Preferred Language
Articles
/
0xeBeI0BVTCNdQwCLBQG
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL- 1, 0.05 μg. mL-1 and 0.032 (n=10) respectively. The PF (Preconcentration factor) obtained for the proposed method in 98% is 75. The intra-day and interday precisions were 2.1% and 3.6% (for 1.0 μg mL-1, n=10). The relative standard deviation R.S.D for 1.0 μg mL-1 is 1.26 (n=10). The proposed method has been successfully applied for the determination of theophylline in the pharmaceutical preparations.

View Publication
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Clonazepam in Pure and Dosage forms using Charge Transfer Reaction
...Show More Authors

A rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine And Public Health
SPECTROPHOTOMETRIC DETERMINATION OF DIPHENHYDRAMINE HCL IN PURE AND PHARMACEUTICAL FORMULATIONS USING THYMOL BLUE
...Show More Authors

This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo

... Show More
View Publication
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Visual pollution and statistical determination in some of Karrada district main streets /Baghdad
...Show More Authors

This study objective is to identify the visual pollution in Karrada district main streets as an example of main streets in Baghdad, the public opinion about each pollutants, solutions to reduce and eliminate the pollution were suggested as well. In order to accomplish this objective different methods were used, 16 pollutants were selected, pictures of each pollutants were taken and a questioner were distributed randomly for 270 people to evaluate the public opinion with statistical methods. Garbage, their disposal and storage areas took the first two places as the highest offensive pollutants. The people showed that they find long lines of vehicles, debris and generators appearance ranked third, fourth and fifth respectively .This resear

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive Spectrophotometric Determination of Doxycycline in Pure and Dosage Forms using p-Bromanil
...Show More Authors

View Publication
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Improvement of Asphalt Concrete Mixtures by Adding Pulverised Fuel Ash as Filler
...Show More Authors

Consuming of by-product or waste materials in highway engineering is significant in the construction of new roads and/or in renovations of the existing ones. Pulverised Fuel ash (PFA), which is a by-product material of burning coal in power stations, is one of these materials that might be incorporated instead of mineral filler in hot asphalt mixtures.

Two types of surface course mixtures have been prepared one with conventional mineral filler i.e. ordinary Portland cement (OPC) while the second was with PFA. Several testings have been conducted to indicate the mechanical properties which were Marshall Stability and Indirect Tensile Strength tests. On the other hand, moisture damage and ageing have been evaluated

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Removal of Water Turbidity by using Aluminum Filings as a Filter Media
...Show More Authors

The ability of using aluminum filings which is locally solid waste was tested as a mono media in gravity rapid filter. The present study was conducted to evaluate the effect of variation of influent water turbidity (10, 20and 30 NTU); flow rate(30, 40, and 60 l/hr) and bed height (30and60)cm on the performance of aluminum filings filter media for 5 hours run time and compare it with the conventional sand filter. The results indicated that aluminum filings filter showed better performance than sand filter in the removal of turbidity and in the reduction of head loss. Results showed that the statistical model developed by the multiple linear regression was proved to be
valid, and it could be used to predict head loss in aluminum filings

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation of Alpha Tocopherol Acetate as a Powder Dosage Form by Adsorption
...Show More Authors

Alpha-tocopherol acetate is one of the most important vitamin E derivatives,that were used  as antioxidants. Adsorbents like kaolin, magnesium carbonate, and microcrystalline cellulose were used successfully to incorporate oily alpha-tocopherol acetate into an acceptable powder dosage form. The results revealed that microcrystalline cellulose as an adsorbents gave the best results with 50% loading capacity at time, 8 minutes before and after incubation period (3 months at 30C°), while kaolin and magnesium carbonate have been shown a significant difference before and after incubation. Addition of 1% w/w magnesium carbonate to the kaolin enhanced the loading capacity by decreasing the time of adsorption from 20 to 6 minutes and 47

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Computers & Electrical Engineering
A new proposed statistical feature extraction method in speech emotion recognition
...Show More Authors

View Publication
Scopus (42)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2011
Journal Name
Journal Of Faculty Of Medicine Baghdad
The correlation between FEV1/ FVC with Arm span to height or chest to waist ratio as an index of pulmonary function in healthy subject.
...Show More Authors

Abstract