Preferred Language
Articles
/
1BYECIwBVTCNdQwCSvY5
Study of Plasma Metanephrine Level As Biochemical Parameter in Pregnant Women with Preeclampsia
...Show More Authors

Pregnancy- including hypertension(PIH), also known as preeclampsia, is one of the major causes of maternal and fetal death. This study was carried out on 30 pregnant women with preeclampsia and 30 healthy pregnant women as control ranging in age mean ±SD (28.84±3.55) years , BMI (76.80±9.78) Kg/m2 and gestation age(30.82±0.75)week. The aim of this research was studied the plasma Metanephrine level and other biochemical parameters such as Hemoglobin(Hb), serum Protein, S. Albumin, Globulin, Albumin/Globulin ratio (Alb/Glu. ratio), S.Glutamate Pyruvate aminotransferase (GPT), S.Glutamate Oxaloacetate aminotransferase(GOT). The obtained results have been compared with 30 healthy pregnant women as control group. The result showed that there was significant increase in mean value of Hb in group A(pregnant women with preeclampsia) when compared to group B(healthy pregnant women). The present study showed no significant changes was observed in the level of S. Protein, globulin, Alb./Glu. ratio, GPT and GOT as compared to control group. While Albumin showed a significant decrease in group A(pregnant women with preeclampsia) when compared with group B(healthy pregnant women) and significant increase in the levels of metanephrine, metanephrine/protein ratio, metanephrine/Alb ratio in group A (pregnant women with preeclampsia) to group B(healthy pregnant women).The present study conclude that the increase in the levels of metanephrine, metanephrine/protein ratio, metanephrine/Alb ratio in pregnant women with preeclampsia may be used as a marker to evaluate the development of disease. The current study recommend to take more case and measurement metanephrine in plasma and urine. K

Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EVALUATION OF SPORTS AWARENESS AMONG WOMEN AT THE UNIVERSITY OF BAGHDAD FOR THE PERIOD 2011-2016 AND STUDY THE FACTORS AFFECTING THEIR PARTICIPATION IN SPORTS ACTIVITIES: EVALUATION OF SPORTS AWARENESS AMONG WOMEN AT THE UNIVERSITY OF BAGHDAD FOR THE PERIOD 2011-2016 AND STUDY THE FACTORS AFFECTING THEIR PARTICIPATION IN SPORTS ACTIVITIES
...Show More Authors

The exercise of activities and sports are of great importance to public health and to maintain the ideal health weight as well as the psychological and mental comfort of humans. The aim of this study is to determine the contribution and participation of educated females in physical activities at the University of Baghdad hall for the years 2011-2016, and to show the factors that influence women's contribution to physical activities at the university by selecting 100 students of males and 100 females' students randomly. During the questioning questions and statistical analysis of the questioning to find out the reasons for the discouraging contribution of the women to the various physical activities and try to find solutions and r

... Show More
View Publication Preview PDF
Publication Date
Wed May 08 2024
Journal Name
Babylon: Abjad Publising House
“Translation is the Art of Negotiating with Words”, in Hassad aS-Sineen(Harvest of Years): Essays in Teaching Translation
...Show More Authors

Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
The influence of cold atmospheric pressure plasma on TSH and thyroid hormones in male rats
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Sep 10 2018
Journal Name
Iraqi Journal Of Physics
The influence of magnetic field and cathode dimensions on plasma characteristics in hollow cathode system
...Show More Authors

Experimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Achieving a theoretical approximation characterize the stopping power of heavy ion in D-T plasma
...Show More Authors

The dependence of the energy losses or the stopping power for the ion contribution in D- T hot plasma fuels upon the corresponding energies and the related penetrating factorare arrive by using by a theoretical approximation models. In this work we reach a compatible agreement between our results and the corresponding experimental results.

View Publication Preview PDF
Scopus
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref (1)
Crossref