Academic chemical laboratories (ACL) are considered public places the employees come in contact with a variety of pollutants. The aim of the current study was to detect heavy metals levels in the indoor air of ACL in two universities in Baghdad city and assess their levels in the academic employees’ scalp hair as biomarkers. Air samples inside ACL were collected to detect Fe, Cd, Zn, Pb and Cu. Scalp hair samples were collected from 40 adult chemical laboratory employees aged 30-60 years, who worked 5 days/week for 6 hours a day. Personal information relating to employees such as age, duration of exposure, smoking habit and sex, was collected as a questionnaire. The results of this study concluded that academic laboratory employees were exposed to high levels of heavy metals which was proven through the use of scalp hair; old ages, prolonged working periods, smoking habit have significant effects in increasing the levels of heavy metals in scalp hair, while the employees’ gender variation did not have a significant effect.
Albizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show MoreAlbizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show MoreThe goal of this research is to find the effects of both the studying students groupwhich has various educational levels and the integration of the fragmented information through or during the study of history subjects for the female students of the fifth secondary literary section.
To achieve this study or case the researcher has chosen an experimental design or test by studying three groups: two are as mentioned above and the third is just ordinary team. In addition to that, there is a test after the experiment. The researcher chose on purpose female students of the literal section from two different secondary school Al Asil and Wahran both are secondary school for girls, and both are from directorate of education- Al Karkh 2nd dist
This study aims to identify the impact of using the infrastructure of the Information Technology (IT) on the performance of human resources in the public universities. This process is done by doing research in the size, quality, and efficiency of the performance, also speed of achievement and simplification of procedures. Diyala University was chosen for the diagnosis through the opinions and attitudes of its employees. Consequently, suggestions that contribute to improve the performance of the employees and thus its overall performance are obtained. Another objective of this study is identifying the human resources which are currently used in academic institutions and educational services systems because the significant role of th
... Show MoreIn this work, varying compositions of SiO2 micro filler were added
with the Polyvinyl Chloride (PVC) and samples have been prepared
using film casting technique. The results have been analyzed and
compared for PVC samples with (1 wt%, 3 wt%, 5 wt% and 10 wt%)
SiO2 micro filler. Mechanical characteristics such as tensile strength,
elongation at break and Young`s modulus were measured for all the
samples, where the tensile strength was increased from 8.39 Mpa for
purified PVC to 16 Mpa for 3% SiO2/PVC composite. Also, thermal
conductivity measurement values illustrated that composite materials
have a good thermal insulation at 10 wt. %, thermal conductivity was
decreased from 0.1684 W/m.
This research aims to know the effectiveness of teaching with a proposed strategy according to the common Knowledge construction modelin mathematical proficiency among students of the second middle class. The researchers adopted the method of the experimental approach, as the experimental design was used for two independent and equal groups with a post-test. The experiment was applied to a sample consisting of (83) students divided into two groups: an experimental comprising (42) students and a control group, the second comprising (41) students., from Badr Shaker Al-Sayyab Intermediate School for Boys, for the first semester of the academic year (2021-2022), the two groups were rewarded in four variables: (chronological age calculated in mo
... Show MoreThis study was conducted to estimate some heavy metals cadmium, lead, nickel and iron in 15 samples of Iraqi honey with 3 replicates for each sample which were collected from apiaries near potential contamination areas in five Iraqi governorates, including Baghdad, Karbala, Babylon, Diyala and Salah al-Din. The atomic absorption technique was used to estimate the concentrations of heavy metals, the results showed that there were significant differences at (P≤0.05) between the concentrations of these elements in the honey samples, the highest concentrations of cadmium 0.123 mg/kg were recorded in Baghdad, near the petrochemical production complex, lead 4.657 mg/kg and nickel 0.023 mg/kg in Babylon near the power plant, iron was
... Show MoreDespite scholars’ attention on the typology of modality as a linguistic phenomenon, yet the use of modality across varieties of English is not well visible in communication-based researches that take semantics, pragmatics and discourse issues as the objects for their investigation. The paper generates its data from six M. A. dissertations from Nigerian University and equal number of the M. A. dissertations from Iraqi University to qualitatively and quantitatively investigate the contextual use of modality within the pragmatic perspective. The data analysis reveals that modality such as usuality, potentiality, necessity, probability and obligation in the dissertations encapsulates interpersonal and authorial voice in which the mean
... Show MoreHazardous materials, heavy metals, and organic toxins released into the environment have caused considerable harm to microbes, plants, animals, and humans. Wastewater is one of the most contaminated ecosystems due to heavy metals emitted mostly by human activity. Bioremediation of wastewater is an ecologically acceptable and cost-effective method of removing heavy metals from sewage; the general purpose of this study is to analyse the dependability of anaerobic sludge biomass in removing sulfur compounds and heavy metals from waste water. The anaerobic sludge biomass evaluated in this work was taken from a wastewater treatment plant (WWTP) in Al-Rustumiya, Baghdad, and grown in the mineral medium for anaerobic growth. In serum bottl
... Show MoreThe present study was invistigated to show the bioaccumulation of some heavy metals (Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Zn) by use Aquatic plant Myriophyllum verticilatum growing in Euphrates river between Spring 2004 to Winter 2005, and these heavy maters was studied in Dissolved and particulat phase of water and exchangable and residual phase of sediment. Heavy metals accumulated according the system water-sediment-aquatic plant, and recorded bioaccumulation factor 1.010, 0.005, 0.009, 0.011, 0.012, 0.010, 0.010, 0.010, 0.011, respectively.