Preferred Language
Articles
/
0hZqQ4cBVTCNdQwCCj7M
Comparison of Some Mechanical and Physical Properties of three Types of Impression Materials with Different Dental Implant Angulations
...Show More Authors

Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression material exhibited the higher mean values of tear strength, followed by ID group then PVS which showed the lowest mean value. For wettability test, Polyether group exhibited the lowest mean values of contact angle, followed by mean values of contact angle of ID group, while the PVS group showed the highest contact angle. There was a significant difference in the linear distance measurements between the two parallel impression coping/analogue assembly of the working models obtained by using (Identium, 3M ESPE ExpressPVS , 3M ESPE Permadyne polyether) the polyether impression materials provide higher tear strengths and lower wettability than elastomer impression materials and Identium material have acceptable tear strengths and wettability. All three experimental impression materials were distorted in both conditions (angled and parallel implant situations)

Crossref
View Publication
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Synthesis, Spectral Studies, and Theoretical Treatment of some New Metal Complexes with Tridentate Ligand (Schiff and Mannich Base)
...Show More Authors

New metal ions complexes of tridentate ligand (1-((dicyclohexylamino) methyl)-3-(1,5-dimethyl-3-oxo-2-phenyl-2,3-dihydro-1H-pyrzol-4-ylimino) indolin-2-one) have been synthesized and characterized by chemical-physical analysis. The ligand acts as a tridentate for the complexation reaction with all metal ions. The new complexes, possessing the general formula [M(L)Cl]Cl where M=[Ni(II), Cu(II), Zn(II), Pd(II), Cd(II), Pt(IV) and Hg(II) ] ,show tetrahedral geometry. All complexes ,except Pd(II) complex which has a square planar geometry and Pt(IV) which show an octahedral geometry. The geometry of the prepared compounds has been proposed in another method theoretically by using one of the calculation molecular programs (Hype

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 05 2025
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Synthesizing, characterization of some metal ion complexes with new azo dye and studying antioxidant and anticancer (MCF-7)
...Show More Authors

This new azo dye 7-(3-hydroxy-phenylazo)-quinoline-8-ol was subsequently used to prepare a series of complexes with the chlorides of Fe, Co, Zn, Ru, Rh and Cd. The compounds identified by 1H and 13C-NMR, FT-IR, UV-Vis, mass spectroscopy, as well as TGA, DSC, and C.H.N., conductivity, magnetic susceptibility, metal and chlorine content. The results showed that the ligand behaves in a trigonal behavior, and that the complexes gave tetrahedral, except for Fe, Ru and Rh octahedral was given, that all of them are non-electrolytes. The effectiveness of both the compounds in inhibiting free radicals was evaluated by the ability to act as an antioxidant was measured using DPPH as a free radical and gallic acid as a standard substance, the

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Sep 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of Silicon di oxide Nano -Fillers reinforcement on some properties of heat cure polymethyl methacrylate denture base material
...Show More Authors

Background: The purpose of this study was to evaluate the effect of addition of surface treated silicon dioxide Nano filler (SiO2) on some properties of heat cured acrylic resin denture base material (PMMA). The properties were impact strength, transvers strength, and surface hardness. Materials and methods: In addition to controlled group SiO2 powder was added to PMMA powder by weight in three different percentages 3%, 5% and 7%, mixed by probe ultra-sonication machine.120 specimens were constructed and divided into 3 groups according to the test (each group consist of 40 specimens) and each group was subdivided into 4 sub-groups according to the percentage of added SiO2 (finally each subgroup consist of 10 specimens). The tests conducte

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Mechanical and Histological Significance of Nano Hydroxyapatite and Nano Zirconium Oxide Coating On the Osseointegration of CP Ti Implants
...Show More Authors

