Preferred Language
Articles
/
1OY7fZwBmraWrQ4dIEr5
Development of natural deep eutectic solvent‐assisted liquid–liquid extraction method for soap removal from biodiesel: Optimization and kinetics
...Show More Authors
Abstract<p>The soap content in biodiesel is an important challenge during the production and purification processing of biodiesel. Natural deep eutectic solvents (NADES) have recently attracted considerable interest as an environmentally suitable substitute for traditional solvents in the biodiesel industry. This work investigates the soap removal from the contaminated biodiesel using NADES. Eight choline chloride‐based deep eutectic solvents (DESs) were screened using the conductor‐like screening model for real solvents (COSMO‐RS) to identify the most suitable solvent for soap removal and were validated experimentally. The effect of NADES molar ratio, NADES:biodiesel ratio, mixing speed and extraction time on the extraction efficiency were investigated. COSMO‐RS screening revealed that the malonic acid‐based NADES possess higher soap elimination, and this is compatible with the experimental screening. The higher extraction efficiency of 99.18% was achieved under the optimum conditions of 1:3 of NADES molar ratio, 1:1 DES:biodiesel, 150 rpm and 15 min of extraction time. The soap removal followed the first‐order kinetic equation with a rate constant of 0.183 min<sup>−1</sup>. This technique offers innovative and environmentally friendly routes for downstream processing of contaminated biodiesel.</p>
Scopus Crossref
View Publication
Publication Date
Thu Sep 08 2022
Journal Name
Al-khwarizmi Engineering Journal
Kinetics of Electrochemical Removal of Nickel using Bio-electrochemical Reactor with Packed Bed Rotating Cylinder Cathode
...Show More Authors

The kinetics of nickel removal from aqueous solutions using a bio-electrochemical reactor with a packed bed rotating cylinder cathode was investigated. The effects of applied voltage, initial nickel concentration, the rotation speed of the cathode, and pH on the reaction rate constant (k) were studied. The results showed that the cathodic deposition occurred under mass transfer control for all values of the applied voltage used in this research. Accordingly, the relationship between concentration and time can be represented by a first-order equation. The rate constant was found to be dependent on the applied voltage, initial nickel concentration, pH, and rotation speed. It was increased as the applied voltage increased and decreased as t

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Isotherms and Kinetics Study for Adsorption of Nitrogen from Air using Zeolite Li-LSX to Produce Medical Oxygen
...Show More Authors

This research investigates the adsorption isotherm and adsorption kinetics of nitrogen from air using packed bed of Li-LSX zeolite to get medical oxygen. Experiments were carried out to estimate the produced oxygen purity under different operating conditions: input pressure of 0.5 – 2.5 bar, feed flow rate of air of 2 – 10 L.min-1 and packing height of 9-16 cm. The adsorption isotherm was studied at the best conditions of input pressure of 2.5 bar, the height of packing 16 cm, and flow rate 6 Lmin-1 at ambient temperature, at these conditions   the highest purity of oxygen by this system 73.15 vol % of outlet gas was produced. Langmuir isotherm was the best models representing the experimental data., and the m

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Optimization of Hole Cleaning and Cuttings Removal in High Inclined Till Horizontal Well
...Show More Authors

The goal of this experimental study is to determine the effects of different parameters (Flow rate, cuttings density, cuttings size, and hole inclination degree) on hole cleaning efficiency. Freshwater was used as a drilling fluid in this experiment. The experiments were conducted by using flow loop consist of approximately 14 m (46 ft) long with transparent glass test section of 3m (9.84 ft.) long with 4 inches (101.6 mm) ID, the inner metal drill pipe with 2 inches (50.8 mm) OD settled with eccentric position positive 0.5. The results obtained from this study show that the hole cleanings efficiency become better with high flow rate (21 m3/hr) and it increase as the hole inclination angles increased from 60 to 90 degree due to dominated

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Extraction and Purification of albumin from Hunan plasma
...Show More Authors

This study includes adescription of Human serum Albumin by amodified using ion- exchange chromatography with manipulated comparison with cold ethanol precipitation method , It has been nticed that this procedure is superior orer the classical method . The Final yield by the new method 69.32% with purity of 83.42% compared with cohn which yield 60.30 % with purity of 80.7 % . The new method prored that it suitable for the pusi Fication of such material because it yield no precipitation material and it increases the Final yield of albumin solutions . • Human serum Albumin . • Albumin purification . • Ion – exchange chromatography . • Human plasma . • Albumin extraction .

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Waste Water Treatment by Liquid-Solid Adsorption Using Calcined Sand-Clay Mixture Adsorbent
...Show More Authors

Effluent from incompetent wastewater treatment plants (WWTPs) contains a great variety of pollutants so support water treatments are essential. The present work studies the removal of phosphate species from aqueous solutions by adsorption on to spherical Calcined Sand -Clay mixture (CSCM) used a natural, local and low-cost adsorbent. Batch experiments were performed to estimate removal efficiency of phosphate. The adsorption experiments were carried out as function of pH, dose of adsorbent, initial concentration, temperature and time of adsorption. The efficient removal was accomplished for pH between 10 and 12. The experimental results also showed that the removal of phosphate by (CSCM) was rapid (the % removal 98.9%, 92%, 90%, 89% in 6

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun May 15 2022
Journal Name
Revistabionatura
Synthesis and characterization of azo liquid crystal compounds based on 5H-Thiazolo [3,4-b][1,3,4] thiadiazole unit
...Show More Authors

A calamitic symmetric liquid crystalline consisting of an azo group containing 5H-Thiazolo[3,4-b][1,3,4]thiadiazole moiety compound[III] was synthesized via sequence reactions starting from reaction terephthaldehyde with mercaptoacetic acid and thiosemicarbazide in the presence of concentrated sulfuric acid to synthesized 5,5'-(1,4-phenylene)bis(5Hthiazolo[4,3-b][1,3,4]thiadiazol-2-amine)[I] then the azo compound [II] synthesized by coupling between diazonium salt of the compound [I] with phenol at (0-4) ̊C., after that the compound [III] was synthesized by the reaction of the compound [II] with methyl bromide in alkaline media. The compounds are characterized by melting points, FTIR and 1HNMR spectroscopy. The mesomorphic behavior was stu

... Show More
Preview PDF
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Detection of Epicatechin in Camellia sinensis Leaves by Thin Layer Chromatography and High Performance Liquid Chromatography Techniques
...Show More Authors

    The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are  absolute ethanol, 50% aqueous ethanol and water  for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (93)
Crossref (83)
Scopus Clarivate Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Cadmium Removal Using Bio-Electrochemical Reactor with Packed Bed Rotating Cylindrical Cathode: A Kinetics Study
...Show More Authors

   The kinetics of removing cadmium from aqueous solutions was studied using a bio-electrochemical reactor with a packed bed rotating cylindrical cathode. The effect of applied voltage, initial concentration of cadmium, cathode rotation speed, and pH on the reaction rate constant (k) was studied. The results showed that the cathodic deposition occurred under the control of mass transfer for all applied voltage values ​​used in this research. Accordingly, the relationship between logarithmic concentration gradient with time can be represented by a first-order kinetic rate equation. It was found that the rate constant (k) depends on the applied voltage, the initial cadmium concentration, the pH and the rotational speed of cathode. It

... Show More
View Publication Preview PDF
Crossref (2)
Crossref