Preferred Language
Articles
/
0BeMX5MBVTCNdQwCfNJi
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.

Publication Date
Fri Dec 01 2017
Journal Name
2017 Ieee 56th Annual Conference On Decision And Control (cdc)
Hierarchical non-singular terminal sliding mode controller for a single link flexible joint robot manipulator
...Show More Authors

—This paper studies the control motion of a single link flexible joint robot by using a hierarchical non-singular terminal sliding mode controller (HNTSMC). In comparison to the conventional sliding mode controller (CSMC), the proposed algorithm (NTSMC) not only can conserve characteristics of the convention CSMC, such as easy implementation, guaranteed stability and good robustness against system uncertainties and external disturbances, but also can ensure a faster convergence rate of the systems states to zero in a finite time and singularity free. The flexible joint robot (FJR) is a two degree of freedom (2DOF) nonlinear and underactuated system. The system here is modeled as a fourth order system by using Lagrangian method. Based on t

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Crossref
Publication Date
Tue Aug 31 2021
Journal Name
Inmateh Agricultural Engineering
DETERMINING THE EFFICIENCY OF A SMART SPRAYING ROBOT FOR CROP PROTECTION USING IMAGE PROCESSING TECHNOLOGY
...Show More Authors

A system was used to detect injuries in plant leaves by combining machine learning and the principles of image processing. A small agricultural robot was implemented for fine spraying by identifying infected leaves using image processing technology with four different forward speeds (35, 46, 63 and 80 cm/s). The results revealed that increasing the speed of the agricultural robot led to a decrease in the mount of supplements spraying and a detection percentage of infected plants. They also revealed a decrease in the percentage of supplements spraying by 46.89, 52.94, 63.07 and 76% with different forward speeds compared to the traditional method.

View Publication Preview PDF
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
An update on Nanoparticle Formulation Design of Piperine to Improve its Oral bioavailability: A Review
...Show More Authors

Piperine, a crystalline alkaloid compound isolated from Piper nigrum, piper longum, and other types of piper, has had many fabulous pharmacological advantages for preventing and treating some specific diseases, such as analgesic, anti-inflammatory, hepatoprotective, antimetastatic, antithyroid, immunomodulatory, antitumor, rheumatoid arthritis, osteoarthritis, Alzheimer's, and improving the bioavailability of other drugs. However, its potential for clinical use through oral usage is hindered by water solubility and poor bioavailability. The low level of oral bioavailability is caused by low solubility in water and is photosensitive, susceptible to isomerization by UV light, which causes piperine concentration to decrease. Many different

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Telecommunication Systems
Nature-inspired optimization algorithms for community detection in complex networks: a review and future trends
...Show More Authors

View Publication
Scopus (30)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Wed May 08 2024
Journal Name
Journal Of Mathematics And Computer Science
How does media coverage affect a COVID-19 pandemic model with direct and indirect transmission?
...Show More Authors

In this paper, a compartmental differential epidemic model of COVID-19 pandemic transmission is constructed and analyzed that accounts for the effects of media coverage. The model can be categorized into eight distinct divisions: susceptible individuals, exposed individuals, quarantine class, infected individuals, isolated class, infectious material in the environment, media coverage, and recovered individuals. The qualitative analysis of the model indicates that the disease-free equilibrium point is asymptotically stable when the basic reproduction number R0 is less than one. Conversely, the endemic equilibrium is globally asymptotically stable when R0 is bigger than one. In addition, a sensitivity analysis is conducted to determine which

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
A Spectral, Optical, Microscopic Study, Synthesis and Characterization of PVC Films Containing Schiff Base Complexes
...Show More Authors

In this work, synthesis of conducting polymeric films namely, PVC thin films was carried out containing Schiff base (L) with Cu2+, Cr3+, Ni2+, Co2+, in addition to inspecting the possibilities of measuring energy gap values of PVC-L-M with variety metal ions. These new polymeric films (PVC-L-M) were characterized by FTIR spectrophotometry, energy gap and surface morphology. The optical data recorded that the band gap values are influenced by the type of metals. All modified films have a red shift in optical properties in the ultraviolet region. The PVC-L-Co(II) was the lowest value of the optical band gap, 3.1 eV.

View Publication Preview PDF
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
International Journal On Interactive Design And Manufacturing (ijidem)
A real-time automated sorting of robotic vision system based on the interactive design approach
...Show More Authors

View Publication
Scopus (39)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
A Magnetic Field Concentration Method for Magnetic Flux Leakage Detection of Rail-Top Surface Cracks
...Show More Authors

View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Ieee Access
A Novel Approach to Improving Brain Image Classification Using Mutual Information-Accelerated Singular Value Decomposition
...Show More Authors

View Publication
Scopus (48)
Crossref (43)
Scopus Clarivate Crossref