A Comparative Study of Pediatric Fracture Shaft Femur Fixating by Plate and Screws Using Lateral Approach Between Subvastus Lateralis and Transvastus Lateralis Outcome
...Show More Authors

BACKGROUND: Femoral shaft fracture is a common fracture in pediatric age group reaching 62% of all fracture shaft femur in children in spite of rapid union rate and successful conservative treatment but some cases need surgical intervention and one of the methods using plate and screw by the lateral approach. AIM: This study aims to compare functional outcome fixation of mid-shaft femur fracture in children by plate and screws between (subvastus lateralis and transvastus lateralis) regarding infection, union, and limitation of knee movement. PATIENT AND METHOD: The study was done on 30 children who had diaphyseal fracture femur in Al-Kindy Teaching Hospital in period (April 2018–April 2020) with 6 months follow-up, and the patient was divided into two groups: Group A first treated by subvastus lateral approach 15 patients and the second group, Group B by transvastus lateral approach 15 patients and follow-up done for them after 2 weeks, 4 weeks, 6 weeks, 3 months, and 6 months. RESULTS: At week 16 of follow-up all patients in Group A had union, while in Group B, 14 of 50 patients had union and one patient had no union and one patient in Group B had an infection when compared to Group A. From 15 patients of Group A, two patients had limitation of knee movement in the 1st month of follow-up then in the 3rd month of follow-up, no patient had limitation of knee joint movement, while five patients had limitation of knee joint movement in Group B in the 1st month of follow-up and one patient had limitation knee joint movement in the 3rd month of follow-up. CONCLUSIONS: The subvastus lateralis approach results better than transvastus lateralis in union.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
A comparative study between conventional methods and Vidas UP Salmonella (SPT) to investigate salmonella species from local and imported meat
...Show More Authors

The study was preformed for investigating of Salmonella from meat, and compared Vidas UP Salmonella (SPT) with the traditional methods of isolation for Salmonella , were examined 42 meat samples (Beef and Chicken) from the Local and Imported From local markets in the city of Baghdad from period December 2013 -February 2014 the samples were cultured on enrichment and differential media and examined samples Vidas, and confirmed of isolates by cultivation chromgenic agar, biochemical tests ,Api20 E systeme , In addition serological tests , and the serotypes determinate in the Central Public Health Laboratory / National Institute of Salmonella The results showed the contamination in imported meat was more than in the local meat 11.9% and 2

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 28 2019
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Kinetic profile of silver and zinc oxide nanoparticles by intraperitoneal injection in mice , a comparative study
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Sun Jan 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu May 12 2011
Journal Name
Iraqi Journal Of Medical Science
A comparative study between the side effects of copper intrauterine device in women with non-scarred and scarred uterus
...Show More Authors

Publication Date
Thu Aug 01 2024
Journal Name
Advances In Science And Technology Research Journal
Power Predicting for Power Take-Off Shaft of a Disc Maize Silage Harvester Using Machine Learning
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Nov 26 2017
Journal Name
Journal Of Engineering
Numerical Study of Heat Transfer Enhancement for a Flat Plate Solar Collector by Adding Metal Foam Blocks
...Show More Authors

Numerical study has been conducted to investigate the thermal performance enhancement of flat plate solar water collector by integrating the solar collector with metal foam blocks.The flow is assumed to be steady, incompressible and two dimensional in an inclined channel. The channel is provided with eight foam blocks manufactured form copper. The Brinkman-Forchheimer extended Darcy model is utilized to simulate the flow in the porous medium and the Navier-Stokes equation in the fluid region. The energy equation is used with local thermal equilibrium (LTE) assumption to simulate the thermofield inside the porous medium. The current investigation covers a range of solar radiation intensity at 09:00 AM, 12:00 PM, and 04:00

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL AND NUMERICAL STRESS ANALYSIS OF INVOLUTE SPLINED SHAFT
...Show More Authors

In this study, the induced splined shaft teeth contact and bending stresses have been investigated numerically using finite element method(Ansys package version 11.0) with changing the most effecting design parameter,(pressure angle, teeth number, fillet radius and normal module), for internal and external splined shaft. Experimental work has been achieved using two dimensional photoelastic techniques to get the contact and bending stresses; the used material is Bakelite sheet type “PSM-4”.
The results of numerical stress analysis indicate that, the increasing of the pressure angle and fillet radius decrease the bending stress and increase the contact stress for both internal and external spline shaft teeth while the increasing of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
A comparative Isothermal and Kinetic Study of the Adsorption of Lead (II) from Solution by Activated Carbon and Bentonite
...Show More Authors

This work is aiming to study and compare the removal of lead (II) from simulated wastewater by activated carbon and bentonite as adsorbents with particle size of 0.32-0.5 mm. A mathematical model was applied to describe the mass transfer kinetic.

The batch experiments were carried out to determine the adsorption isotherm constants for each adsorbent, and five isotherm models were tested to choose the best fit model for the experimental data. The pore, surface diffusion coefficients and mass transfer coefficient were found by fitting the experimental data to a theoretical model. Partial differential equations were used to describe the adsorption in the bulk and solid phases. These equations were simplified and the

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 02 2012
Journal Name
Journal Of The Faculty Of Medical Baghdad
Comparative study between ultrasound findings and intra-operative in non-traumatic abdominal pain
...Show More Authors

Publication Date
Sun Oct 02 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparative study between Harmonic FOCUSTM to clamp and tie technique for total thyroidectomy
...Show More Authors

Background: Thyroid surgery has undergone many changes during the past 2 decades, including the introduction of new surgical techniques such as endoscopic or video-assisted approaches, anesthesia care, intraoperative nerve monitoring and new hemostatic tools
Objectives: to assess the efficacy and safety of Harmonic Focus shears in total thyroidectomy compared with conventional surgical technique.
Patients and methods: prospective study conducted from October 2011 till January 2016, two handers and nine patients with benign and malignant thyroid diseases, scheduled for total thyroidectomy in a governor and private hospitals were enrolled randomly into 2 groups, group A consists of 105 patient who undergone a total thyroidectomy usin

... Show More
View Publication Preview PDF
Crossref