Experimental and Numerical Analysis of Bubbles Distribution Influence in BubbleDeck Slab under Harmonic Load Effect
...Show More Authors

Reducing a structure’s self-weight is the main goal and a major challenge for most civil constructions, especially in tall buildings and earthquake-affected buildings. One of the most adopted techniques to reduce the self-weight of concrete structures is applying voids in certain positions through the structure, just like a voided slab or BubbleDeck slab. This research aims to study, experimentally and theoretically, the structural behavior of BubbleDeck reinforced concrete slabs under the effect of harmonic load. Tow-way BubbleDeck slab of 2500mm×2500m×200mm dimensions and uniformly distributed bubbles of 120mm diameter and 160mm spacing c/c was tested experimentally under the effect of harmonic load. Numerical analysis was also performed with the ABAQUS software. The results of the adopted numerical model were in acceptable agreement with the experimental results. The numerical analysis presented by the bubbles distribution effect was carried out for the BubbleDeck two-way slab under the effect of harmonic load through the evaluated numerical model. Two cases were considered in which the distribution kept the critical positions of the slab free from the bubbles. The results proved that bubbles distribution significantly affected the structural behavior.

Publication Date
Sat Apr 13 2024
Journal Name
Journal Of Optics
Analysis of laser induced breakdown spectra for distinguish between healthy and carious teeth
...Show More Authors

Dielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 05 2022
Journal Name
Baghdad Science Journal
Analysis of Fuel Burnup and Transmutations at High Burnup of Sodium Fast Breeder Reactor
...Show More Authors

In this paper, the Monte Carlo N-Particle extended  computer code (MCNP) were used to design a model of the European Sodium-cooled Fast Reactor. The multiplication factor, conversion factor, delayed neutrons fraction, doppler constant, control rod worth, sodium void worth, masses for major heavy nuclei, radial and axial power distribution at high burnup are studied. The results show that the reactor breeds fissile isotopes with a conversion ratio of 0.994 at fuel burnup 70 (GWd/T), and minor actinides are buildup inside the reactor core. The study aims to check the efficiency of the model on the calculation of the neutronic parameters of the core at high burnup.

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Design and Analysis of Electro-Hydraulic Servo System for Speed Control of Hydraulic Motor
...Show More Authors

In this study, the electro-hydraulic servo system for speed control of fixed displacement hydraulic motor using proportional valve and (PID) controller is investigated theoretically ,experimentally and simulation . The theoretical part includes the derivation of the nonlinear mathematical model equation of (valve – motor ) combination system and the derivation of the transfer function for the complete hydraulic system , the stability test of the system during the operation through the transfer function using MATLAB package
V7.1 have been done. An experimental part includes design and built hydraulic test rig and simple PID controller .The best PID gains have been calculated experimentally and simulation, speed control performance te

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Spe Europec Featured At 81st Eage Conference And Exhibition
Development of Artificial Neural Networks and Multiple Regression Analysis for Estimating of Formation Permeability
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Apr 14 2017
Journal Name
Mechanical Engineering
Testing a Locally Assembled Combine Implement Used for Open Furrow, Planting and Fertilizing under Different Machinery Unit Speeds
...Show More Authors

Preview PDF
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Educational And Psychological Researches
Analysis of Palestinian Ministry of Education Test Results in Mathfor Eighth Graders basic Public Schools in Tulkarm
...Show More Authors

هدفت هذه الدراسة إلى تحليل نتائج الاختبار الوطني الموحد الذي تطبقه وزارة التربية والتعليم الفلسطينية في مادة الرياضيات لطلبة الصف الثامن الأساسي في المدارس الحكومية في محافظة طولكرم، وذلك لمعرفة مستوى الطلبة على هذا الاختبار في ضوء متغيرات الجنس والمنطقة التعليمية ونوع المدرسة، ومعرفة علاقة التحصيل على هذا الاختبار بتحصيل الطلبة المدرسي والمعدل العام. ولتحقيق ذلك تم تحليل درجات (3218) طالباً وطالبة؛ وهم ي

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 03 2022
Journal Name
Arabian Journal For Science And Engineering
Experimental Study of Cuttings Transport Efficiency of Low Solid Bentonite Drilling Fluids Modified by Cellulose Nanoparticles
...Show More Authors

Advancements in horizontal drilling technologies are utilized to develop unconventional resources, where reservoir temperatures and pressures are very high. However, the flocculation of bentonite in traditional fluids at high temperature and high pressure (HTHP) environments can lower cuttings transportation efficiency and even result in problems such as stuck pipe, decreased rate of penetration (ROP), accelerated bit wear, high torque, and drag on the drill string, and formation damage. The major purpose of the present research is to investigate the performance of low bentonite content water-based fluids for the hole cleaning operation in horizontal drilling processes. Low bentonite content water-based drilling fluids were formulated by re

... Show More
Crossref (7)
Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Sustainability
Experimental Evaluation of the Thermoelectrical Performance of Photovoltaic-Thermal Systems with a Water-Cooled Heat Sink
...Show More Authors

A design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i

... Show More
View Publication
Scopus (31)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref