atrogenic atrial septal defect (IASD), post Catheter ablation during electrophysiological study simply can be assess with Echocardiography nowadays ablation consider the main line in the managements of patients with various type of arrhythmia. This study aims to de-termine the outcomes of Iatrogenic Atrial Septal Defect (IASD) six months post radiofrequency ablation (RF) procedure of left atrial arrhythmia using non-invasive Transtho-racic Echocardiography (TTE) parameters (LVEF, E/e` and ASD size) with sheath size as predictors of atrial septal defect closure. Patients and methods: A prospective study was con-ducted in Iraqi Centre for Heart Diseases included 47 patients post Electrophysiology procedure and ablation of left atrial SVT were selected after non complicated tran-septal puncture using two size of sheath in three type of arrythmia and follow up done simply with Transthoracic echocardiography (TTE) was used to evaluate the atrial septal defect (ASD) (from May 2019-May 2020) in Iraqi centre for heart diseases. Results: After Electrophysiology study, results of this study were analysed and collected according to duration of procedure, sheath size and number that used in sep-tostomy, size of IASD and Echocardiographic parameters. The mean age of the patients (36.28±10.34 years), males were 23 (48.9%) while females were 24 (51.1%), without structural heart diseases and good LV function with mean EF (64.68± 5.23%). Iatrogenic atrial septal defects (IAS-Ds)were detected by TTE in all patients with range from (2-5) mm with mean of (3.47±0.92), performed by Trans-septal puncture (TSP), either with single 8 French sheath in 24 (51.06%) patients or single 12 French sheath in 17 (36.17%) patients while 6 (12.77%) patients the defect was performed by double transseptal sheath. spontane-ous closure occur in 35(74%) patients within first three months with clear significant association between size of ASD that related to the sheath size and duration of procedure (P<0.0001). We notice that some Echocardiographic parameters were also associated with IASD without any clinical complications and/ or deterioration. Conclusions: post catheter ablation number and size of sheath and duration of ablation consider as a predictor to closure of residual atrial septal defect post atrial sep-tostomy and can simply assess with non-invasive Trans-thoracic Echocardiography parameters such (Atrial septal defect size and body surface area) during initial six months follow up. © 2021, Venezuelan Society of Pharmacology and Clinical and Therapeutic Pharmacology. All rights reserved.
Background: A wound is defined as a break or damage in the skin, resulting from physical or thermal damage or as a result of the presence of an underlying medical or physical condition. Herbal medicine can be called one of the branches of medicine in various forms.Phyllunthus amarus is a small herb well known for its medicinal properties and widely used worldwide. P. amarus is an important plant of Indian Ayurvedic system of medicine. Fibronectin is a major component of the extracellular matrix. It is secreted by various cells, primarily fibroblasts, as a soluble protein dimer and is then assembled into an insoluble matrix in a complex cell-mediated process. Materials and methods: Forty rats will be subjected for a surgical operation
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show MoreThis study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreBackground: The mechanical properties of 3D-printed denture base resins are crucial factors for determining the quality and performance of dentures inside a patient’s mouth. Tensile strength and diametral compressive strength are two properties that could play significant roles in assessing the suitability of a material. Although they measure different aspects of material behavior, a conceptual link exists between them in terms of overall material strength and resilience. Aim: This study aims to investigate the correlation between tensile strength and diametral compressive strength after incorporating 2% ZrO2 nanoparticles (NPs) by weight into 3D-printed denture base resin. Methods: A total of 40 specimens (20 dumbbell-shaped and
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi
... Show MoreAvascular necrosis have always presented great challenges to orthopedic surgeons and patients, remain in many ways today the unsolved dilemma. Varieties of non-vascularized bone grafting techniques preceded by core decompression have been proposed with varying degrees of success. O bb j ee cc t i vv ee ss : The aim of this study is to review the the value of core decompression and non-vascularized tibial bone strip graft treatment for early stages of non-traumatic osteonecrosis stage II & III according to stein burg staging . M ee t hh oo dd ss : prospectively reviewed 26 patients (32 hips) with osteonecrosis of the femoral head between June 2006 and December 2013 at Imam Ali hospital in Sader city & Al-Wasity teaching hosp
... Show MoreThe electrical insulation of the manufacture sulfonated phenol-formaldehyde viscous material (product) has been studied with Polyvinyl-acetate (PVA) and toluene diisocyanate (TDI) blend has been prepared by fixing percentage by weight 3:1 and mixed with different percentages by weight of the product sulfonated phenol formaldehyde viscous mass (SPF). The Fourier transform infrared (FTIR) spectroscopy is done on (SPF) resin powder and prepared film of PVA-TDI-SPF viscous mass. The quality factor (Q), dissipation factor (D), parallel resistance (Rp), series resistance (Rs), parallel capacitance (Cp), series capacitance (Cs) and phase shift (?) are measured. The calculated maximum dielectric constant (??) is 3.49x107 at sample (1) wt.1% SPF vis
... Show More