Abstract
a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli
Dapagliflozin is a novel sodium-glucose cotransporter type 2 inhibitor. This work aims to develop a new
validated sensitive RP-HPLC coupled with a mass detector method for the determination of dapagliflozin, its
alpha isomer, and starting material in the presence of dapagliflozin major degradation products and an internal
standard (empagliflozin). The separation was achieved on BDS Hypersil column (length of 250mm, internal
diameter of 4.6 mm and 5-μm particle size) at a temperature of 35℃. Water and acetonitrile were used as
mobile phase A and B by gradient mode at a flow rate of 1 mL/min. A wavelength of 224nm was selected to
perform detection using a photo diode array detector. The method met the
The ï¤- Multiple mixing ratios of ï§-transitions from levels of 56Fe populated in 56 56 ( , ) Fe n n Fe ï§ ï‚¢ reactions are calculated by using const. S.T.M. This method has been used in other works [3,7] but with pure transition or with transitions that can be considered as pure transitionsØŒ in our work we used This method for mixed ï§ - transitions in addition to pure ï§ - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet ï¤- values. It is clear from the results that the ï¤- values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur
... Show MoreBackground: The present study aimed to assess the distribution, prevalence, severity of malocclusion in Baghdad governorate in relation to gender and residency Materials and Methods: A multi-stage stratified sampling technique was used in this investigation to make the sample a representative of target population. The sample consisted of 2700 (1349 males and 1351 females) intermediate school students aged 13 years representing 3% of the total target population. A questionnaire was used to determine the perception of occlusion and orthodontic treatment demand of the students and the assessment procedures for occlusal features by direct intraoral measurement using veriner and an instrument to measure the rotated and displaced teeth. Results a
... Show More