atrogenic atrial septal defect (IASD), post Catheter ablation during electrophysiological study simply can be assess with Echocardiography nowadays ablation consider the main line in the managements of patients with various type of arrhythmia. This study aims to de-termine the outcomes of Iatrogenic Atrial Septal Defect (IASD) six months post radiofrequency ablation (RF) procedure of left atrial arrhythmia using non-invasive Transtho-racic Echocardiography (TTE) parameters (LVEF, E/e` and ASD size) with sheath size as predictors of atrial septal defect closure. Patients and methods: A prospective study was con-ducted in Iraqi Centre for Heart Diseases included 47 patients post Electrophysiology procedure and ablation of left atrial SVT were selected after non complicated tran-septal puncture using two size of sheath in three type of arrythmia and follow up done simply with Transthoracic echocardiography (TTE) was used to evaluate the atrial septal defect (ASD) (from May 2019-May 2020) in Iraqi centre for heart diseases. Results: After Electrophysiology study, results of this study were analysed and collected according to duration of procedure, sheath size and number that used in sep-tostomy, size of IASD and Echocardiographic parameters. The mean age of the patients (36.28±10.34 years), males were 23 (48.9%) while females were 24 (51.1%), without structural heart diseases and good LV function with mean EF (64.68± 5.23%). Iatrogenic atrial septal defects (IAS-Ds)were detected by TTE in all patients with range from (2-5) mm with mean of (3.47±0.92), performed by Trans-septal puncture (TSP), either with single 8 French sheath in 24 (51.06%) patients or single 12 French sheath in 17 (36.17%) patients while 6 (12.77%) patients the defect was performed by double transseptal sheath. spontane-ous closure occur in 35(74%) patients within first three months with clear significant association between size of ASD that related to the sheath size and duration of procedure (P<0.0001). We notice that some Echocardiographic parameters were also associated with IASD without any clinical complications and/ or deterioration. Conclusions: post catheter ablation number and size of sheath and duration of ablation consider as a predictor to closure of residual atrial septal defect post atrial sep-tostomy and can simply assess with non-invasive Trans-thoracic Echocardiography parameters such (Atrial septal defect size and body surface area) during initial six months follow up. © 2021, Venezuelan Society of Pharmacology and Clinical and Therapeutic Pharmacology. All rights reserved.
In this paper, we derived an estimators and parameters of Reliability and Hazard function of new mix distribution ( Rayleigh- Logarithmic) with two parameters and increasing failure rate using Bayes Method with Square Error Loss function and Jeffery and conditional probability random variable of observation. The main objective of this study is to find the efficiency of the derived of Bayesian estimator compared to the to the Maximum Likelihood of this function using Simulation technique by Monte Carlo method under different Rayleigh- Logarithmic parameter and sample sizes. The consequences have shown that Bayes estimator has been more efficient than the maximum likelihood estimator in all sample sizes with application
The idea of using slender Reinforced Concrete (RC) columns with cross-shaped (+-shaped) instead of columns with square-shaped was discussed in this paper. The use of +-shaped columns provides many architectural and structural advantages, such as avoiding prominent columns edges and improved the structural response of member. Therefore, this study explores the structural response of slender +-shaped columns experimentally and numerically by nonlinear finite element analysis using Abaqus simulation tools. The results showed an excellent convergence in strength between numerical and test results with an average standard deviation of 0.05 and 0.07. Besides that, the use of +-shaped column
Experimental and numerical studies have been conducted on the effects of bed roughness elements such as cubic and T-section elements that are regularly half-channel arrayed on one side of the river on turbulent flow characteristics and bed erosion downstream of the roughness elements. The experimental study has been done for two types of bed roughness elements (cubic and T-section shape) to study the effect of these elements on the velocity profile downstream the elements with respect to different water flow discharges and water depths. A comparison between the cubic and T-section artificial bed roughness showed that the velocity profile downstream the T-section increased in smooth side from the river and decrease in the rough side
... Show MoreBackground: Contact between implant material and bones must be strong and fast creation, to fulfill these properties appropriate surface modifications must apply on used implants. In this contribution; double surface modifications are applied on Ti-6Al-4V alloy to accelerate osseointegration. Materials and methods: Anodic process is utilized to create titania nanotubes (TNTs) on the screws made from Ti-6Al-4V alloy. These implants were coated with nano ZrO2 particles. Second modification was annealing anodized screws at 8000C, and implanted in tibiae of nine adult New Zealand white rabbits. Results: Physical and histological consequences of two surface modifications on Ti-6Al-4V alloy screws were studied. Scanning electron microscope (SEM)
... Show More