Preferred Language
Articles
/
1xdZM48BVTCNdQwCdWCF
EFFECT OF OZONE ENRICHMENT AND SPRAYING WITH ORGANIC NUTRIENT ON NUTRIENT AND WATER USE EFFICIENCY AND FERTILIZER PRODUCTIVITY OF BROCCOLI PLANT CULTIVATED HYDROPONICALLY WITH MODIFIED NFT TECHNOLOGY.
...Show More Authors

This study was carried out at University of Baghdad - College of Agricultural Engineering Sciences - research station B during the fall season of 2019-2020, in order to evaluate the effect of Ozone enrichment and the foliar application of organic nutrient  on nutrient and water use efficiency and fertilizer productivity of broccoli plant using the modified NFT film technology. A factorial experiment (2*5) was carried out within Nested Design with three replicates. The ozone treatment was distributed into the main plots which consisted of oxygen (O2) and ozone (O3). The foliar application of organic nutrients were distributed randomly within each replicate including five treatments, which were the control treatment (T0), Coconut water with two concentrations of 50 (T1) and 100 ml. L-1 (T2), and Moringa leaves extract at two concentrations 2% (T3) and 4% T4. Results revealed a significant effect of ozone and the foliar application of coconut water 100 ml. L-1 at the treatment of O3T2 on the leaves content of N, P, and K, and vegetative dry weight, vegetative to roots dry weight ratio, the recovering efficiency of N, P, k, the use efficiency of N, P, K, and fertilizer productivity, reaching 4.530, 0.674, 3.139%, 178.81 g. Plant-1, 5.74, 8.21, 8.29, 8.68%, 65.17, 36.35, 24.48%, and 3.616 kg yield. Kg fertilizer, respectively, compared to the control treatment (O2T0). The treatment of ozone enrichment and the foliar application of 2% Moringa leaf extract (O3T3) or with coconut water 100 ml. L-1 (O3T2) gave a significant increment in plant yield reached 919.33 and 917.00 g. Plant-1 (O2T0) which gave the lowest plant yield reached 624.00 g. Plant-1.

Scopus Crossref
Publication Date
Sun Jun 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Understanding the Experience of Hospital Pharmacists with the Effectiveness, Safety, Adverse Drug Reaction Reporting and Interchangeability of Biopharmaceutical Medicines
...Show More Authors

The study objectives were to 1) explore the real-world experience of hospital pharmacists with the differences in effectiveness safety, and interchangeability between biosimilar medicines and their reference biological counterparts, 2) reveal pharmacist recommendations to enhance the safety of biopharmaceutical medicines in public hospitals.

The study has a mixed-method design where the core component was qualitative (interviews) and the supplemental component was quantitative (adverse drug reaction, ADR, reports). This qualitative component included semi-structured (mostly face-to-face) interviews involving hospital pharmacists from different hospitals with experience with biological or biosimilar medicines. The interviews were c

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
An evaluation of waste and well water quality for agriculture production around Erbil city, Iraq
...Show More Authors

Erbil city is located in the northern Iraq with a population of over one million people. Due to water crises farmers usually use wastewater and well water for the agricultural production. In this study six stations were designed to sample waste water and three from well water to define waste water and ground water characteristics. In this study, Residual Na+ Carbonate, Mg++ hazard, salinity hazard, Kelley index, %sodium, total hardness, permeability index, potential salinity, sodium adsorption ratio, and Irrigation Water Quality Index (IWQI) were determined. The order of average cation concentrations in water was Mg2+> Ca2+ > Na+ > K+. While the proportion of main

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Engineering
Estimation of Water and Energy Saving by Rainwater Harvesting: Sulaimani City as a Case Study
...Show More Authors

Rainwater harvesting could be a possible solution to decrease the consequences of water scarcity and energy deficiency in Iraq and the Kurdistan Region of Iraq (KRI). This study aims to calculate the water and energy (electricity) saved by rainwater harvesting for rooftops and green areas in Sulaimani city, KR, Iraq. Various data were acquired from different formal entities in Sulaimani city. Moreover, Google Earth and ArcMap 10.4 software were used for digitizing and calculating the total rooftop and green areas. The results showed that for the used runoff coefficients (0.8 and 0.95), the harvested rainwater volumes were 2901563 and 12197131 m³ during the study period (2005 – 2006) and (2019-2020). Moreover, by compa

