Preferred Language
Articles
/
0xaReocBVTCNdQwCYVPs
PROPERTIES OF JOVIAN RADIO BURSTS AT FREQUENCY 20.1 MHZ
...Show More Authors

In this paper, a study was made to determine the properties of Jovian radio bursts emitted at frequency 20.1MHZ. The data were provided from the Radio Jove archive for twelve years (2000-2012) for multi stations. The duration time for Long bursts (L) was (10-30) seconds and for Short bursts (S) was (10-20) seconds. The effect of radio bursts from the Sun and the galactic background were calculated at the same frequency and were found that radio bursts from the Sun will reduce the occurrence probability of Jovian radio bursts much more than radio bursts from the galactic background. The distribution of Jovian radio bursts was different; the occurrence probability with respect to the northern latitudes was more than the southern latitudes.

Publication Date
Fri Oct 01 2010
Journal Name
Radiation Effects And Defects In Solids
An automated autocorrelator for the measurement of high-frequency femtosecond pulses
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Dec 12 2003
Journal Name
Iraqi Journal Of Laser
Frequency Doubled Nd: YAG Laser for the Treatment of Diabetic Retinopathy
...Show More Authors

The present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
The frequency of hypoglycemia in macrosomic neonates in Amarah governorate, Iraq
...Show More Authors

Background: Neonatal macrosomia is defined as a birth weight of more than 4000 g. Significant maternal and neonatal complications can result from the birth of macrosomic infants like hypoglycemia and birth injuries.Objectives: To determine the frequency of hypoglycemia in neonates with macrosomia in Amarah, IraqMethods: The study involved 146 macrosomic newborn neonates delivered in 2 maternity hospitals in Amarah, Iraq during a period from June 2011 to June 2014.Results: Hypoglycemia was observed in 16% of neonates affected by macrosomia. Maternal diabetes was the most common cause of fetal macrosomia (28%).Our results were compared with those from other parts of the world.Conclusion Macrosomia is associated with increase rate ofneonata

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
A Hybrid Coefficient Decimation- Interpolation Based Reconfigurable Low Complexity Filter Bank for Cognitive Radio
...Show More Authors

Non uniform channelization is a crucial task in cognitive radio receivers for obtaining separate channels from the digitized wideband input signal at different intervals of time. The two main requirements in the channelizer are reconfigurability and low complexity. In this paper, a reconfigurable architecture based on a combination of Improved Coefficient Decimation Method (ICDM) and Coefficient Interpolation Method (CIM) is proposed. The proposed Hybrid Coefficient Decimation-Interpolation Method (HCDIM) based filter bank (FB) is able to realize the same number of channels realized using (ICDM) but with a maximum decimation factor divided by the interpolation factor (L), which leads to less deterioration in stop band at

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2024
Journal Name
Journal Of Physics: Conference Series
Studying the effect of changing optical fibers parameters on their modes properties at 1000 nm wavelength
...Show More Authors
Abstract<p>Optical fiber technology is without a doubt one of the most significant phases of the communications revolution and is crucial to our daily lives. Using the free version (2022) of RP Fiber Calculator, the modal properties for optical fibers with core radii (1.5−7.5) μm, core index (1.44−1.48) and cladding index (1.43−1.47) have been determined at a wavelength of 1000 nm. When the fiber core’s radius is larger than its operating wavelength, multimode fibers can be created. The result is a single-mode fiber in all other cases. All of the calculated properties, it has been shown, increase with increasing core radius. The modes’ intensity profiles were displayed.</p>
View Publication
Scopus Crossref
Publication Date
Sun Dec 01 2013
Journal Name
2013 Ieee International Rf And Microwave Conference (rfm)
Differential Evolution algorithm for linear frequency modulation radar signal denoising
...Show More Authors

Signal denoising is directly related to sample estimation of received signals, either by estimating the equation parameters for the target reflections or the surrounding noise and clutter accompanying the data of interest. Radar signals recorded using analogue or digital devices are not immune to noise. Random or white noise with no coherency is mainly produced in the form of random electrons, and caused by heat, environment, and stray circuitry loses. These factors influence the output signal voltage, thus creating detectable noise. Differential Evolution (DE) is an effectual, competent, and robust optimisation method used to solve different problems in the engineering and scientific domains, such as in signal processing. This paper looks

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
The Use of Pulse Frequency Modulation Technique for Optical Video Communication System
...Show More Authors

An optical video communication system is designed and constructed using pulse frequency modulation (PFM) technique. In this work PFM pulses are generated at the transmitter using voltage control oscillator (VCO) of width 50 ns for each pulse. Double frequency, equal width and narrow pulses are produced in the receiver be for demodulation. The use of the frequency doubling technique in such a system results in a narrow transmission bandwidth (25 ns) and high receiver sensitivity.

View Publication Preview PDF
Publication Date
Sun Jan 04 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The frequency of penile acne among Iraqi males with facial acne vulgaris
...Show More Authors

Background: Acne vulgaris is a common skin problem. It affects areas of high density of sebaceous glands like the face, chest and back. The penile skin is no exception, also can be affected with acne, however little was written on this subject.<br />Patients & Methods: This is a clinical epidemiological study conducted at the Department of Dermatology & Venereology- Baghdad Teaching Hospital, during the period between December 2007 and May 2008. Seventy six male patients with facial acne vulgaris were enrolled in the study. A full history includes age, age of onset of facial acne and any penile lesion observed by the patient Examination of the face was done for the severity of acne and grading it into mild, moderate, severe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Food Frequency Intake and Dietary Habits for Diabetic Pregnant Women
...Show More Authors

Objective: The study aims at assessing the food frequency intake and dietary habits for diabetic pregnant
women.
Methodology: A descriptive study is carried out for the period from November4th 2013 to August
25th 2014. A purposive "non-probability" sample of one hundred diabetic pregnant women is selected from
the Diabetic and Endocrine Center in Al-Amarha City. A questionnaire is developed as a tool of data
collection. Content validity of the study instrument is determined through panel of experts. Split-half
reliability technique is used for reliability determination of the study instrument which depicts a reliability
coefficient of (0.79) for the entire scale. A structured interview with each diabetic pregnant wom

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
A stuy Some physical properties for play (vunyl alcohol) in aquecous solution at four temperatures
...Show More Authors

The densities and visconsities of solutions of poly(vinyl alcohol)(PVA) molccuar weight (14)kg.mol-1in water up to 0.035%mol.kg-1

View Publication Preview PDF