Preferred Language
Articles
/
14YHdYYBIXToZYALD4qe
Simulation and experimentation study on the performance of metal hydride storage vessels
...Show More Authors

This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure damage owing to the FEA analysis that was performed. The cooling chamber, although producing minor leaks due to design oversight, increased performance dramatically, showing a reduction in internal powder temperature from 130°C, down to 25°C during the absorption process, as well as reducing the absorption time down from 30 minutes to just over 5 minutes. The novel idea of implanting a sheathed thermocouple into the centre of the hydride powder proved to be highly valuable asset and provided important information, especially during desorption where the outside container could be heating up, while the inner powder is still cooling down, data that have not been seen before.

Scopus Clarivate Crossref
Publication Date
Wed Jun 28 2023
Journal Name
Engineering Applications Of Computational Fluid Mechanics
Comprehensive analysis of melting enhancement by circular Y-shaped fins in a vertical shell-and-tube heat storage system
...Show More Authors

View Publication
Scopus (21)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Aug 04 2022
Journal Name
Contemporary Nurse
ICU nurses’ safety performance related to respect for safety and management commitment: A cross-sectional study
...Show More Authors

View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Heliyon
A comprehensive review on modelling the adsorption process for heavy metal removal from waste water using artificial neural network technique
...Show More Authors

View Publication Preview PDF
Scopus (44)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Improving Voltage Stability in Kurdistan Power System in Areas with Deficit Power Production by Rescheduling the Active Power Based on PSS/E Simulation
...Show More Authors

This paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Study the effect of thickness and annealing temperature on the Electrical Properties of CdTe thin Films
...Show More Authors

The electrical properties of polycrystalline cadmium telluride thin films of different thickness (200,300,400)nm deposited by thermal evaporation onto glass substrates at room temperature and treated at different annealing temperature (373, 423, 473) K are reported. Conductivity measurements have been showed that the conductivity increases from 5.69X10-5 to 0.0011, 0.0001 (?.cm)-1 when the film thickness and annealing temperature increase respectively. This increasing in ?d.c due to increasing the carrier concentration which result from the excess free Te in these films.

View Publication Preview PDF
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Journal Of Economics And Administrative Sciences
The Impact of Developmental Leadership on Adaptive Performance- Analytical Research General Directorates of Education in Baghdad province
...Show More Authors

The research aims to reveal the impact of developmental leadership in its dimensions (ideal model, interest in employees, inspiration and motivation) as an independent variable in achieving adaptive performance in its dimensions (Creative problem solving, learning and motivation, Training efforts, adaptability, work stress management, dealing with crises and emergencies) as a dependent variable, and the research aims to enhance the quality of developmental leadership in the research sample through this leadership style, which is a modern style and is still under research and study with a focus on the benefit of adaptive performance From a psychological and organizational research sample consisting of (106) respondents from the middle adm

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Physical Education
The Effect Of Compound Exercises Using Visual Training Aid On Tactical Performance Of Deaf Soccer League Players
...Show More Authors

S Ali…, Journal of Physical Education, 2019 - Cited by 1

View Publication
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
Numerical Investigation of the Effect of Inserted Twisted Tape inside Submerged Bundle Tubes on its Thermal Performance
...Show More Authors

Twisted tape insertion in the smooth plain tube is one of the types of passive methods that are used to enhance heat transfer. Swirl fluid flow inside the tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with a twisted tape of twist ratio of y = (H/D) = (150/17) =8.8 along the plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nus

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 04 2024
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of intellectual capital on sustainable competitive performance: field research in a sample of private colleges
...Show More Authors

Abstract:

                  This research seeks to test the influence of intellectual capital as an explanatory variable and its components (human capital, structural capital, relational capital) and sustainable competitive performance as a responsive variable and its components (reducing service delivery cycle time, rapid response to market demand, increasing customer satisfaction, providing better Quality of service, increasing market share)” through a field study, and here the research problem was diagnosed in an attempt to answer the following question: Is there awareness among the senior management within the private colle

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Numerical Investigation of the Effect of Inserted Twisted Tape inside Submerged Bundle Tubes on its Thermal Performance
...Show More Authors

Twisted tape insertion in smooth plain tube is one of types of passive methods that is used to enhance heat transfer. Swirl fluid flow inside tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with twisted tape has twist ratio of y = (H/D) = (150/17) =8.8 along with a plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nusselt number

... Show More
View Publication Preview PDF
Crossref