atrogenic atrial septal defect (IASD), post Catheter ablation during electrophysiological study simply can be assess with Echocardiography nowadays ablation consider the main line in the managements of patients with various type of arrhythmia. This study aims to de-termine the outcomes of Iatrogenic Atrial Septal Defect (IASD) six months post radiofrequency ablation (RF) procedure of left atrial arrhythmia using non-invasive Transtho-racic Echocardiography (TTE) parameters (LVEF, E/e` and ASD size) with sheath size as predictors of atrial septal defect closure. Patients and methods: A prospective study was con-ducted in Iraqi Centre for Heart Diseases included 47 patients post Electrophysiology procedure and ablation of left atrial SVT were selected after non complicated tran-septal puncture using two size of sheath in three type of arrythmia and follow up done simply with Transthoracic echocardiography (TTE) was used to evaluate the atrial septal defect (ASD) (from May 2019-May 2020) in Iraqi centre for heart diseases. Results: After Electrophysiology study, results of this study were analysed and collected according to duration of procedure, sheath size and number that used in sep-tostomy, size of IASD and Echocardiographic parameters. The mean age of the patients (36.28±10.34 years), males were 23 (48.9%) while females were 24 (51.1%), without structural heart diseases and good LV function with mean EF (64.68± 5.23%). Iatrogenic atrial septal defects (IAS-Ds)were detected by TTE in all patients with range from (2-5) mm with mean of (3.47±0.92), performed by Trans-septal puncture (TSP), either with single 8 French sheath in 24 (51.06%) patients or single 12 French sheath in 17 (36.17%) patients while 6 (12.77%) patients the defect was performed by double transseptal sheath. spontane-ous closure occur in 35(74%) patients within first three months with clear significant association between size of ASD that related to the sheath size and duration of procedure (P<0.0001). We notice that some Echocardiographic parameters were also associated with IASD without any clinical complications and/ or deterioration. Conclusions: post catheter ablation number and size of sheath and duration of ablation consider as a predictor to closure of residual atrial septal defect post atrial sep-tostomy and can simply assess with non-invasive Trans-thoracic Echocardiography parameters such (Atrial septal defect size and body surface area) during initial six months follow up. © 2021, Venezuelan Society of Pharmacology and Clinical and Therapeutic Pharmacology. All rights reserved.
The preparation of low cost activated carbon from date stones and microwave method by using K2CO3 as chemical activator were investigated.
The prepared activated carbon was used to remove fluoroquinolones antibiotics from aqueous solution. The characterizations of the activated carbon is represented by surface area, pore volume, ash content, moisture content, bulk density, and iodine number. The adsorbed fluoroquinolones antibiotics are Ciprofloxcin (CIP), Norfloxcin (NOR) and Levofloxcin (LEVO). Different variables as pH, initial concentrations and contact time were studied to show the efficieny of prepared activated carbon. The experimental adsorption data were analyzed by Lungmuir, Freundlich
... Show MoreAbstract
Metal cutting processes still represent the largest class of manufacturing operations. Turning is the most commonly employed material removal process. This research focuses on analysis of the thermal field of the oblique machining process. Finite element method (FEM) software DEFORM 3D V10.2 was used together with experimental work carried out using infrared image equipment, which include both hardware and software simulations. The thermal experiments are conducted with AA6063-T6, using different tool obliquity, cutting speeds and feed rates. The results show that the temperature relatively decreased when tool obliquity increases at different cutting speeds and feed rates, also it
... Show MoreA laboratory investigation of six different tests were conducted on silty clay soil spiked with lead in concentrations of 1500 mg/kg. A constant DC voltage gradient of 1 V/cm was applied for all these tests with duration of 7 days remediation process for each test. Different purging solutions and addition configurations, i.e. injection wells, were investigated experimentally to enhance the removal of lead from Iraqi soil during electro-kinetic remediation process. The experimental results showed that the overall removal efficiency of lead for tests conducted with distilled water, 0.1 M acetic acid, 0.2 M EDTA and 1 M ammonium citrate as the purging solutions were equal to 18 %, 37 %, 42 %, and 29 %, respectively. H
... Show MoreThe degradation performance of aqueous solution of pesticide Alachlor has been studied at solar pilot scale plant in two photocatalytic systems: homogeneous photocatalysis by photo-Fenton and heterogeneous photocatalysis with titanium dioxide. The pilot scale system included of compound parabolic collectors specially designed for solar photocatalytic applications, and installed at University of Baghdad, Department of Environmental Engineering back yard. The influence of different concentrations, H2O2 (200-2400 mg/l), Fe+2(5- 30 mg/l) and TiO2 (100-500 mg/l) and their relationship with the degradation efficiency were studied.
The COD removal efficienc
... Show MoreThis work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia
Variable selection is an essential and necessary task in the statistical modeling field. Several studies have triedto develop and standardize the process of variable selection, but it isdifficultto do so. The first question a researcher needs to ask himself/herself what are the most significant variables that should be used to describe a given dataset’s response. In thispaper, a new method for variable selection using Gibbs sampler techniqueshas beendeveloped.First, the model is defined, and the posterior distributions for all the parameters are derived.The new variable selection methodis tested usingfour simulation datasets. The new approachiscompared with some existingtechniques: Ordinary Least Squared (OLS), Least Absolute Shrinkage
... Show MoreThe issue of image captioning, which comprises automatic text generation to understand an image’s visual information, has become feasible with the developments in object recognition and image classification. Deep learning has received much interest from the scientific community and can be very useful in real-world applications. The proposed image captioning approach involves the use of Convolution Neural Network (CNN) pre-trained models combined with Long Short Term Memory (LSTM) to generate image captions. The process includes two stages. The first stage entails training the CNN-LSTM models using baseline hyper-parameters and the second stage encompasses training CNN-LSTM models by optimizing and adjusting the hyper-parameters of
... Show MoreIn this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,
... Show MoreTo accommodate utilities in buildings, different sizes of openings are provided in the web of reinforced concrete deep beams, which cause reductions in the beam strength and stiffness. This paper aims to investigate experimentally and numerically the effectiveness of using carbon fiber reinforced polymer (CFRP) strips, as a strengthening technique, to externally strengthen reinforced concrete continuous deep beams (RCCDBs) with large openings. The experimental work included testing three RCCDBs under five-point bending. A reference specimen was prepared without openings to explore the reductions in strength and stiffness after providing large openings. Openings were created symmetrically at the center of spans of the other specimens
... Show More