new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL- 1, 0.05 μg. mL-1 and 0.032 (n=10) respectively. The PF (Preconcentration factor) obtained for the proposed method in 98% is 75. The intra-day and interday precisions were 2.1% and 3.6% (for 1.0 μg mL-1, n=10). The relative standard deviation R.S.D for 1.0 μg mL-1 is 1.26 (n=10). The proposed method has been successfully applied for the determination of theophylline in the pharmaceutical preparations.
Background: Carpal tunnel syndrome (CTS) is the most prevalent upper-limb entrapped neuropathy. A nerve conduction study (NCS) is the simplest method for identifying CTS when combined with a satisfactory clinical assessment and physical assessment. Ultrasound is a beneficial non-traumatic screening approach for CTS and there is a relationship between the NCS tests and the measures of CSA by ultrasound. Objective: to assess whether or not sonographic observations of the median nerve seems to be varied amongst DM and non-DM CTS individual. Patients and methods: The total of 50 non-DM Individuals with CTS and 50 DM individuals with CTS have been included in this study. All individuals were submitted to full medical assessment NCS testi
... Show MoreTo detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the str
... Show More