Preferred Language
Articles
/
1xcbMpIBVTCNdQwCX6cT
Comparison Between Conventional and Supersaturable Self-nanoemulsion Loaded with Nebivolol: Preparation and In-vitro/Ex-vivo Evaluation
...Show More Authors

Nebivolol (NBH) is a third-generation B1-blocker with high selectivity and vasodilation activity. Nevertheless, nebivolol exhibits low oral bioavailability, which may adversely affect its efficacy. Recently, supersaturable self-nanoemulsion (Su-SNE) is an advanced SNE approach that can address low bioavailability The study aims to prepare nebivolol-loaded Su-SNE by reduction the amount of the prepared conventional SNE to half. Besides, an appropriate polymer type and concentration to prevent NBH precipitation upon oral administration have investigated.. A conventional self-nanoemulsion (formula A) was prepared by dissolving NBH in 500 mg vehicle mixture of imwitor®988: cremophor-EL: propylene glycol. Then, eight Su-SNE formulas with the absence or presence of four different polymers were prepared and evaluated. In-vitro precipitation assay was performed to assess the precipitation inhibition capacity of polymers. The ex-vivo permeation through rat intestinal mucosa was also conducted for determination of permeability parameters. Results revealed that (Su-SNA formula SAS1) containing 5% soluplus could effectively retard the nebivolol precipitation. There was no statistical difference between formula A and SAS1; both maintained a higher apparent NBH concentra­tion for approximately 240 min in 0.1N HCl. The permeation rate of conventional (formula A) and soluplus-based Su-SNE (formula SAS1) was significantly improved, and the permeation enhancement ratio was found 2.7 and 3.2, respectively, as compared with non-formulated NBH. Consequently, it is concluded that developing soluplus-based nebivolol SNE is a promising alternative approach. It can enhance nebivolol stability and permeability with half the amount of conventional SNE components.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 01 2024
Journal Name
Results In Engineering
Electrochemical preparation and characterization of a new configuration SnO2 anode and its application for treating petroleum refinery wastewater
...Show More Authors

View Publication
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jan 09 2023
Journal Name
Indian Journal Of Economics And Business
Evaluation of reverse logistics options for international and local companies in Iraq
...Show More Authors

Many international companies have branches or agencies in Iraq and have large market shares, and this has contributed to the increase in the import of these companies' products. This process created an additional problem of handling a large number of expired or defective products. There are many methods that contribute significantly to reducing these problems. The most prominent of these is the activation of reverse logistics options in Iraq by international and local companies. This research aims to conduct a survey of the reverse logistics options approved by some local and international companies and compare between them. This paper found that Amaron, Hitachi, Apple, Samsung and Huawei have limited options for reverse logistics and that

... Show More
Publication Date
Mon Jan 01 2007
Journal Name
Iraqi Postgraduate Medical Journal
Therapeutic evaluation of spironolactone and finasteride in the treatment of acne vulgaris
...Show More Authors

S Khalifa E, AM Sabeeh A, AN Adil A, AW Ghassan H…, 2007

View Publication
Publication Date
Fri Oct 01 2010
Journal Name
Saudi Pharmaceutical Journal
Comparative clinical evaluation of ketotifen and montelukast sodium in asthmatic Iraqi patients
...Show More Authors

View Publication
Scopus (9)
Crossref (3)
Scopus Crossref
Publication Date
Wed Jun 24 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Sonographic evaluation of masseter muscle thickness in bruxist and non-bruxist subjects
...Show More Authors

Background: Masseter muscle is a jaw closing muscle of the mandible involved in Para functional habits; which include lip and cheek chewing, fingernail biting, and teeth clenching or bruxism which can be classified as awake or sleep bruxism. Patients with sleep bruxism are three to four times more likely to experience jaw pain and limitation of movement than people who do not experience sleep bruxism. The aim of this study is to measure the thickness of the masseter muscle in bruxist subjects and compare it with non-bruxist subjects by using sonography. Materials and Method: Forty Iraqi subjects with age ranged (20-40) divided into two groups according to the presence of bruxism. Clinical examination was made and masseter muscle thickness

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 22 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Sustained Release Sumatriptan Mucoadhesive Intranasal in-Situ Gel
...Show More Authors

    

Sumatriptan(ST) is a selective agonist at serotonin 5-HTI receptors, as well as 5-HT1B/1D subtypes. It is effective for acute migraine attacks, but has a short half  life (about 2 hours) and low oral bioavailability (15%). The purpose of this study was to develop and optimize nasal mucoadhesive in-situ gel(IG) of ST to enhance nasal residence time for migraine management. Cold method was used to prepare different formulas of  ST nasal IG, using thermosensitive polymers (poloxamer 407  alone or with poloxamer 188) with a mucoadhesive polymer hyaluronic acid (HA) which were examined for gelation temperature and gelation time, pH, drug content, gel strength, spreadability, muc

... Show More
View Publication Preview PDF
Scopus (42)
Crossref (25)
Scopus Crossref
Publication Date
Wed Jun 24 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of International Society Of Preventive And Community Dentistry
Investigating tensile bonding and other properties of yttrium oxide nanoparticles impregnated heat-cured soft-denture lining composite in vitro
...Show More Authors

Aims: This study was conducted to assess the effect of the addition of yttrium oxide (Y2O3) nanoparticles on the tensile bond strength, tear strength, shore A hardness, and surface roughness of soft-denture lining material. Materials and Methods: Y2O3 NPs with 1.5 and 2 wt.% were added into acrylic-based heat-cured soft-denture liner. A total of 120 specimens were prepared and divided into four groups according to the test to be performed (tensile bond strength, tear strength, surface hardness, and surface roughness). Results: There was a highly significant increase in tensile bond strength between the soft liner and the acrylic denture base, tear strength, and hardness at both concentrations as compared to the control group, whereas ther

... Show More
View Publication
Scopus (16)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Jan 11 2022
Journal Name
Journal Of Research In Medical And Dental Science | Vol. 10 | Issue 1 | January-2022
Esthetic Improvements of Various Degrees of White Spot Lesion Using Resin Infiltration and Micro-Abrasion (An In Vitro Study)
...Show More Authors

Background: White spot lesions are esthetic problems caused by subsurface enamel demineralization that seen as white opacity. Aim of the study: This study aimed to evaluate and to compare the color change after the treatment of the white spot lesions with resin ‹nϔ‹Žtrƒt‹on and micro abrasion. Materials and Methods: rt‹ϔ‹…‹ƒŽ white spot lesions were generated on 48 premolar teeth by the use of a demineralization solution. The teeth were randomly divided using the Diagnodent into three study groups (16 teeth for each group) depending on the depth of the induced lesions: outer enamel, inner enamel and outer dentine. Then each group was fatherly subdivided into two groups (8 teeth for each group) the ϔ‹rst group was treated wit

... Show More
Publication Date
Mon Apr 01 2024
Journal Name
Indian Journal Of Dental Research
Effect of Bisoctrizole on Ultraviolet (UV) Absorption Properties of Silicone and Effect on Surface Roughness - An In Vitro Study
...Show More Authors
Abstract<sec> <title>Background:

Premature degradation is the problem of maxillofacial silicones, significantly affected by ultraviolet exposure, contributing to silicones photodegradation. Degradation necessitates frequent replacement of prostheses that increase the total cost of rehabilitation.

Aims:

This study evaluated the effect of bisoctrizole on the ultraviolet absorption properties of silicone material and the stability of this absorption over time. Also, the bisoctrizole effect on the surface roughness of silicone was evaluated.

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref