This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were then thermocycled, immersed in 1% methylene blue dye for 24 hours at room temperature, embedded in auto-polymerizing acrylic resin and sectioned longitudinally bucco-lingually. Microleakage was evaluated by assessing the linear dye penetration at the tooth/restoration interface occlusally and gingivally. The highest microleakage score occlusally or gingivally was recorded and the results were analyzed statistically using SPSS version 13. The results of this study showed that the silorane-based posterior composite Filtek™ P90 showed significantly less microleakage than the methacrylate-based packable composite (Filtek™ P60) and the nano-filled composite (Filtek™ Supreme XT) when the tooth-restoration interface is located in enamel.
The subject of an valuation of quality of construction projects is one of the topics which it becomes necessary of the absence of the quantity standards in measuring the control works and the quality valuation standards in constructional projects. In the time being it depends on the experience of the workers which leads to an apparent differences in the valuation.
The idea of this research came to put the standards to evaluate the quality of the projects in a special system depending on quantity scale nor quality specifying in order to prepare an expert system “ Crystal “ to apply this special system to able the engineers to valuate the quality of their projects easily and in more accurate ways.
Background: The Titanium and its alloys are suitable for dental implant and medical applications. Biocompatibility of the materials is a major factor in determining the success of the implant and has a great impact on their rate of osseointegration. The aim of this study was to evaluate the biocompatibility and cytotoxicity of Ti2AlC in comparison to CPTi & Ti6Al7Nb in rabbits. Materials and Methods: 10 male New Zealand White rabbits, weighing (2-2.5 kg), aged (10-12 months) were used in this study. Cylindrical implants were prepared from the study materials (CPTi, Ti6Al7Nb and Ti2AlC) with (8mm) height and (3mm) diameter for the evaluation of tissue response and disc specimens were prepared with (6 mm) diameter and (2 mm) thickness for ev
... Show MoreAbstract: The article aimed to formulate an MLX binary ethosome hydrogel for topical delivery to escalate MLX solubility, facilitate dermal permeation, avoid systemic adverse events, and compare the permeation flux and efficacy with the classical type. MLX ethosomes were prepared using the hot method according to the Box–Behnken experimental design. The formulation was implemented according to 16 design formulas with four center points. Independent variables were (soya lecithin, ethanol, and propylene glycol concentrations) and dependent variables (vesicle size, dispersity index, encapsulation efficiency, and zeta potential). The design suggested the optimized formula (MLX−Ethos−OF) with the highest desirability to perform the
... Show MoreThe aim of our study was to investigate the antiviral activity of the Corchorus olitorius family Tiliaceae cultivated in Iraq against measles virus, and to demonstrate an overview about chemical constituents and pharmacological activity of Corchorus olitorius L.
About150 gm Leaves of Corchorus. olitorius were defatted by maceration in hexane for 24 hrs. The defatted plant materials were subjected for extraction after filtration using Soxhlet apparatus, with aqueous methanol 85% as a solvent extraction for 24 hours, the extract was filtered, and the solvent was evaporated under reduced pressure using a rotary evaporator to get a dry extract of about 12 gm. About 4 gm from the residue was suspended in 100
... Show MoreIn this paper, we employ the maximum likelihood estimator in addition to the shrinkage estimation procedure to estimate the system reliability (
As cities across the world grow and the mobility of populations increases, there has also been a corresponding increase in the number of vehicles on roads. The result of this has been a proliferation of challenges for authorities with regard to road traffic management. A consequence of this has been congestion of traffic, more accidents, and pollution. Accidents are a still major cause of death, despite the development of sophisticated systems for traffic management and other technologies linked with vehicles. Hence, it is necessary that a common system for accident management is developed. For instance, traffic congestion in most urban areas can be alleviated by the real-time planning of routes. However, the designing of an efficie
... Show MoreIn this work the effect of choosing tri-circular tube section had been addressed to minimize the end effector’s error, a comparison had been made between the tri-tube section and the traditional square cross section for a robot arm, the study shows that for the same weight of square section and tri-tube section the error may be reduced by about 33%.
A program had been built up by the use of MathCAD software to calculate the minimum weight of a square section robot arm that could with stand a given pay load and gives a minimum deflection. The second part of the program makes an optimization process for the dimension of the cross section and gives the dimensions of the tri-circular tube cross section that have the same weight of
... Show MoreBackground : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity
... Show More