Preferred Language
Articles
/
1BZgZ4cBVTCNdQwCH0n5
Simultaneous determination of time-dependent coefficients and heat source
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Thu Jul 01 2021
Journal Name
Applied Thermal Engineering
Consecutive charging and discharging of a PCM-based plate heat exchanger with zigzag configuration
...Show More Authors

View Publication
Scopus (76)
Crossref (70)
Scopus Clarivate Crossref
Publication Date
Thu May 28 2026
Journal Name
Iraqi Journal Of Science
UNSTEADY PRESSURE DROP AND HEAT TRANSFER OFMAGNETOHYDRODYNAMIC ANNULAR TWO-PHASE INRECTANGULAR CHANNEL
...Show More Authors

An annular two-phase, steady and unsteady, flow model in which a conductingfluid flow under the action of magnetic field is concavely. Two models arepresented, in the model one; the magnetic field is perpendicular to the long side ofthe channel, while in the model two is perpendicular to the short side. Also, westudy, to some extent the single-phase liquid flow.It is found that the motion and heat transfer equations are controlled by differentdimensionless parameters namely, Reynolds, Hartmann, Prandtl, and Poiseuilleparameters. The Laplace transform technique is used to solve each of the motion andheat transfer equations. The effects of each of dimensionless parameters upon thevelocity and heat transfer is analyzed.A comprehensive study fo

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Heat Transfer and Hydrodynamic in Internal Jacket Airlift Bioreactor with Microbubble Technology
...Show More Authors

   Integration of laminar bubbling flow with heat transfer equations in a novel internal jacket airlift bioreactor using microbubbles technology was examined in the present study. The investigation was accomplished via Multiphysics modelling to calculate the gas holdup, velocity of liquid recirculation, mixing time and volume dead zone for hydrodynamic aspect. The temperature and internal energy were determined for heat transfer aspect.

   The results showed that the concentration of microbubbles in the unsparged area is greater than the chance of large bubbles with no dead zones being observed in the proposed design.  In addition the pressure, due to the recirculation velocity of liquid around the draft

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Thermal Efficiency for Passive Solar Chimney with and Without Heat Storage material
...Show More Authors

In this study, a different design of passive air Solar Chimney(SC)was tested by installing it in the south wall of insulated test room in Baghdad city. The SC was designed from vertical and inclined parts connected serially together, the vertical SC (first part) has a single pass and Thermal Energy Storage Box Collector (TESB (refined paraffin wax as Phase Change Material(PCM)-Copper Foam Matrix(CFM))), while the inclined SC was designed in single pass, double passes and double pass with TESB (semi refined paraffin wax with copper foam matrix) with selective working angle ((30o, 45o and 60o). A computational model was employed and solved by Finite Volume Method (FVM) to simulate the air i

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Computers, Materials & Continua
An Efficient Method for Heat Recovery Process and燭emperature燨ptimization
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Nov 04 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Quality of Life for Adult Patients
...Show More Authors

Objective: The study aimed to determine quality of life domains for adult patients with limbs loss and to identify
the association between quality of life domains and demographic characteristics and medical information.
Methodology: A descriptive study was carried out at Baghdad artificial limb center, Al-Salam medical
rehabilitation center, Al-Ghadeer medical rehabilitation center and the rheumatoid and medical rehabilitation
center for the period from September 2007 to April 2008. A purposive ''non- probability'' sample of (200)
patients with limbs loss. Questionnaire form was constructed for the purpose of the study. Data were collected
through the application of the questionnaire and interview technique. Data were a

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Development of a Simple Colorimetric Determination of Dexamethasone
...Show More Authors

A simple, environmentally benign, cost-effective, and sensitive colorimetric determination for the pharmaceutical drug dexamethasone sodium phosphate (DXP) has been developed by the formation of a colored complex with fluoranil. The process was sensitive and linear over the range 1 to 40 μg/mL, excellent correlation coefficient 0.9989, recovery% 99.80 ± 1.3, limit of detection (LOD) and limit of quantification (LOQ) were 0.23 and 0.9 μg/mL, respectively, and good RSD ~1.63%. The experimental conditions were optimized after an intensive study. The approach was validated statistically for the quantification of the analyte in its pure and/or pharmaceutical form. Despite the proposed approach is selective, it still can be applied for

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Predicting of Temperature Distribution in Direct Contact Heat Transfer
...Show More Authors

An experimental and theoretical investigation of three phase direct contact heat transfer by evaporation of refrigerant drops in an immiscible liquid has been carried out. Refrigerant Rl2 and R134a were used for the dispersed phase, while water and brine were the immiscible continuous phase. A numerical analysis is presented to predict the temperature distribution throughout the circular test column radially and axially is achieved. Experimental measurements of the temperature distribution have been compared with the numerical results and are discussed .A comparison between the experimental and theoretical results showed acceptable agreement and applicability of the derived equations. Comparison with other related work showed similar beh

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 20 2019
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Heat Exchanger Performance by Using Dimpled Tube
...Show More Authors

The enhancement of heat exchanger performance was investigated using dimpled tubes tested at different Reynolds numbers, in the present work four types of dimpled tubes with a specified configuration manufactured, tested and then compared performance with the smooth tube and other passive techniques performance. Two dimpled arrangements along the tube were investigated, these are inline and staggered at constant pitch ratio X/d=4, the test results showed that Nusselts number (heat transfer) of the staggered array is higher than the inline array by 13%.  The effect of different depths of the dimple (14.5 mm and 18.5 mm) has been also investigated; a tube with large dimple diameter enhanced the Nusselts number by about 25% for the ran

... Show More
View Publication Preview PDF
Crossref (3)
Crossref