Preferred Language
Articles
/
0BeMX5MBVTCNdQwCfNJi
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.

Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Engineering
A Comparative Study of a Moving Bed Biofilm Reactor and Bio-shaft Technology for a Wastewater Treatment Process: A review
...Show More Authors

In addition to the primary treatment, biological treatment is used to reduce inorganic and organic components in the wastewater. The separation of biomass from treated wastewater is usually important to meet the effluent disposal requirements, so the MBBR system has been one of the most important modern technologies that use plastic tankers to transport biomass with wastewater, which works in pure biofilm, at low concentrations of suspended solids. However, biological treatment has been developed using the active sludge mixing process with MBBR. Turbo4bio was established as a sustainable and cost-effective solution for wastewater treatment plants in the early 1990s and ran on minimal sludge, and is easy to maintain. This

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
A self-balancing platform on a mobile car
...Show More Authors

<span lang="EN-US">In the last years, the self-balancing platform has become one of the most common candidates to use in many applications such as flight, biomedical fields, and industry. In this paper, the physical prototype of a proposed self-balancing platform that described the self-balancing attitude in the (X-axis, Y-axis, or biaxial) under the influence of road disturbance has been introduced. In the physical prototype, the inertial measurement unit (IMU) sensor will sense the disturbance in (X-axis, Y-axis, and biaxial). With the determined error, the corresponding electronic circuit, DC servo motors, and the Arduino software, the platform overcame the tilt angle(disturbance). Optimization of the proportional-integral-

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jun 23 2020
Journal Name
Anziam Journal
Flow from a source above a sloping base
...Show More Authors

We consider the outflow of water from the peak of a triangular ridge into a channel of finite depth. Solutions are computed for different flow rates and bottom angles. A numerical method is used to compute the flow from the source for small values of flow rate and it is found that there is a maximum flow rate beyond which steady solutions do not seem to exist. Limiting flows are computed for each geometrical configuration. One application of this work is as a model of saline water being returned to the ocean after desalination. References Craya, A. ''Theoretical research on the flow of nonhomogeneous fluids''. La Houille Blanche, (1):22–55, 1949. doi:10.1051/lhb/1949017 Dun, C. R. and Hocking, G. C. ''Withdrawal of fluid through

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Materials Science Forum
The Effect of Gamma Radiation on the Manufactured HgBa&lt;sub&gt;2&lt;/sub&gt;Ca&lt;sub&gt;2&lt;/sub&gt;Cu&lt;sub&gt;2.4&lt;/sub&gt;Ag&lt;sub&gt;0.6&lt;/sub&gt;O&lt;sub&gt;8+δ&lt;/sub&gt; Compound
...Show More Authors

In this article four samples of HgBa2Ca2Cu2.4Ag0.6O8+δ were prepared and irradiated with different doses of gamma radiation 6, 8 and 10 Mrad. The effects of gamma irradiation on structure of HgBa2Ca2Cu2.4Ag0.6O8+δ samples were characterized using X-ray diffraction. It was concluded that there effect on structure by gamma irradiation. Scherrer, crystallization, and Williamson equations were applied based on the X-ray diffraction diagram and for all gamma doses, to calculate crystal size, strain, and degree of crystallinity. I

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Int. J. Nonlinear Anal. Appl.
A topology on a ring part of is-algebra
...Show More Authors

Scopus (1)
Scopus Clarivate
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Modeling of a Sulfonation Reactor in a Detergent Factory
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Nov 06 2023
Journal Name
Eneurologicalsci
Dandy-Walker syndrome associated with a giant occipital meningocele: A case report and a literature review
...Show More Authors

HTH Ahmed Dheyaa Al-Obaidi,", Ali Tarik Abdulwahid', Mustafa Najah Al-Obaidi", Abeer Mundher Ali', eNeurologicalSci, 2023

View Publication
Scopus (2)
Scopus
Publication Date
Mon Jun 19 2017
Journal Name
Arabian Journal For Science And Engineering
A New Method to Tune a Fractional-Order PID Controller for a Twin Rotor Aerodynamic System
...Show More Authors

View Publication
Scopus (31)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2015
Journal Name
College Of Islamic Sciences
Acquisition provisions in Islamic jurisprudence: A model - a comparative study
...Show More Authors

Acquisition provisions in Islamic jurisprudence

View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
A Study of a-Si:H Absorption Edge Using Dunstan’s Model
...Show More Authors

The optical absorption data of Hydrogenated Amorphous Silicon was analyzed using a Dunstan model of optical absorption in amorphous semiconductors. This model introduces disorder into the band-band absorption through a linear exponential distribution of local energy gaps, and it accounts for both the Urbach and Tauc regions of the optical absorption edge.Compared to other models of similar bases, such as the O’Leary and Guerra models, it is simpler to understand mathematically and has a physical meaning. The optical absorption data of Jackson et al and Maurer et al were successfully interpreted using Dunstan’s model. Useful physical parameters are extracted especially the band to the band energy gap , which is the energy gap in the a

... Show More
View Publication Preview PDF
Scopus Crossref