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reverse Osmosis Polyamide Membrane for the Removal of Blue and Yellow Dye from Waste Water
...Show More Authors

The present work aims to study the removal of dyes from wastewater by reverse osmosis process. Two dyes were used direct blue 6, and direct yellow. Experiments were performed with feed concentration (75 – 450 ppm), operation temperature (30 – 50 oC) and time (0.2 – 2.0 hr). The membrane used is thin film composite membrane (TFC). It was found that modal permeate concentration decreases with increasing feed concentration and time operating, while permeate concentration increases with increasing feed temperature. Also it was found that product rate increase with increasing temperature, but it decrease with increasing feed concentration and time. The concentration of reject solution showed an increase with increasing feed concentratio

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering Science And Technology (jestec)
Water Quality Assessment and Sodium Adsorption Ratio Prediction of Tigris River Using Artificial Neural Network
...Show More Authors

Sodium adsorption ratio (SAR) is considered as a measure of the water suitability for irrigation usage. This study examines the effect of the physicochemical parameters on water quality and SAR, which included Calcium(Ca+2), Magnesium(Mg+2), Sodium (Na+), Potassium (K), Chloride (Cl-), Sulfate(SO4-2), Carbonate (CO3-2), Bicarbonate (HCO3-), Nitrate (NO3-), Total Hardness (TH), Total Dissolved Salts (TDS), Electrical Conductivity (EC), degree of reaction (DR), Boron (B) and the monthly and annually flow discharge (Q). The water samples were collected from three stations across the Tigris River in Iraq, which flows through Samarra city (upstream), Baghdad city (central) and the end of Kut city (downstream) for the periods of 2016-201

... Show More
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of NO2/N2O4 into Water and Dilute Nitric Acid in a Double Stirrer Adsorber
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering Science And Technology
Water quality assessment and sodium adsorption ratio prediction of Tigris River using artificial neural network
...Show More Authors

Publication Date
Thu Dec 01 2022
Journal Name
Int. J. Agricult. Stat. Sci.
STRAWBERRY CV. FESTIVAL GROWTH IN RESPONSES TO MAGNETIC WATER AND FOLIAR APPLICATION OF COCONUT EXTRACT
...Show More Authors

This study was carried out to study effect of magnetic water ( M0 and M) and different concentrations of coconut extract in Fragaria x ananassa (Duch) C.V Festival. The results showed significant differences in the plants treated with magnetic water ( 0.12 Tesla) and different concentrations of coconut extract C1 (0%), C2 (2.5%), C3 (5%), C4 (7.5%) and C5 (10%) in vegetative parameters as in leaf area and chlorophyll in treatment M0C3 was (53.72 Dcm2, 50.00), respectively, highest leaf number and plant dry weight in MC4 (12.77,14.22 gm), respectively. Results recorded significant differences in fruit parameters such as weight in MC1 (18.97 gm). The maximum fruit number was in MC3 (110), the greatest fruit size was in MC4 (15.78 cm3) and the

... Show More
View Publication
Scopus
Publication Date
Sun Jul 23 2023
Journal Name
Water
Evaluation of Water Quality Index (WQI) in and around Dhaka City Using Groundwater Quality Parameters
...Show More Authors

Groundwater quality deterioration due to anthropogenic natural activities and its immense utilization in various sectors is considered a great concern. The aim of this study is to determine the groundwater quality parameters at various sources in and around Dhaka city and compare them with Bangladesh drinking water standards. In this study, six groundwater quality parameters (pH, DO, COD, TS, TDS, and arsenic) and ten groundwater samples are analyzed to determine the water quality. The collected samples have maximum and minimum pH values of 6.9 and 6.4, respectively. Maximum and minimum DO values are 0.3 and 0.1 mg/L, respectively. The arsenic concentration is 0 mg/L for all collected groundwater samples. The maximum and minimum COD

... Show More
View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref