Preferred Language
Articles
/
1YYBtoYBIXToZYALMLKP
Improving the melting performance in a triple-pipe latent heat storage system using hemispherical and quarter-spherical fins with a staggered arrangement
...Show More Authors

This study aims to evaluate the melting characteristics of a phase change material (PCM) in a latent heat storage system equipped with hemispherical and quarter-spherical fins. A vertical triple-pipe heat exchanger is used as the PCM-based heat storage unit to improve the melting performance compared with a double-pipe system. Furthermore, the fins are arranged in inline and staggered configurations to improve heat transfer performance. For the quarter-spherical fins, both upward and downward directions are examined. The results of the system equipped with novel fins are compared with those without fins. Moreover, a fin is added to the heat exchanger’s base to compensate for the natural convection effect at the bottom of the heat exchanger. Considering similar fin volumes, the results show that the system equipped with four hemispherical fins on the side walls and an added fin on the bottom wall has the best performance compared with the other cases with hemispherical fins. The staggered arrangement of the fins results in a higher heat transfer rate. The downward quarter-spherical fins with a staggered configuration show the highest performance among all the studied cases. Compared with the case without fins, the heat storage rate improves by almost 78% (from 35.6 to 63.5 W), reducing the melting time by 45%.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 06 2020
Journal Name
Asian Journal Of Civil Engineering
Integrated project delivery (IPD) method with BIM to improve the project performance: a case study in the Republic of Iraq
...Show More Authors

View Publication
Scopus (18)
Crossref (20)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Ieee Xplore
A Hybrid Modified Lightweight Algorithm Combined of Two Cryptography Algorithms PRESENT and Salsa20 Using Chaotic System
...Show More Authors

Cryptography algorithms play a critical role in information technology against various attacks witnessed in the digital era. Many studies and algorithms are done to achieve security issues for information systems. The high complexity of computational operations characterizes the traditional cryptography algorithms. On the other hand, lightweight algorithms are the way to solve most of the security issues that encounter applying traditional cryptography in constrained devices. However, a symmetric cipher is widely applied for ensuring the security of data communication in constraint devices. In this study, we proposed a hybrid algorithm based on two cryptography algorithms PRESENT and Salsa20. Also, a 2D logistic map of a chaotic system is a

... Show More
Scopus (30)
Crossref (15)
Scopus Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of a Power System Transient Stability Using Static Synchronous Series Compensator SSSC
...Show More Authors

Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.

View Publication Preview PDF
Publication Date
Sat Feb 05 2011
Journal Name
International Journal Of Chemical Reactor Engineering
Mass Transport Properties of a Flow-Through Electrolytic Reactor Using Zinc Reduction System
...Show More Authors

An electrolytic process for the removal of Zn(II) from aqueous solution using a parallel amalgamated copper screens cathode operated in the flow through mode is proposed. The current-potential curves recorded at a rotating amalgamated copper disc electrode were used to determine diffusion coefficient of Zn(II). The performance of electrolytic reactor was investigated by using different flow rates at initial zinc ion concentration(48 mg/L). Taking into account the residential Zn(II) concentration, the best results were obtained for cathode potential of (-1.35 V vs. SCE) at flow rate (320 L/h). Zinc ion concentration was found to decrease from 48 mg/L to 1 mg/L during 120 min. of electrolysis. The experimental data are well correlate

... Show More
View Publication
Crossref
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
Real Time Quantum Bit Error Rate Performance Test for a Quantum Cryptography System Based on BB84 protocol
...Show More Authors

In this work, the performance of the receiver in a quantum cryptography system based on BB84 protocol is scaled by calculating the Quantum Bit Error Rate (QBER) of the receiver. To apply this performance test, an optical setup was arranged and a circuit was designed and implemented to calculate the QBER. This electronic circuit is used to calculate the number of counts per second generated by the avalanche photodiodes set in the receiver. The calculated counts per second are used to calculate the QBER for the receiver that gives an indication for the performance of the receiver. Minimum QBER, 6%, was obtained with avalanche photodiode excess voltage equals to 2V and laser diode power of 3.16 nW at avalanche photodiode temperature of -10

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 20 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of the external audit in improving the performance of the services provided: Applied research in the municipal directorate in ALMuthanna
...Show More Authors

The subject of improving the performance of services provided by government institutions of the important topics at the present time because of their direct contact at the service of citizens and the increased importance of these units as a result of the diversity of activities performed by the so governments of the countries and their people made sure to pay attention to the good use of those allocated to those sectors of resources and spending in the service prescribed and manage the highest level of efficiency and effectiveness and monitor the proper management of the money used in those sectors and evaluate their performance through the Supreme Audit Institutions so that they can play their role oversight and contribute to th

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
A theoretical Design of a cover for lowering the solar cells temperature and enhance their performance
...Show More Authors

In this research, main types of optical coatings are presented which are used as covers for solar cells, these coatings are reflect the infrared (heat) from the solar cell to increase the efficiency of the cell (because the cell’s efficiency is inversely proportional to the heat), then the theoretical and mathematical description of these optical coatings are presented, and an optical design is designed to meet this objective, its optical transmittance was calculated using (MATLAB R2008a) and (Open Filters 1.0.2) programs

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Robust Queues Models and its Role in Improving Performance in the City of Medicine / Baghdad Teaching Hospital / Clinic Internal Medicine Advisory
...Show More Authors

The purpose of this research is to a treatment the impact of Views outliers to the estimators of a distributed arrival and service to the theory of queues and estimate the distribution parameters depending on the robust estimators, and when he was outliers greatest impact in the process of estimating the both distributions mentioned parameters, it was necessary to use way to test that does these data contain abnormal values ​​or not? it was used the method ( Tukey ) for this purpose and is of the most popular ways to discover the outliers , it shows that there are views abnormal (outliers ) in the estimators of each of the distributional arrival and service, which have a significant impact on the calculation of these estimato

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Design and evalution of a solar PV system
...Show More Authors

PV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building   220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien

... Show More
View Publication Preview PDF
Crossref