Preferred Language
Articles
/
1ReRYo8BVTCNdQwCjHSB
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. When increasing the field size, the percentage of surface dose increases that this could be caused by an increase of the amount of scattering in the larger fields. Conclusion: There is almost no difference in depth dose between homogenous planning and water phantom

Publication Date
Thu Apr 01 2021
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Pushing towards ehealth for iraqi hypertensives: an integrated class association rules into SECI model
...Show More Authors

<span lang="EN-GB">This paper highlights the barriers that have led to a delay in the implementation of E-Health services in Iraq. A new framework is proposed to improve the E-Health sector using a SECI model which describes how explicit and tacit knowledge is generated, transferred, and recreated in organizations through main stages (socialization, externalization, combination and internalization). Class association rules (CARs) is integrated to mine the SECI model by extracting related rules which correspond to the medical advice. The proposed framework (SECICAR) can be done through a web portal to assemble healthcare professionals, patients in one environment. SECICAR will be applied to the hypertension community to show th

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sat Mar 01 2025
Journal Name
Acta Marisiensis - Seria Medica
Transcatheter balloon valvuloplasty for children with severe pulmonary valve stenosis: A single-center experience
...Show More Authors
Abstract<p> <bold>Objectives</bold>: this study aim to assess the effectiveness of the Transcatheter balloon valvoplasty (BVP) of severe Pulmonary stenosis (PS) and identify possible complications and predictors for the outcome.</p><p> <bold>Methods</bold>: A retrospective study was conducted at the Iraqi Center of Cardiac Diseases for a 2-year duration in the period from 2021 to the end of 2023; the patients with confirmed severe PS of both genders within the age equal to or less than 18 years were included. For every patient included in the present study, the following data were collected: Demographic data, Echoc</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sat Sep 21 2013
Journal Name
Nonlinear Dynamics
BER performance enhancement for secure wireless optical communication systems based on chaotic MIMO techniques
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Apr 06 2017
Journal Name
Chalcogenide Letters
CdS/PMMA-based inorganic/organic heterojunction for H<sub>2</sub>S gas sensing
...Show More Authors

The performance of H2S sensor based on poly methyl methacrylate (PMMA)-CdS nanocomposite fabricated by spray pyrolysis technique has been reported. XRD pattern diffraction peaks of nano CdS has been indexed to the hexagonally wurtzite structured The nanocomposite exhibits semiconducting behavior with optical energy gap of4.06eV.SEM morphology appears almost tubes like with CdS/PMMA network. That means the addition of CdS to polymer increases the roughness in the film and provides high surface to volume ratio, which helps gas molecule to adsorb on these tubes. The resistance of PMMA-CdS nanocomposite showed a considerable change when exposed to H2S gas. Fast response time to detect H2S gas was achieved by using PMMA-CdS thin film sensor. The

... Show More
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
Sellar hematoma as a new potential radiological clue for superior hypophyseal artery aneurysm rupture
...Show More Authors

Background. In cases of spontaneous subarachnoid haemorrhage (SAH) with multiple intracranial aneurysms (MIAs) detected on angiography, some radiological clues assist in determining the site of a ruptured aneurysm which is bleeding is quite beneficial for the selection of the best treatment strategy. Case description. We report a case of a 60 years old patient who presented with spontaneous SAH, sellar hematoma, and three different aneurysms detected in angiography. Although the right Posterior communicating artery (PcomA) aneurysms showed Murphy’s teat on angiography intraoperatively, we discovered that the right superior hypophyseal aneurysm (SHA) was the source of the index bleeding. Both aneurysms were clipped successfully. Co

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ssrn Electronic Journal
Highly Sensitive Fiber Brag Grating Based Gas Sensor Integrating Polyaniline Nanofiber for Remote Monitoring
...Show More Authors

View Publication
Crossref
Publication Date
Wed Aug 19 2020
Journal Name
Applied Water Science
Spiral path three phase fluidized bed reactor for treating wastewater contaminated with engine oil
...Show More Authors
Abstract<p>In this study, a new type of circulating three-phase fluidized bed reactor was conducted by adding a spiral path and was named as spiral three-phase fluidized bed reactor (TPFB-S) to investigate the possibility for removing engine oil (virgin and waste form) from synthetic wastewater by using Ricinus communis (RC) leaves natural and activated by KOH. The biosorption process was conducted by changing particle diameter in the range 150–300 and 300–600 µm, liquid flow rate in the range 2.5–4.5 L/min and gas flow rate in range of 0–1 L/min, while other parameters initial oil emulsion concentration, pH, adsorbent concentration, agitation speed and contact time were kept constant at 2000 mg/L, 2,</p> ... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
A Hybrid Coefficient Decimation- Interpolation Based Reconfigurable Low Complexity Filter Bank for Cognitive Radio
...Show More Authors

Non uniform channelization is a crucial task in cognitive radio receivers for obtaining separate channels from the digitized wideband input signal at different intervals of time. The two main requirements in the channelizer are reconfigurability and low complexity. In this paper, a reconfigurable architecture based on a combination of Improved Coefficient Decimation Method (ICDM) and Coefficient Interpolation Method (CIM) is proposed. The proposed Hybrid Coefficient Decimation-Interpolation Method (HCDIM) based filter bank (FB) is able to realize the same number of channels realized using (ICDM) but with a maximum decimation factor divided by the interpolation factor (L), which leads to less deterioration in stop band at

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 08 2024
Journal Name
Applied System Innovation
Adaptive Active Disturbance Rejection Control for Vehicle Steer-by-Wire under Communication Time Delays
...Show More Authors

In this paper, an adaptive active disturbance rejection control is newly designed for precise angular steering position tracking of the uncertain and nonlinear SBW system with time delay communications. The proposed adaptive active disturbance rejection control comprises the following two elements: (1) An adaptive extended state observer and (2) an adaptive state error feedback controller. The adaptive extended state observer with adaptive gains is employed for estimating the unmeasured velocity, acceleration, and compound disturbance which consists of system parameter uncertainties, nonlinearities, exterior disturbances, and time delay in which the observer gains are dynamically adjusted based on the estimation error to enhance est

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
‘Peacock tail’ Clipping Technique for a Giant Middle Cerebral Artery Aneurysm: A Technical Note
...Show More Authors

Background: Giant middle cerebral artery (MCA) aneurysms are surgically challenging lesions. Because of the complexity and variability of these aneurysms, a customized surgical technique is often needed for each case. In this article, we present a modified clip reconstruction technique of a ruptured complex giant partially thrombosed middle cerebral artery aneurysm.

Case description: The aneurysm was exposed using the pterional approach. Following proximal control, the aneurysm sac was decompressed. Then, we applied permanent clips to reconstruct the aneurysm neck. The configuration of the aneurysm mandated a tailored clipping pattern to account for resi

... Show More
View Publication Preview PDF
Scopus Crossref