Preferred Language
Articles
/
0xe4ZJABVTCNdQwCKohy
Evaluation of Quorum-Sensing, Antibiotics Resistance, and Biofilm Formation in Pathogenic Bacteria from the Hospital Environments
...Show More Authors

Abstract Background: Multidrug-resistant bacteria (MDR) often contaminate hospital environment and cause serious illnesses. Quorum Sensing (QS) regulates a variety of downstream cellular processes, including antibiotics resistance mechanisms and biofilm formation, and causes harm to the host. This study investigates antibacterial susceptibility and biofilm formation of pathogenic bacteria in hospital environment. Methods: Hundred bacterial isolates were collected from various environments in the Medical City hospital. The antimicrobial susceptibility technique was evaluated through disk diffusion method. Next, biofilms formation was detected by the microliter plate assay. Finally, PCR was used to analyze the frequency of QS system genes. Results: Current findings showed that the predominant isolates were Acinetobacter baumannii (34%), Escherichia coli (30%), Pseudomonas aeruginosa (19%), and Klebsiella pneumonia (17%). In general, significant resistance was found related to trimethoprim (88%), Augmentin (88%), and cefotaxime (72%). Among all isolates, 62% of sensitivity was related to ciprofloxacin. Biofilm had been formed by 39% of isolates. PCR results showed that the frequency of lasI and rhlI gene was 70% and 61%, respectively. Conclusion: Current findings revealed that the hospital environment is a potential reservoir of MDR gram-negative pathogenic bacteria. Thus, we suggest that the health policymakers in Iraq must critically apply the guidelines and recommendations for monitoring the environments in the health sector. Keywords: Antibiotics Footprint, Acinetobacter baumannii, Antibiotics Resistance, Quorum-Sensing, PCR.

Scopus
Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 29 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Cyclic Fatigue Resistance of Wave One Gold, F6 SkyTaper, One Curve, and AF Blue R3 NiTi Rotary Instrumentation Systems
...Show More Authors

Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to frac

... Show More
Scopus (1)
Scopus
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Science,
Monitoring Vegetation Growth of Spectrally Landsat Satellite Imagery ETM+ 7 & TM 5 for Western Region of Iraq by Using Remote Sensing Techniques.
...Show More Authors

Landsat-5 Thematic Mapper (TM) has been imaging the Earth since March 1984 and Landsat-7 Enhanced Thematic Mapper Plus (ETM+) was added to the series of Landsat instruments in April 1999. In this paper the two sensors are used to monitoring the agriculture condition and detection the changing in the area of plant covers, the stability and calibration of the ETM+ has been monitored extensively since launch although it is not monitored for many years, TM now has a similar system in place to monitor stability and calibration. By referring to statistical values for the classification process, the results indicated that the state of vegetation in 1990 was in the proportion of 42.8%, while this percentage rose to 52.5% for the same study area in

... Show More
View Publication
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 05 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EVALUATION OF CHEMICAL AND MICROBIAL QUALITY FOR SOME BOTTLED WATER THAT AVAIABLE IN LOCAL MARKETS: EVALUATION OF CHEMICAL AND MICROBIAL QUALITY FOR SOME BOTTLED WATER THAT AVAIABLE IN LOCAL MARKETS
...Show More Authors

This study was conducted to evaluate the bottled water quality for the six-producing companies in Baghdad city, where selected six brands which are the most marketed in the Iraqi market, especially in Baghdad, where taking the proper amount of bottled water in September 2015 and included the studied characteristics (EC , pH ,TDS, Turbidity, Ca+2, Mg+2, Cl-, No3-, So4-2, HCO3-, Na+ and K+) in addition to the total population of bacteria aerobic and coliform, and compare the results with the standard specifications of the Iraqi and the World Health Organization (WHO), as well as to compare the results of sampling specifications mentioned on the packaging by the producing companies. The results showed the presence of high significant differ

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
EXTRACTING PECTIN FROM TOMATOES AND BEET PEELS AND USING IT IN THE MANUFACTURE OF YOGURT AND COMPARING THEM
...Show More Authors

Pectin is available in many plants and in this study, the peels of tomatoes and beet were used to be an economical source of pectin production instead of dumping it with waste or using it as animal feed. The pectin extracted from the peels using different solutions, namely citric acid (2 M), oxalic acid (2%) and hydrochloric acid (0.5 M) the outcome of the extraction methods, 7. 1%, 6% and 11% respectively for tomatoes peels, while the pectin of beet peels were 8%, 6.5%, and 8.3%, and the highest percentage obtained in the manner of hydrochloric acid adopted in the manufacture of yogurt.Yogurt was manufactured with four treatments, in the first treatment standard pectin was added and the second treatment in addition to the pectin extracted

... Show More
Scopus
Publication Date
Thu Feb 23 2023
Journal Name
Chalcogenide Letters
Fabrication and evaluation of CuAlSe2/Si photodetector
...Show More Authors

In this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Design and Evaluation of a Polarizer Filter
...Show More Authors

This research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.

View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Flurbiprofen Oral Film
...Show More Authors

Fast dissolving film can be defined as a dosage form, which when placed in the oral cavity. It will rapidly disintegrate and dissolves to release the medication for oral mucosal absorption or allow for the gastrointestinal absorption to be achieved when swallowed.

Flurbiprofen is non-steroidal anti-inflammatory agent with antipyretic and analgesic properties and can be used   in low doses 8.75 mg as analgesic and anti inflammatory agent in sore throat infection. This study aims to   formulate flurbiprofen as oral dissolving films,   to improve the effective relief of pain with severe sore throats with little or no adverse effect.

Nine formulas were prepared using solvent-casting method, and t

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Apr 06 2017
Journal Name
Chalcogenide Letters
CdS/PMMA-based inorganic/organic heterojunction for H<sub>2</sub>S gas sensing
...Show More Authors

The performance of H2S sensor based on poly methyl methacrylate (PMMA)-CdS nanocomposite fabricated by spray pyrolysis technique has been reported. XRD pattern diffraction peaks of nano CdS has been indexed to the hexagonally wurtzite structured The nanocomposite exhibits semiconducting behavior with optical energy gap of4.06eV.SEM morphology appears almost tubes like with CdS/PMMA network. That means the addition of CdS to polymer increases the roughness in the film and provides high surface to volume ratio, which helps gas molecule to adsorb on these tubes. The resistance of PMMA-CdS nanocomposite showed a considerable change when exposed to H2S gas. Fast response time to detect H2S gas was achieved by using PMMA-CdS thin film sensor. The

... Show More
Publication Date
Fri Nov 04 2022
Journal Name
Journal Of Optics
Coreless optical fiber for hemoglobin (HB) sensing with bilayer based on surface plasmon resonance
...Show More Authors

In this work, an optical fiber biomedical sensor for detecting the ratio of the hemoglobin in the blood is presented. A surface plasmon resonance (SPR)-based coreless optical fiber was developed and implemented using single- and multi-mode optical fibers. The sensor is also utilized to evaluate refractive indices and concentrations of hemoglobin in blood samples, with 40 nm thickness of (20 nm Au and 20 nm Ag) to increase the sensitivity. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref