Preferred Language
Articles
/
1xjsfpUBVTCNdQwCNy62
Microleakage Evaluation of a Silorane-Based and Methacrylate-Based Packable and Nanofill Posterior Composites (in vitro comparative study)
...Show More Authors

This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were then thermocycled, immersed in 1% methylene blue dye for 24 hours at room temperature, embedded in auto-polymerizing acrylic resin and sectioned longitudinally bucco-lingually. Microleakage was evaluated by assessing the linear dye penetration at the tooth/restoration interface occlusally and gingivally. The highest microleakage score occlusally or gingivally was recorded and the results were analyzed statistically using SPSS version 13. The results of this study showed that the silorane-based posterior composite Filtek™ P90 showed significantly less microleakage than the methacrylate-based packable composite (Filtek™ P60) and the nano-filled composite (Filtek™ Supreme XT) when the tooth-restoration interface is located in enamel.

Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Oral And Maxillofacial Surgery
Characteristics of mandibular injuries caused by bullets and improvised explosive devices: a comparative study
...Show More Authors

The purpose of this study was to investigate the difference in mandibular trauma caused by two mechanisms for the delivery of missile injuries: firearms and improvised explosive devices (IEDs). The data investigated included sex, age, mechanism of injury, and other clinical and radiographic manifestations. Seventy consecutive patients, predominantly male, with a mean age of 28.6 ± 14 years (range 2–60 years) were enrolled: 38 patients (54.3%) sustained mandibular fractures caused by bullet injuries and 32 patients (45.7%) had mandibular fractures caused by IED explosion injuries. The study revealed that the differences in most of the investigated variables were not statistically significant; the only significant differences were the inci

... Show More
View Publication
Scopus (9)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Synthesis, Characterizations, and Recent Applications of the Silica-based Mobil Composition of Mesoporous Material: A Review
...Show More Authors

Silica-based mesoporous materials are a class of porous materials with unique characteristics such as ordered pore structure, large surface area, and large pore volume. This review covers the different types of porous material (zeolite and mesoporous) and the physical properties of mesoporous materials that make them valuable in industry. Mesoporous materials can be divided into two groups: silica-based mesoporous materials and non-silica-based mesoporous materials. The most well-known family of silica-based mesoporous materials is the Mesoporous Molecular Sieves family, which attracts attention because of its beneficial properties. The family includes three members that are differentiated based on their pore arrangement. In this review,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jul 02 2020
Journal Name
Jasep المجلة العربية للعلوم التربوية والنفسية
Critical Thinking-Based Learning: Developments, Trends, and Values
...Show More Authors

In recent years, English language teaching and second language acquisition has demonstrated a significant accentuation upon basic reasoning abilities improvement in the language capability advancement. Encouraging a point of view of duty to training basic intuition aptitudes in accordance with the English language courses, this paper gives an account of an investigation directed at theoretical meanings of basic deduction, drifts about the centrality of basic speculation for language educating and associations between critical thinking and language learning. The educators have the focal pretended by basic intuition in successful language teaching method, identified to Ennis’ (2011) critical thinking categories. The skill of thinking critic

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
COMPUTER-BASED ECG SIGNAL ANALYSIS AND MONITORING SYSTEM
...Show More Authors

This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagno

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 11 2022
Journal Name
Electronics
IoT-Based Motorbike Ambulance: Secure and Efficient Transportation
...Show More Authors

The predilection for 5G telemedicine networks has piqued the interest of industry researchers and academics. The most significant barrier to global telemedicine adoption is to achieve a secure and efficient transport of patients, which has two critical responsibilities. The first is to get the patient to the nearest hospital as quickly as possible, and the second is to keep the connection secure while traveling to the hospital. As a result, a new network scheme has been suggested to expand the medical delivery system, which is an agile network scheme to securely redirect ambulance motorbikes to the nearest hospital in emergency cases. This research provides a secured and efficient telemedicine transport strategy compatible with the

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Evaluation of Risk Management among Managers of the Primary Health Care Centers in Baghdad City: Comparative Study
...Show More Authors

Background: Several risk managem-ent standards had been developed including the Project Management Institute, the National Institute of Standards and Technology, actuarial societies, and ISO standards.

Objective: The study aimed at evaluating risk management among managers of model and ordinary primary health care centers in Baghdad City and comparing the risk management among these centers.

Methods: A descriptive comparative des

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 06 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and In- Vitro Evaluation of Spherical Crystal Agglomerates of Ebastine by Quasi Emulsion Solvent Diffusion Method
...Show More Authors

Ebastine (EBS) is a poorly water-soluble antihistaminic drug; it belongs to the class II group according to the biopharmaceutical classification system (BCS). The aim of the present work was to enhance the solubility, dissolution rate and micromeritic properties of the drug, by formulating it as spherical crystal agglomerates by Quasi Emulsion Solvent Diffusion (QESD) method.

Spherical crystal agglomerates (SCAs) were prepared in presence of three solvents dichloromethane (DCM), water and chloroform as a good solvent, poor solvent and bridging solvent respectively.  Agglomeration of EBS involved the use of some hydrophilic polymers like polyethylene glycol 4000 (PEG 4000), polyvinyl pyrrolidine K30 (PVP K30), D-?-tocopheryl

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Mon May 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of shifting the class I cavity position prepared in posterior teeth buccally and lingualy on stress distribution (Finite element analysis study)
...Show More Authors

Background: Rehabilitation of the carious tooth to establish tooth structure integrity required cavity design that show a benign stress distribution. The aim of this study was to investigate the influence of the cavity position on the stress values in the reamining tooth structure restored with amalgam or resin composite. Materials and methods: Seven 2-D models of maxillary first premolar include class I cavity design was prepared, one sound tooth (A) 3 composite (B1, B2, and B3) and 3 amalgam (C1, C2, and C3). In design (BI and C1) the cavity position is in the mid distance between bacc-lingual cusp tip, design (B2 and C2) and (B3 and C3) shifted toward the buccal cusp and the lingual cusp for 0.5 mm respectively. One hundred N vertical

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2024
Journal Name
Journal Of International Society Of Preventive And Community Dentistry
Effect of Incorporating Chitosan to Resin Modified Glass Ionomer Cement on Shear Bond Strength to Dentin (An In vitro Comparative Study)
...Show More Authors
A<sc>bstract</sc> <sec> <title>Aim:

Resin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This in vitro study evaluates the impact of chitosan, a biopolymer that is, both biomaterial and biocompatible, on the strength of dentin bonding and compares it with ACTIVA Bio-ACTIVE Restorative. The present study was aimed to assess the impact of including chitosan into Fuji II on the shear bond strength between. the restoration material and tooth dentin,

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref