Preferred Language
Articles
/
1heBbI4BVTCNdQwC-Eed
Ability of FeNi3/SiO2/TiO2 nanocomposite to degrade amoxicillin in wastewater samples in solar light-driven processes
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jun 26 2021
Journal Name
Journal Of Engineering
Adsorption Desulfurization of Iraqi Light Naphtha Using Metals Modified Activated Carbon
...Show More Authors

The study aims to evaluate the removal of sulfur content from Iraqi light naphtha produced in Al-Dora refinery by adsorption desulfurization DS technique using modified activated carbon MAC loaded with nickel Ni and copper Cu as single binary metals. The experiments were carried in a batch unit with various operating parameters;  MAC dosage, agitation speed, and a contact time of 300 min at constant initial sulfur concentration 155 ppm and temperature. The results showed higher DS% by AC/Ni-Cu (66.45)% at 500 rpm and 1 g dosage than DS (29.03)% by activated carbon AC, increasing MAC dosage, agitation speed, and contact time led to increasing DS% values.  The adsorption capacity of MAC results was recorded (16, 15, and 20) mg sulfu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Responsivity of porous silicon for blue visible light with high sensitivity
...Show More Authors

In this work, porous silicon (PS) are fabricated using electrochemical etching (ECE) process for p-type crystalline silicon (c-Si) wafers of (100) orientation. The structural, morphological and electrical properties of PS synthesized at etching current density of (10, 20, 30) mA/cm2 at constant etching time 10 min are studied. From X-ray diffraction (XRD) measurement, the value of FWHM is in general decreases with increasing current density for p-type porous silicon (p-PS). Atomic force microscope (AFM) showed that for p-PS the average pore diameter decreases at 20 mA. Porous silicon which formed on silicon will be a junction so I-V characteristics have been studied in the dark to calculate ideality factor (n), and saturation current (Is

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Apr 13 2020
Journal Name
International Journal Of Research Inpharmaceutical Sciences
The UV light effects on pectinase production of Pantoea sp. bacteria
...Show More Authors

Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
A simple voice communication using the modulation of the reflected light
...Show More Authors

There is no adopt in the importance of the optical communications in scientific civil and military applications because of it’s simplicity in manufacturing and it's low cost. The method of optical communication depends upon bearing the light beam the translated informations by a method called the light modulation. This method depends upon changing some light properties as frequency, amplitude and pulse duration according to the translating informations. The changes in the first two properties are concerned optically with the analog modulation while the third one concern at most with digital modulation. All past methods are expensive with low efficiency and needs electrical or magnetic fields. In this technique the source of voice used

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 26 2021
Journal Name
Journal Of Engineering
Adsorption Desulfurization of Iraqi Light Naphtha Using Metals Modified Activated Carbon
...Show More Authors

The study aims to evaluate the removal of sulfur content from Iraqi light naphtha produced in Al-Dora refinery by adsorption desulfurization DS technique using modified activated carbon MAC loaded with nickel Ni and copper Cu as single binary metals. The experiments were carried in a batch unit with various operating parameters;  MAC dosage, agitation speed, and a contact time of 300 min at constant initial sulfur concentration 155 ppm and temperature. The results showed higher DS% by AC/Ni-Cu (66.45)% at 500 rpm and 1 g dosage than DS (29.03)% by activated carbon AC, increasing MAC dosage, agitation speed, and contact time led to increasing DS% values.  The adsorption capacity of MAC results was recorded (16,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Parabolic Trough Solar Collector – Design, Construction and Testing
...Show More Authors

This paper presents the design, construction and investigates an experimental study of a parabolic Trough Solar Collector (PTSC). It is constructed of multi – piece glass mirror to form the parabolic reflector (1.8 m ? 2.8 m) its form were checked with help of a laser and carbon steel rectangular as receiver. Sun tracker has been developed (using two – axis) to track solar PTSC according to the direction of beam propagation of solar radiation. Using synthetic oil as a heat transfer its capability to heat transfer and load high temperature (?400 oc). The storage tank is fabricated with stainless steel of size 50 L. The experimental tests have been carried out in Baghdad climatic conditions (33.3o N, 44.4o E) during selective days of the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 04 2021
Journal Name
Journal Of Coastal Conservation
Solar system planetary alignment triggers tides and earthquakes
...Show More Authors

View Publication
Scopus (5)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
...Show More Authors

The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that cause global warming and greenhouse effect. Flat plate collector was used because it’s easy, ninexpensive and efficient. Many test runs (more than 50) were carried out on the system from May to October, 2013; the main results were taken between the period of July 15, 2013 to August 15, 2013 to find the maximum C.O.P, cooling, temperature and pressure of the system. The system demonstrates a maximum generator temperature of 93.5 oC, on July 18, 2013 at 2:30 pm, and the average mean generator temperature Tgavr was 74.7 °C, for this period. The maximum pressure Pg

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 29 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of the auditor in measuring social and environmental performance indicators in light of the implementation of the GRI standards: (Applied research at the Iraqi General Cement Company)
...Show More Authors

This study measures the indicators of social and environmental performance of the contents of the administration's prepared reports on its social and environmental performance by comparing the actual performance with the indicators set within the standards of the Global Reports Initiative (GRI), In preparing this research, the researchers relied on studying the criteria of the Global Reporting Initiative, which aims to achieve a high level of performance disclosure under sustainability, In light of contemporary global trends towards achieving sustainable development and its disclosure and the orientations of economic institutions and units in different countries towards emphasizing the extent of commitment during practicing its a

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref