Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.
Using zooplankton as bioindicators, this study evaluates the ecological condition of the Euphrates River in Iraq's Babylon Province. Site 1 (North Hillah, next to the old Babylon ruins), Site 2 (Hillah city center), Site 3 (South Hillah, close to Al-Mahaweel), and Site 4 (near Al-Kifl town) were the four monitoring locations chosen along the river. The highest and lowest averages of the measured physical and chemical factors indicate temperature (25.1°-29.4°), pH (7.2-7.9), electrical conductivity (EC) (940 µS/cm-1241µS/cm), total dissolved solids TDS (591 mg/L-789mg/L), dissolved oxygen (DO) (5.6 mg/ l-7.1 mg/L), biological oxygen demand (BOD5) (2.4mg/L-4.2 mg/L), nitrate (1.3 mg/L–3.2 mg/L), nitrite (0.04 mg/L–0.13 mg/L),
... Show MoreBackground: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa
... Show MoreThe Ground Penetrating Radar (GPR) is frequently used in pavement engineering
for road pavement inspection. The main objective of this work is to validate
nondestructive, quick and powerful measurements using GPR for assessment of subgrade
and asphalt /concrete conditions. In the present study, two different antennas
(250, 500 MHz) were used. The case studies are presented was carried in University
of Baghdad over about 100m of paved road. After data acquisition and radar grams
collection, they have been processed using RadExplorer V1.4 software
implementing different filters with the most effective ones (time zero adjustment and
DC removal) in addition to other interpretation tool parameters.
The interpretatio
Efficacy of Several Forms of Storage Medium on Avulsed Teeth's Enamel Surface Roughness (An in Vitro Study), Rawaa Sadiq Obeid1*, Muna Saleem Khalaf2
Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and
... Show MoreMunicipal solid waste generation in Babylon Governorate is often affected by changes in lifestyles, population growth, social and cultural habits and improved economic conditions. This effect will make it difficult to plan and draw up future plans for solid waste management.In this study, municipal solid waste was divided into residential and commercial solid wastes. Residential solid wastes were represented by household wastes, while commercial solid wastes included commercial, institutional and municipal services wastes.For residential solid wastes, the relational stratified random sampling was implemented, that is the total population should be divided into clusters (socio-income level), a random sample was taken in e
... Show MoreVol. 6, Issue 1 (2025)
A large amount of thermal energy is generated from burning hazardous chemical wastes, and the temperature of the flue gases in hazardous waste incinerators reaches up to (1200 °C). The flue gases are cooled to (40°C) and are treated before emission. This thermal energy can be utilized to produce electrical power by designing a system suitable for dangerous flue gases in the future depending on the results of much research about using a proto-type small steam power plant that uses safe fuel to study and develop the electricity generation process with water tube boiler which is manufactured experimentally with theoretical development for some of its parts which are inefficient in experimental work. The studied system gen
... Show MoreAround fifty isolates of Salmonella enterica serovar Typhi were isolated from blood specimens of patients referring to several hospitals in Kirkuk province, Iraq. The results revealed that all isolates developed resistance to trimethoprim-sulfamethoxazole and chloramphenicol. However, neither sul2 nor tem genes were detected. Moreover, only ten isolates were positive for catP. Our data suggested participation of other genes or mechanisms allow these multidrug isolates to resist the antibiotics in question.
Irrigation has significant role in endodontic treatment, many types of antimicrobial irrigation solutions have been used, but due to the ineffectiveness, safety concerns and side effects of this irrigation, the herbal alternatives for endodontic irrigants might be beneficial. Objectives This study compared the in vitro effectiveness of tea tree oil and clove oil as possible irrigants in endodontics against Enterococcus faecalis in comparison with 3% Sodium hypochlorite. Materials and Methods E. faecalis was isolated from patients in need for endodontic treatment; VITEK was employed for E. faecalis isolate conformation. Muller Hinton agar was prepared with 100μl of freshly prepared suspension of E.faecalis. Wells of 6mm diameter and 4mm dep
... Show More