This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, and the harmonic load had a minor effect on the vibration amplitude. Adding fiber to LWAC improved its behavior and made the amplitude no more than 11.11%, corresponding to NWC. So, the response variance for the LWACF was approximately negligible compared with NWC. It is worth mentioning that the study produced a lightweight structure that resists harmonic vibrations with a small strength reduction by using LWACF as a deck-slab for cellular specimens and provides a structural element with a smaller density of about 27%, which presents an advantage for the cellular beam that is adopted for low-loaded structures.
The effect of considering the third dimension in mass concrete members on its cracking behavior is investigated in this study. The investigation includes thermal and structural analyses of mass concrete structures. From thermal analysis, the actual temperature distribution throughout the mass concrete body was obtained due to the generation of heat as a result of cement hydration in addition to the ambient circumstances. This was performed via solving the differential equations of heat conduction and convection using the finite element method. The finite element method was also implemented in the structural analysis adopting the concept of initial strain problem. Drying shrinkage volume changes were calculated using the procedure suggested
... Show MoreIn the recent years, some of the newly constructed asphalt concrete pavements in Baghdad as well as other cities across Iraq showed premature failures with consequential negative impact on both roadway safety and economy. Frequently, load associated mode of failure (rutting and fatigue) as well as, occasionally, moisture damage in some poorly drained sections are the main failure types found in those newly constructed road.
In this research, hydrated lime was introduced into asphalt concrete mixtures of wearing course in two methods. The first one was the addition of dry lime on dry aggregate and the second one was the addition of dry lime on saturated surface dry aggregate moisturized by 2.0 to 3.0 percent of wa
... Show MoreThe effect of considering the third dimension in mass concrete members on its cracking behavior is investigated in this study. The investigation includes thermal and structural analyses of mass concrete structures. From thermal analysis, the actual temperature distribution throughout the mass concrete body was obtained due to the generation of heat as a result of cement hydration in
addition to the ambient circumstances. This was performed via solving the differential equations of heat conduction and convection using the finite element method. The finite element method was also implemented in the structural analysis adopting the concept of initial strain problem. Drying shrinkage volume changes were calculated using the procedure sug
In order to evaluate the performance of introduced varieties of maize and test them under different levels of plant density, and to determine which of the introduced varieties give a high yield and at what plant density, a field experiment was carried out at Station A in the Department of Field Crops- College of Agricultural Engineering Sciences - University of Baghdad- Jadiriyah, for the fall season 2021, the RCBD design was used with four replications, in a split plot arrangement, the three plant densities (50.000, 70.000, and 90.000 Plant s ha-1) were the main plates, while the varieties represented the secondary factor, which is six varieties of maize, class 2 = 5783 DKC, Class 3 = 6315 DKC, Class 4= 6590 DKC, whic
... Show MoreBackground: The aim of this study was to evaluate the effect of three types of light curing devices QTH, LED and Flashmax on the surface microhardness of three types of bulkfill composite resins; Filtek Bulkfill posterior composite ( 3M), Tetric Evo Ceram ( Ivoclar Vivadent) and Sonicfill composite ( Kerr) Materials and methods: Total number of 90 samples was prepared, 30 samples for each type of bulkfill composite, were divided into three main groups, group A: Filtek posterior bulkfil (3M), group B: Tetric Evo Ceram (Ivoclar Vivadent) and group C: contain Sonicfill composite (kerr). Which then divided into three subgroups (n= 10) (1) Samples cured by QTH system (2) Samples cured by LED system and (3) samples cured by Flashmax system the
... Show MoreBackground: Periodontal diseases are inflammatory disorders caused by the accumulation of oral biofilm and the host response to this accumulation which characterized by exaggerated leukocytes and neutrophils attraction to the sites of inflammation by chemoattractants which are a very important part of the pathogenesis of periodontal diseases. This study aimed to determine and compare the clinical periodontal parameters and the leukocyte cell types in the peripheral blood between patients with gingivitis and periodontitis with different severities compared to healthy controls. Materials and methods: This study included 150 male subjects aged between 35-50 years. They were divided into three groups: gingivitis group (n=30), periodontitis p
... Show MoreBackground: Plaque retention during fixed orthodontic therapy is an important cause of developing enamel demineralization. The purpose of this study was to evaluate the effect of different brackets types on the count of Streptococcus Mutans in orthodontic patients using conventional fluoridated toothpaste. Materials and Methods: Plaque samples were collected from maxillary 1st premolar teeth of twenty right handed patients (using split mouth technique) before bonding, after 48 hrs of bonding using tooth brush only, and after 2 weeks of using fluoridated toothpaste. Stainless steel bracket was bonded on right first premolar while the left one was bonded with sapphire bracket. The calculation of the Streptococcus Mutans count was done usin
... Show More