Preferred Language
Articles
/
2BenkpABVTCNdQwCDo1e
Study of the Effect of Ce <sup>3+</sup> on the Gas Sensitivity and Magnetic Properties of Cu<sub>x</sub>Ce<sub>0.3-X</sub>Ni<sub>0.7</sub>Fe<sub>2</sub>O<sub>4</sub> Ferrite Nanoparticles
...Show More Authors

This study includes the preparation of the ferrite nanoparticles CuxCe0.3-XNi0.7Fe2O4 (where: x = 0, 0.05, 0.1, 0.15, 0.2, 0.25, 0.3) using the sol-gel (auto combustion) method, and citric acid was used as a fuel for combustion. The results of the tests conducted by X-ray diffraction (XRD), emitting-field scanning electron microscopy (FE-SEM), energy-dispersive X-ray analyzer (EDX), and Vibration Sample Magnetic Device (VSM) showed that the compound has a face-centered cubic structure, and the lattice constant is increased with increasing Cu ion. On the other hand, the compound has apparent porosity and spherical particles, and there are no other elements other than those participating in the preparation of the compound, which means that it is of high purity. The prepared compound possesses excellent magnetic properties due to the narrowness of the magnetic hysteresis ring. The gas sensing system found that the compound has good sensitivity to H2S gas.

Scopus Crossref
View Publication
Publication Date
Mon Sep 10 2018
Journal Name
Iraqi Journal Of Physics
The influence of magnetic field and cathode dimensions on plasma characteristics in hollow cathode system
...Show More Authors

Experimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 30 2025
Journal Name
International Journal Of Environmental Impacts
Analysis of the Effect of Heavy Elements in Polluted Industrial Water and its Environmental Treatment: An Applied Study on the Gas Power Plant/ 1 (Central Region) in Southern Baghdad and its Discharge into the Tigris River
...Show More Authors

Water produced from power plants is one of the most important sources of water pollution, especially for areas like Baghdad, Contaminated industrial wastewater is a major environmental challenge due to the rapid growth of industries, leading to increased accumulation of harmful pollutants in water resources, the work is intended to study the impact of water generated from a power plant in the south on the level of heavy metals before and after the treatment process and after its discharge to the Tigris River. Objective is to determine the extent of heavy metals such as iron, copper, chromium, and zinc concentration in water extracted from various points and subsequently study the monthly variations of these elements with a view to assessmen

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of SOLO and sodium hypochlorite disinfectant on some properties of different types of dental stone
...Show More Authors

Background: Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 15 2013
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of SOLO and sodium hypochlorite disinfectant on some properties of different types of dental stone
...Show More Authors

Background: Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60

... Show More
Preview PDF
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of SOLO and Sodium Hypochlorite Disinfectant on Some Properties of Different Types of Dental Stone
...Show More Authors

Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60 test block w

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Journal Of Taibah University Medical Sciences
Cytotoxic properties of Pelargonium graveolens leaf extract and its green-synthesized gold nanoparticles (in vitro study)
...Show More Authors

View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Effect of BaTio3 mixture on the structural, electrical properties and morphology for PET/ BaTiO3 composite
...Show More Authors

In the present work, the focusing was on the study of the x-ray diffraction, dielectric constant, loses dielectric coefficient, tangent angle, alter- natively conductivity and morphology of PET/BaTio3. The PET/BaTio3 composite was prepared for polyethylene terephthalate PET polymer composite containing 0, 10, 20, 30, 40, 50, and 60 wt. % from Barium titanate BaTi03 powder. The composite of two materials leads to form mixing solution and hot-pressing method. The effect of BaTio3 on the structure and dielectric properties with morphology was studied on PET matrix polymer using XRD, LCR meter and SEM.

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Oct 30 2023
Journal Name
Digest Journal Of Nanomaterials And Biostructures
Concentration effect on the vibrational and electronic properties of MgXZn7-XO7 wurtzoids nanostructure via DFT
...Show More Authors

In the present work, the ternary compound MgxZn7-x O7Wurtzoid with variable Zn and Mg contents was analyzed using density functional theory with B3LYP 6-311G**basis set. The electronic and vibrational properties of MgxZn7-xO7 wurtzoids, were investigated, including energy gaps, bond lengths, spectral properties, such like infrared spectra and Raman. IR and Raman spectra were compared with experimental longitudinal optical modes frequency results. The theoretical results agree well with experiments and previous data. It has been found that the energy gap is increasing with the increased Mg concentration, and that the longitudinal optical position exposes a UV shift movement with an increase in the concentration.

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Mar 06 2016
Journal Name
Baghdad Science Journal
Investigation of the dielectric Properties of (PPAB) terminated by phenylenediamine doped by Na2[Fe(CN)5.NO].2H2O using Lumped equivalent circuit
...Show More Authors

The aim of this paper is to demonstrate the effect of Na2[Fe(CN)5.NO].2H2O impurity (0.1 M) concentration on the dielectrical properties of poly (P-Aminobenzaldehyde) terminated by pheneylenediamine in the frequency and temperature ranges (1-100)KHz and (283-348) K respectively.These properties include dissipation factor, series and parallel resistance, series and parallel capacitance, real and imaginary part of the dielectric constant, a.c conductivity and impedance (real and imaginary) part, that have been deduced from equivalent circuit. The investigation shows that adding Na2[Fe(CN)5.NO].2H2O as additive to the polymer lead to increase of the dielectric constant with increasing temperature and it is decreasing with increasing the freq

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Enhancement of functionalized carbon nanotubes gas sensor by adding metal oxide nanoparticles
...Show More Authors

Functionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p

... Show More
View Publication Preview PDF
Crossref (6)
Crossref