Preferred Language
Articles
/
-xg3KJUBVTCNdQwC1Sj9
Electrochemical harvesting of Chlorella sp.: Electrolyte concentration and interelectrode distance
...Show More Authors

Two modes of electrochemical harvesting for microalgae were investigated in the current work. A sacrificial anode (aluminum) was used to study the electrocoagulation-flotation process, and a nonsacrificial anode (graphite) was used to investigate the electroflotation process. The study inspected the effect of chloride ions concentration and the interelectrode distance on the performance of the electrochemical harvesting processes. The results demonstrated that both electrodes achieved maximum harvesting efficiency with a 2 g/L NaCl concentration. Interestingly, by increasing the NaCl concentration to 5 g/L, the harvesting efficiency reduced dramatically to its lowest value. Generally, the energy consumption decreased with increasing of NaCl concentration. Moreover, the energy consumption achieved with aluminum anodes is lower than that achieved with graphite. However, by increasing the gap between the electrodes from 15 mm to 30 mm, the time required to achieve the maximum efficiency doubled, and energy consumption increased consequently.

View Publication
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
Stress Concentration factor Analysis of Helical Gear Drives with Asymmetric Teeth Profiles
...Show More Authors

This study investigates the influence of asymmetric involute teeth profiles for helical gears on the bending stress. Theoretically, bending stress has been estimated in spur involute gears which have symmetric teeth profile by based on the Lewis, 1892 equation. Later, this equation is developed by, Abdullah, 2012. to determine the effect of an asymmetric tooth profile for the spur gear on the bending stress. And then these equations are applied with stress concentration factor once for symmetric and once other for asymmetric teeth profile. In this paper, the bending stresses for various types of helical gear with various types of asymmetric teeth profile are calculated numerically for defined the stress concentration fac

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Science
Electrochemical Polymerization and Biological Activity of 4-(Nicotinamido)-4-Oxo-2-Butenoic Acid as An Anticorrosion Coating on A 316L Stainless Steel Surface
...Show More Authors

In this study, poly4-(nicotinamido)-4-oxo-2-butenoic acid (PNOE) was prepared by the electro polymerization of 4-(nicotinamido)-4-oxo-2-butenoic acid (NOE) monomer on a 316 stainless steel (St.St) which acts as an anticorrosion coating.  Fourier transforms infrared (FTIR), atomic force microscopy (AFM), scanning electron microscopy (SEM), and cyclic voltammetry were used to diagnose the structure and the properties of the prepared polymer layer. The corrosion behavior of the uncoated and coated 316  St.St were evaluated by using an electro chemical polarization technique in 0.2 M hydrochloric acid  solution as a corrosive medium at a temperature range of 293 to 323 K. Nano materials, such as nano ZnO and graphene were adde

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Radiological Risk Assessment and Radioactivity Concentration in sediment of Tigris River of the Medical City/Bab Al Muadham
...Show More Authors

The concentrations of natural radionuclides in sediment samples from various locations along the stream of the Tigris riverbank in the Medical city in Bab Al- Muadham, Baghdad, had been examined using NaI(Tl) detector. The mean concentrations of specific activity for 238U, 232Th, 40K and 137Cs for sediments of the river was 13.5±4.6, 35.2±3.1, 272.2±21.4 and 1.5±0.35 Bq/kg  respectively. The findings revealed  that the concentration values of natural radionuclides and cesium were below permitted limits. The radiological hazard was compared with a global average (Radium equivalent, absorbed dose rate, radiation hazard index and annual effective dose equivalent) finding it was less

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More
Publication Date
Mon Jan 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Assessment of Long Distance Chasing Photometer (NAG-ADF-300-2) by Estimating the Drug Atenolol with Povidone Iodine Via CFIA
...Show More Authors

     Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200 µL respectively to cell A and cell  B. Correlation coefficient (r) 0.9957 for cell A and 0.9974 for cell. Relative standard deviation (RSD %) was lower than 1%, (n=8) for the determination of

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Iraqi Journal Of Oil And Gas Research (ijogr)
Comparative study of electrochemical oxidation system hybrid with photocatalytic system for the treatment of Al-Najaf petroleum refinery wastewater
...Show More Authors

View Publication
Crossref
Publication Date
Tue Feb 19 2019
Journal Name
Heat And Mass Transfer
Mass transfer characteristics of a flow-by fixed bed electrochemical reactor composed of vertical stack stainless steel screens cathode
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
The Effect of Chlorine Concentration on the Optical Constants of SnS Thin Films
...Show More Authors

Chlorine doped SnS have been prepared utilizing chemical spray pyrolysis. The effects of chlorine concentration on the optical constants were studied. It was seen that the transmittance decreased with doping, while reflectance, refractive index, extinction coefficient, real and imaginary parts of dielectric constant were increased as the doping percentage increased. The results show also that the skin depth decrease as the chlorine percentage increased which could be assure that it is transmittance related.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
The Effect of the Concentration of Colloidal Silver Nanoparticles on Optical Limiting Reliability
...Show More Authors

The effect of the concentration of the colloidal nanomaterial on their optical limiting behavior is reported in this paper. The colloids of sliver nanoparticles in deionized water were chemically prepared for the two concentrations (31 ppm and 11ppm). Two cw lasers (473 nm Blue DPSS laser and 532 nm Nd:YAG laser) are used to compare the optical limiting performance for the samples. UV–visible spectrophotometer, transmission electron microscope (TEM) and Fourier Transformation Infrared Spectrometer (FTIR) were used to obtain the characteristics of the sample. The nonlinear refractive index was calculated to be in the order of 10-9 cm2/W. The results demonstrate that the observed limiting response is significant for 532nm. In addition, t

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Effect of Subinhibitory concentration of Antibiotic on Bacterial Adherence to Orthopedic Prosthetic Device
...Show More Authors

The effect of subinhibitory concentration of Antibiotics on the Adherence of S.aureus (Coagulase Positive Staphylococci), and S.epidermidis (Coagulase negative Staphylococci) and Pseudomonas aeruginosa, Enterobacter cloacae, Citobacter freundi (Gram negative bacteria) was done and the results revealed that Rifampicin was the best antibiotic inhibiting Staphylococci adherence and Vancomycin has less effect on the adherence of Staphylococci, whereas Tetracyclin was the best antibiotic inhbiting Gram negative bacteria adherence and Amikacin has the lest less effect on inhibiting bacterial adherence.

View Publication Preview PDF