Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.
An anal fissure which does not heal with conservative measures as sits baths and laxatives is a chronic anal fissure. Physiologically, it is the high resting tone of the internal anal sphincter that chiefly interferes with the healing process of these fissures. Until now, the gold standard treatment modality is surgery, either digital anal dilatation or lateral sphincterotomy. However, concerns have been raised about the incidence of faecal incontinence after surgery. Therefore, pharmacological means to treat chronic anal fissures have been explored.A Medline and pub med database search from 1986-2012 was conducted to perform a literature search for articles relating to the non-surgical treatment of chronic anal fissure.Pharmacological s
... Show MorePurpose/objective:
1 - To explain the financial impact of the activities and areas of human resources management and the adoption of the methodology for estimating costs on the basis of conduct and statement of how to assess costs and benefits of human resource activities.
2 - Measuring human capital, and its impact on the financial statements.
Design/methodology/approach:
Concentrated dimensions of the research paper's lack of financial statements prepared by the organizations for information mandated human resource its components of the three (attraction - development
... Show MoreSpergularia iraqensis sp. nov. is described as a new species from Iraq. This species has been collected from Diyala Province in the central east of Iraq; it is closely related to Spergularia rubra (L.) J. Presl & C. Presl, 1819 and Spergularia bocconei (Scheele) Graebn., 1919.
The distinguishing of the morphological characteristics of the new species alongside the two similar species are discussed with photographs, and an identification key is given for Spergularia iraqensis and other closely related species.
Recently times, industrial development has increased, including plastic industries, and since plastic has a very long analytical life, it will cause environmental pollution. Therefore studies have resorted to reusing recycled plastic waste (sustainable plastic) to produce environmentally friendly concrete (green concrete). In this research, some studies were reviewed and then summarized into several things, including the percentage of plastic replacement from the aggregate and the effect of this percentage on the fresh properties of concrete, such as the workability and the effect of plastic waste on the hardening properties of concrete such as dry density, compressive, tensile and flexural strength.