Preferred Language
Articles
/
1BjhfpUBVTCNdQwC8i4b
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.

Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 22 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Assessment of Causality, Severity and Seriousness of Adverse Event Following Immunization in Iraq: A Retrospective Study Based on Iraqi
...Show More Authors

Immunization is one of the most cost-effective and successful public health applications. The results of immunization are difficult to see as the incidence of disease occurrence is low while adverse effects following the immunization are noticeable, particularly if the vaccine was given to apparently healthy person. High safety expectations of population regarding the vaccines so they are more prone to hesitancy regarding presence of even small risk of adverse events which may lead to loss of pub

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Computation of The Efficiency ofHarmonic Generation Using Cascading Configuration.
...Show More Authors

In the present work theoretical relations are derived for the efficiency evaluation for the generation of the third and the fourth harmonics u$ing crystal cascading configuration. These relations can be applied to a wide class of nonlinear optical materials. Calculations are made for beta barium borate (BBO) crystal with ruby laser /.=694.3 nm . The case study involves producing the third harmonics at X. =231.4 nm of the fundamental beam. The formula of efficiency involves many parameters, which can be changed to enhance the efficiency. The results showed that the behavior of the efficiency is not linear with the crystal length. It is found that the efficiency increases when the input power increases. 'I'he walk-off length is calculated for

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Transylvanian Review
Metacongnitive Thinking Skills Implied in Questions and Activities of Computer Textbook for the Fifth Grade Preparatory
...Show More Authors

The research aims to know the availability of supra-cognitive thinking skills in the questions and activities of the computer book for the fifth grade preparatory scientific and literary branches in Iraq for the academic year 2018/2019, as the researcher has prepared a list of supra-cognitive thinking skills included two areas and (6) key skills and (27) A sub - skill, where by the questions and activities of the aforementioned authors were analyzed. The researcher followed the descriptive analytical approach "method of content analysis", and adopted the explicit and implicit unit of analysis, as was verified the validity and stability of the analysis, and the results showed unevenness and imbalance in the distribution of supra-cognitive th

... Show More
Preview PDF
Publication Date
Tue Oct 20 2020
Journal Name
Journal Of Research In Medical And Dental Science
The Effect of Chicken Eggshell Extract on Microhardness of Artificially Induced Dental Erosion in Permanent Teeth (In Vitro Study)
...Show More Authors

The Effect of Chicken Eggshell Extract on Microhardness of Artificially Induced Dental Erosion in Permanent Teeth (In Vitro Study), Shatha A Abbas*, Alhan A Qasim

View Publication Preview PDF
Publication Date
Sun Mar 15 2026
Journal Name
Alustath Journal For Human And Social Sciences
Translation Assessment of the Conditional Sentences in “The Dream of a Ridiculous Man” Story by Dostoevsky
...Show More Authors

Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Studying the Effect of Different Separating Medium on the Roughness of the tissue surface of Acrylic Denture Base (In Vitro Study)
...Show More Authors

Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Heliyon
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was tr

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Mon Oct 05 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Accuracy of spiral computed tomography in evaluation of maxillary sinus septa among dentate and edentulous Iraqi subjects (Comparative study)
...Show More Authors

Background: Presence of maxillary sinus septa has been known to be a complicating factor for sinus elevation procedure and implant placement in posterior maxilla. The maxillary sinuses septa are thin walls of cortical bone inside the sinus. They vary in number, location, and height. This study aimed to discover the accuracy of Spiral Computed Tomographic Scan in evaluation the maxillary sinus septa (prevalence, location, height) in subjects with dentate, partially edentulous and completely edentulous maxilla. Material and method: This study included (267) subjects ranged from (20-70 years), (132) male and (135) female divided into three groups, (97) fully dentate group, (102) partially edentulous group and (68) completely edentulous group w

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Biomechanics
In vitro wear testing of a contemporary design of reverse shoulder prosthesis
...Show More Authors

Reverse shoulder arthroplasty is an increasingly common surgical intervention. However there are concerns and known limitations in relation to such joint replacement, while novel designs of reverse shoulder prostheses continue to appear on the market. Many claim to offer improvements over older designs but such assertions are difficult to validate when there is no consensus as to how such implants should be tested in vitro or even if such testing is necessary. In order to permit appropriate in vitro testing of reverse shoulder prostheses a unique, multi-station test rig was designed which was capable of applying motion in three axes to test prostheses. The shoulder simulator can apply up to 110° of motion in the flexion–extension and abd

... Show More
View Publication
Scopus (30)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Sun May 15 2022
Journal Name
Al-kindy College Medical Journal
Assessment of Nurses’ Knowledge, Attitude, and Practices on Antibiotic Use and Resistance in Baghdad: A single-hospital study
...Show More Authors

Background: There are so many evidences that there was antimicrobial resistance, and there were many strains that emerged which were difficult to treat. We are living in a situation that the dissemination of multiple drug resistant bacteria can lead us to the situation, in which no treatment could be offered for bacterial infection in future.

Aim of study: Assessment of nurses’ knowledge, attitude, and practices on antibiotic use and resistance in Fatima Al Zahra hospital in Baghdad.

Subjects and Methods:  A cross-sectional study. The study was carried on from 1st of February to 31st of March 2021.  A questionnaire was constructed by the research team based on literature review and was adapted to asses

... Show More
View Publication Preview PDF
Crossref (3)
Crossref