Objective This study aims to investigate the impact of integrated training on kinematics variables and defensive accuracy in volleyball, focusing on enhancing balance and muscle tension control through proprioceptive neuromuscular facilitation (PNF) exercises. Methods The sample consisted of 14 male volleyball athletes from the first volleyball league of Al-Jaish Sports Club were divided into experimental (n=7) and control group (n=7). In the pre- and post-intervention periods, dynamic balance, muscle tension control and kinematic variables (during a lateral reaching task) as well as defensive performance accuracy upon fatigue onset of recoil laser strikes were assessed. Exposure the intervention program was carried out for six weeks, and the following measuring tools were used to assess performance, Y-Balance Test as well as sEMG and kinematic variables using Kinovea. Results Compared with the control- group, individuals in the experimental- group demonstrated significantly improved performance at balance (Y-Balance Test, Cohen's d = 1.42), muscle activity and tension control (sEMG, Cohen's d = 1.38) and defensive ability accuracy (Cohen's d = 1.60). Kinematic variables revealed moderate to large enhancements in knee, hip, shoulder, elbow ankle and trunk angles where effect size ranged from 1.03 to 1.49 (Cohen's d). Control group, as expected, showed mild changes in all studied variables. Conclusion The combined training program enhanced volleyball players’ biomechanical efficiency and defensive performance, highlighting its potential to boost performance, reduce injury risk, and improve coaching effectiveness.
Abstract
Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment
... Show MoreThe taxonomy of Ficus L., 1753 species is confusing because of the intense morphological variability and the ambiguity of the taxa. This study handled 36 macro-morphological characteristics to clarify the taxonomic identity of the taxa. The study revealed that Ficus is represented in the Egyptian gardens with forty-one taxa; 33 species, 4 subspecies and 4 varieties, and classified into five subgenera: Ficus Corner, 1960; Terega Raf., 1838; Sycomorus Raf., 1838; Synoecia (Miq.) Miq., 1867, and Spherosuke Raf.,1838; out of them seven were misidentified. Amongst, four new Ficus taxa were recently introduced to Egypt namely: F. lingua subsp. lingua Warb. ex De Wild. & T. Durand, 1901; F. pumila L., 1753; F. rumphii Blume, 1825, and F. su
... Show MoreThe goal of this work is to check the presence of PNS (photon number splitting) attack in quantum cryptography system based on BB84 protocol, and to get a maximum secure key length as possible. This was achieved by randomly interleaving decoy states with mean photon numbers of 5.38, 1.588 and 0.48 between the signal states with mean photon numbers of 2.69, 0.794 and 0.24. The average length for a secure key obtained from our system discarding the cases with Eavesdropping was equal to 125 with 20 % decoy states and 82 with 50% decoy states for mean photon number of 0.794 for signal states and 1.588 for decoy states.
In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio
... Show MoreCase Report.
To present a case of a previous complicated mandibular orthognathic surgery that aimed to setback the mandible in a female cleft lip and palate (CLP) patient, which led to bone necrosis on one side with subsequent severe mandibular deviation and facial asymmetry. We additionally reviewed the previous reports of similar complications, the pathophysiology and the factors that could lead to this dreadful result.
A 27-year-old female patient presented with a severe dentofacial deformity secondary to a complicated bilateral sagittal spli