Human-computer interaction (HCI) is a field that has spurred a lot of study and research related to interface evaluation. According to experts in the field, it is an essential tool for spreading the notion that a computer's user interaction should resemble interpersonal interactions and free-form conversations. HCI researchers initially concentrated on enhancing the usability of various computer interfaces. This study conducted knowledge-based information preparation and evaluated the implementation of an online academic management system at the University of Baghdad using the effectiveness, time-based efficiency, and satisfaction rates after task questionnaire procedure. Twenty-four users participated in the usability testing to observe the system's performance. The findings show strong usability abilities, with a participation error rate of 33.3% and an effectiveness rate of 71.43%. Additionally, some recommendations are demonstrated for improving the human-computer interface metrics of our university system.
In addition to their high quantities of active chemicals, medicinal plants are well-known for their pharmacological qualities, which include immunological modulation. T Consequently, this study aimed to examine the effects of Avena sativa and Glycyrrhiza glabra leaf extracts on immunological responses as measured by blood cytokine and liver enzyme levels. The phytochemical analysis of Avena sativa crude leaf extracts revealed the presence of alkaloids,flavonoids, tannins, phenolic compounds, and saponins but the absence of resins and violet oils. On the other hand, violet oils, flavonoids, tannins, saponins, and glycosides were detected in significant concentration in Glycyrrhiza glabra ethanolic extract, although resins and phenolic compou
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli
The widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.
The present paper puts forward an enhancement for the throughput performance metric by p
... Show MoreKE Sharquie, AA Noaimi, GA Ibrahim, AS Al-Husseiny, Our Dermatology Online, 2016 - Cited by 3
The synthesis of ligands with N2S2 donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H2L1) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L2) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K2<
novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show More