Glass- fiber-reinforced polymer (GFRP) offers a significant alternative to steel in reinforced concrete, with superior corrosion and fire resistance. Though less ductile and more brittle in stress–strain behavior than steel, it is very helpful to combine GFRP with steel reinforcement that improves the structural behavior. This research investigates the flexural characteristics of a one-way slab reinforced by a combination of GFRP and steel reinforcement. Three identical concrete slabs ((1500 × 550 × 120) mm and 43 MPa) were tested under static load with GFRP replacement ratios of (0, 20, and 40)%. The experimental data were utilized to verify a numerical model. The experimental outcomes indicated a substantial impact of the GFRP replacement ratio on the failure mode. The failure mode was flexural, flexural-shear, and shear regarding the reference slab, 20%, and 40% replacement, respectively. GFRP replacement influenced ductility and ultimate load by (9.13 and 10.7)% and (−21 and 5.0)% for replacement ratio (20 and 40)%, respectively. Based on the numerical analysis, the parametric study (considerably affected the structural response. Failure mode changed to flexural, and shear-flexural concerning (20 and 40)%, respectively. The optimum load was characterized at 40%, while max toughness and ductility were achieved at 20%.
To evaluate the bioactivity and the cytocompatibility of experimental Bioglass-reinforced polyethylene-based root-canal filling materials. The thermal properties of the experimental materials were also evaluated using differential scanning calorimetry, while their radiopacity was assessed using a grey-scale value (GSV) aluminium step wedge and a phosphor plate digital system. Bioglass 45S5 (BAG), polyethylene and Strontium oxide (SrO) were used to create tailored composite fibres. The filler distribution within the composites was assessed using SEM, while their bioactivity was evaluated through infrared spectroscopy (FTIR) after storage in simulated body fluid (SBF). The radiopacity of the composite fibres and their thermal properties were
... Show MoreThe laminar fluid flow of water through the annulus duct was investigated numerically by ANSYS fluent version 15.0 with height (2.5, 5, 7.5) cm and constant length (L=60cm). With constant heat flux applied to the outer duct. The heat flux at the range (500,1000,1500,2000) w/m2 and Reynolds number values were ≤ 2300. The problem was 2-D investigated. Results revealed that Nusselt number decrease and the wall temperature increase with the increase of heat flux. Also, the average Nusselt number increase as Re increases. And as the height of the annulus increase, the values of the temperature and the local and average Nusselt number increase.
A localized stenosis or aneurysm is a discontinuity that presents the pulse wave produced by the contracting heart with a reflection site. However, neither wave speed ( c) in these discontinuities nor the size of reflection in relation to the size of the discontinuity has been adequately studied before. Therefore, the aim of this work is to study the propagation of waves traversing flexible tubes in the presence of aneurysm and stenosis in vitro. We manufactured different sized four stenosis and four aneurysm silicone sections, connected one at a time to a flexible ‘mother’ tube, at the inlet of which a single semi-sinusoidal wave was generated. Pressure and velocity were measured simultaneously 25 cm downstream the inlet of th
... Show MoreThis study investigates the analytical approach of web reinforcement techniques, including high-strength concrete and laced reinforcement, to enrich improvement for the structural behavior of these beams. The analysis compares an unmodified cellular beam (LB1) with a web-reinforced beam (LB2), including the improvements in load-carrying capacity. The study considers the effects of reinforcement on critical design limit states, such as flexural strength, Vierendeel bending, web post-buckling, and shear resistance. The outcomes reveal significant enhancements in LB2’s structural behavior, with over a 100% increase in flexural strength and local axial force capacity and a 165% increase
Over the last few years, there has been a worldwide increase in the use of composite materials for rehabilitation of deficient reinforced concrete structures. One important application of this technology is the use of Carbon Fiber Reinforced Polymer (CFRP) jacket to provide external confinement of reinforced concrete columns. Square concrete column specimens 100×100×1000 mm with concrete
compressive strength of about 30 and 50 MPa, steel fiber volume fraction 0%, 0.5%, 0.75%, and percentage of longitudinal reinforcement 2.01%, 3.14% and 4.52% were tested until failure in previous research. In this research seven tested columns were repaired and rehabilitated using one layer of CFRP flexible wraps and tested to determine their ultim
Gurney flap (GF) is well-known as one of the most attractive plain flaps because of the simple configuration and effectiveness in improving the lift of the airfoil. Many studies were conducted, but the effects of GF on the various airfoil types need to be further investigated. This study aimed to clarify the effect of GF in the case of the supercritical airfoil RAE2822. This research includes a steady, two-dimensional computational investigation carried out on the supercritical airfoil type RAE-2822 to analyze Gurney flap (GF) effects on the aerodynamic characteristics of this type of airfoil utilizing the Spalart-Allmaras turbulence model within the commercial software Fluent. The airfoil with the Gurney flap was analyz
... Show More