Background: Dental implant considers a unique treatment option for the replacement of missing dentition. The new trend of implants is looking for materials which accelerate bone formation in bone implant interface and enhance osseointegration to provide immediate loading directly after placement and decrease the time period which is disturbs patients and uncomfortable. The aim of the study was to evaluate the effect of nano zirconium oxide (ZrO2) and nano hydroxyapatite (Hap) mixture coating of screw shaped commercially pure titanium (cpTi) implants on bond strength at the bone implant interface with torque removal test and histological analysis in comparison with non coated implants. Materials and methods: Forty screws were machined from c

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
Effect of Using Porcelanite as Partial Replacement of Fine Aggregate on Roller Compacted Concrete with Different Curing Methods
...Show More Authors

Roller-Compacted Concrete is a no-slump concrete, with no reinforcing steel, no forms, no finishing and wet enough to support compaction by vibratory rollers. Due to the effect of curing on properties and durability of concrete, the main purpose of this research is to study the effect of various curing methods (air curing, 7 days water curing, and permanent water curing) and porcelanite (local material used as an Internal Curing agent) with different replacement percentages of fine aggregate (volumetric replacement) on some properties of Roller-Compacted Concrete and to explore the possibility of introducing practical Roller-Compacted Concrete for road pavement with minimum requirement of curing. Specimens were sawed fro

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Conference: 4th International Conference On Innovative Studies Of Contemporary Sciences
An anatomical and chemical comparison study of Epipremnum aureum cultivated in soil and soilless
...Show More Authors

The present study took up the different ways to cultivate the species Epipremnum aureum by two habitat water and soil and comber the anatomical features of the root, stem, and leaf. The results showed amazing significant anatomical features to the ecosystem. The root and stem anatomy showing decrease in all characters that studied but the leaf anatomy showing increase of palisade, spongy tissue thickness, midrib thickness, number of vessels in the xylem also the long and width of stomata of the soilless plants than soil ones. The upper epidermis empty from the stomata for the two treatment and the stoma diffuse in the lower epidermis, the type of it paracytic type. Also the total of flavonoids in the plant that were growth in soil reached 1

... Show More
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Semiparametric Bayesian Method with Classical Method for Estimating Systems Reliability using Simulation Procedure
...Show More Authors

               In this research, the semiparametric Bayesian method is compared with the classical  method to  estimate reliability function of three  systems :  k-out of-n system, series system, and parallel system. Each system consists of three components, the first one represents the composite parametric in which failure times distributed as exponential, whereas the second and the third components are nonparametric ones in which reliability estimations depend on Kernel method using two methods to estimate bandwidth parameter h method and Kaplan-Meier method. To indicate a better method for system reliability function estimation, it has be

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
The Effect of using 940 nm Diode Laser in Comparison with Endoactivator on Radicular Dentin Permeability and Smear Layer Removal (An in Vitro Study)
...Show More Authors

Abstract: The aim of this study is to assess the effectiveness of 940 nm diode laser in comparison to Endoactivator in elimination of smear layer in terms of radicular dentin permeability and ultra-structural changes of root canal walls by SEM evaluation. Twenty-eight single-rooted extracted lower premolars were instrumented up to size X4 (protaper Next, Dentsaply) and divided into two experimental groups according to the irrigation system, G1; activated by EndoActivator and G2; activated by Diode laser 940 nm, CW mode, 1.7 W. Afterward, the roots were made externally impermeable, filled with 2%methylene blue dye, divided horizontally into three segments representing the apical, middle, and coronal thirds then examined under stereo- micr

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Jssdds
Topical 10% lactic acid solution in the treatment of pityriasis versicolor in comparison with topical 1% clotrimazol solution (single-blind, comparative and therapeutic study)
...Show More Authors

KE Sharquie, AA Noaimi, AM Oweid, JSSDDS, 2009 - Cited by 2

View Publication
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro the Effect of Canals Instrumented with Three Rotary Ni-Ti Systems on the Dislocation Resistanceo Guttafusion ® versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly i

... Show More
View Publication Preview PDF
Crossref