This study aims to evaluate the melting characteristics of a phase change material (PCM) in a latent heat storage system equipped with hemispherical and quarter-spherical fins. A vertical triple-pipe heat exchanger is used as the PCM-based heat storage unit to improve the melting performance compared with a double-pipe system. Furthermore, the fins are arranged in inline and staggered configurations to improve heat transfer performance. For the quarter-spherical fins, both upward and downward directions are examined. The results of the system equipped with novel fins are compared with those without fins. Moreover, a fin is added to the heat exchanger’s base to compensate for the natural convection effect at the bottom of the heat exchanger. Considering similar fin volumes, the results show that the system equipped with four hemispherical fins on the side walls and an added fin on the bottom wall has the best performance compared with the other cases with hemispherical fins. The staggered arrangement of the fins results in a higher heat transfer rate. The downward quarter-spherical fins with a staggered configuration show the highest performance among all the studied cases. Compared with the case without fins, the heat storage rate improves by almost 78% (from 35.6 to 63.5 W), reducing the melting time by 45%.
In this work a study and calculation of the normal approach between two bodies, spherical and rough flat surface, had been conducted by the aid of image processing technique. Four kinds of metals of different work hardening index had been used as a surface specimens and by capturing images of resolution of 0.006565 mm/pixel a good estimate of the normal approach may be obtained the compression tests had been done in strength of material laboratory in mechanical engineering department, a Monsanto tensometer had been used to conduct the indentation tests.
A light section measuring equipment microscope BK 70x50 was used to calculate the surface parameters of the texture profile like standard deviation of asperity peak heights, centre lin
Fuzzy logic is used to solve the load flow and contingency analysis problems, so decreasing computing time and its the best selection instead of the traditional methods. The proposed method is very accurate with outstanding computation time, which made the fuzzy load flow (FLF) suitable for real time application for small- as well as large-scale power systems. In addition that, the FLF efficiently able to solve load flow problem of ill-conditioned power systems and contingency analysis. The FLF method using Gaussian membership function requires less number of iterations and less computing time than that required in the FLF method using triangular membership function. Using sparsity technique for the input Ybus sparse matrix data gi
... Show MoreThe audience is one of the important practical elements in the theatrical show and its importance is not confined to its static activity as a receiver element only, rather it went beyond that issue as an effective and influential element in the proceedings of the show and the process of meaning construction, that it gains an active role in the construction and production of the connotation that influences and is influenced by the actor, where the communication channels are open between the two sides, consequently a kind of watching and joint interaction happens between them. Thus, it has become necessary for the actor to create a suitable environment for the onlookers in order for it to be an essential part of the show system. The
... Show MoreThis work predicts the effect of thermal load distribution in polymer melt inside a mold and a die during injection and extrusion processes respectively on the structure properties of final product. Transient thermal and structure models of solidification process for polycarbonate polymer melt in a steel mold and die are studied in this research. Thermal solution obtained according to solidify the melt from 300 to 30Cand Biot number of 16 and 112 respectively for the mold and from 300 to 30 Cand Biot number of 16 for die. Thermal conductivity, and shear and Young Modulus of polycarbonate are temperature depending. Bonded contact between the polycarbonate and the steel surfaces is suggested to transfer the thermal load. The temperat
... Show MoreThe research aims to find out the impact of wages and benefits systems on the performance of employees, which included the research community on a sample of employees in the company, and the sample consisted of (50) employees and an employee, A questionnaire composed as prepared (23) paragraph, use the promised statistically methods in data collected by the questionnaire analysis. The research reached a number of results, the most prominent of which were: There is a correlation between wage systems, benefits and performance of employees, and the presence of the impact of the systems of wages and benefits to the performance of employees. The research was presented a set of recommendations including: increasing the effectiveness of
... Show MoreThis study aims to design unified electronic information system to manage students attendance in Lebanese French university/Erbil, as a system that simplifies the process of entering and counting the students absence, and generate absence reports to expel students who passed the acceptable limit of being absent, and by that we can replace the traditional way of using papers to count absence, with a complete electronically system for managing students attendance, in a way that makes the results accurate and unchangeable by the students.
In order to achieve the study's objectives, we designed an information syst
... Show MoreYY Lazim, NAB Azizan, 2nd International Conference on Innovation and Entrepreneurship, 2014
An experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air
... Show More