Chemical pesticides have an impact on other living organisms in addition to their intended target organisms. Any chemical pesticide is therefore made safe for use by examining its biological characteristics and side effects. The present study was aimed at determining the resistance efficiency of six bacterial isolates obtained from malathion-contaminated soils. Bacteria were isolated from soil samples collected in Adhamiya, Baghdad, Iraq. Biochemical tests and VITEK 2 compact equipment were used to identify the bacterial isolates. Primary and secondary screening tests were conducted on the bacterial isolates for resistance against malathion pesticides. The optimal bacterial growth conditions were determined in malathion-contaminated media.
... Show MoreEleven yoghurt samples were collected from local markets in Baghdad to isolate Lactobacillus buchneri. Only 3 isolates of L. buchneri were found and the isolate No. 3 was the most producer of bacteriocin. Bacteriocin was adsorbed 100% onto silicic acid at pH 6.0-7.0. Below or above these pH values, adsorption was decreased, ranging between 35 and 90%. Therefore, pH 6.0 was used for the purification procedure. The purification procedure including silicic acid adsorption/desorption and cation-exchange chromatography (CEC) resulted in a 11.11 fold increase in the final specific activity of pure bacteriocin (1176.47 Au/mg) compared to the culture supernatant which was 32.64 Au/mg. The molecular weight was determined to be about 3.4 kDa. The bac
... Show MoreBackground: Anemia is a common finding in patients with renal failure disease and it is, primarily, due to reduced production of iron and erythropoietin. Therefore, the aim of current study was to evaluate the relationship between serum level of hepcidin 25, on the one hand, and levels of serum iron, total iron-binding capacity, serum erythropoietin and transferrin saturation% in Iraqi male patients undrgoning haemodialysis.. Methods: Serum from75 males in the end stage of hemodialysis, as group one, and 25 Iraqi healthy malecontrols, as group two, were recruited in this study. Results: Data from current study showed significant increase in hepcidin 25 and significant decrease in serum iron, total iron-binding capacity, transferrin saturati
... Show MoreThis study investigates the factors that led to the outbreak of protest movements in Sudan, since Sudan’s independence in 1956 until December 2018. The study aims to identify the role of protests in bringing about political and social transformations in Sudan, besides identifying the factors that help in the success or failure of the governments that resulted from those protests, with special emphasis on the challenges of the government of the 2018 revolution. The main results of the study reveal that the December 2018 protests are the largest in term of numbers, and witness huge participation of youth and women, and the slogans raised were national and comprehensive. However, the challenges that the transitional government is going th
... Show MoreNew membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreUltrasonic Extraction method followed by gradient HPLC was carried out for the simultaneous determination of four insecticides are [imidacloprid (Imi), thiamethoxam (Thi), indoxacarb (Ind) and abamectin (Aba)] used to combat the major insect pests in Iraq, whitefly, Dubas Bug, worms fruits as well as to combat the spiders – dream respectively in eco-soil samples. The extraction recovery was in the range of 99.77 to 109.1 %. The dissipation kinetics and residual levels of these insecticides in soil sample was studied under field ecosystem. The half-life of the mix insecticides was determined. The half-life was in range of 0.38 to 4.06 days with the soil samples were brought from the Agricultural Land called Nahrawan located in th
... Show More