

A rapid high sensitive and inexpensive economic method has been developed for the Determination of phenoxazine by using molecular spectrophotometry. The method is based on the oxidation of phenoxazine by potassium (meta)periodate in acidic medium. The oxidation conditions were selected to enhance the sensitivity and the stability of the pink colored species which shows an absorption maximum at 530 nm. The Beer’s law was obeyed for phenoxazine concentration range from 1 to 6 µg mL-1 with 0.003 µg mL-1 detection limit and provided variation coefficients between 0.4 to 1.7 %. This method was successfully applied for the determination of phenoxazine in aqueous samples

View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets: Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets
...Show More Authors

The objective of this study is to determination the content of some heavy metals (lead, cadmium, chromium) in colored tattoo stickers. twelve kinds of colored tattoo stikcers were collected from Baghdad markets, it was estimated heavy metals using atomic absorption spectrophotometer (Shimadzu A5000). The results indicated the concentrations of lead in all samples (1.61_1.00 mg / kg) and chromium in the three samples (0.85_0.97 mg / kg) while other samples are free of chromium , and cadmium. These elements are the components of printing inks and dyes in tattoo stickers, and this does not conform to the health and safety conditions for the packaging of food according to the organizations of the health and safety of

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Evaluation of Fludarabine, and granulocyte colony stimulating factor in treatment of efractory/Relapsed Acute Leukemias in adult Iraqi patients
...Show More Authors

Background: Refractory/relapsed acute leukemia has always been a challenging problem for hematologist. Over the past decade emphasis has been made in the development of regimens containing fludarabine, combined with cytosine arabinoside for the treatment of refractory/relapsed acute leukemias. The aim of this study is to evaluate the efficacy and toxicity of the combination of fludarabine, high dose cytarabine, and granulocyte colony stimulating factor in refractory relapsed cases of acute leukaemia,
Methods: a prospective study is being conducted at the national center of hematology and hematology unit /Baghdad teaching hospital from July 2008 to July 2010.Twenty Patients with refractory/relapsed acute leukemia were treated with flud

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Potentiometric Determination of Iodide in Magnesium Fluoride by Iodide Electrode
...Show More Authors

Iodide Ø¢ in samples Ø¢ containing Ø¢ magnesium Ø¢ fluoride Ø¢ was Ø¢ determinedØ¢  Ø¢ by using iodide selective Ø¢ electrode. Ø¢ Detecting Ø¢ the limit for iodide determination

was around Ø¢ 5x1 oآ·5Ø¢ Ø¢ M with a standard Ø¢ deviation Ø¢ ranged Ø¢ from Ø¢ Ø¢Â± 0.3 to آ± 0.6.

QuantitativeØ¢  Ø¢ methodsØ¢  Ø¢ including; standard Ø¢ additionØ¢  Ø¢ method, Ø¢ Potentiometric

titration Ø¢ by using a Gran plot paper for an equivalent Ø¢ point determination and a Ø¢ directØ¢  Ø¢ methodØ¢&n

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Computers &amp; Mathematics With Applications
Simultaneous determination of time-dependent coefficients in the heat equation
...Show More Authors

View Publication
Scopus (39)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Spectrofluorimetric method for the determination of glibenclamide in pharmaceutical formulations
...Show More Authors

A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.

View Publication Preview PDF
Crossref