Preferred Language
Articles
/
-xdNso4BVTCNdQwC9Va1
Continuous Flow Injection Analysis,Turbidmetric and Photometric Determination of Methyldopa Using a New Long Distance Chasing Photometer (NAG-ADF-300-2)
...Show More Authors

A specific, sensitive and new simple method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation of ion pair compound between methyldopa and potassium hexacyanoferrate in acidic medium to obtain a yellow precipitate complex using long distance chasing photometer (NAG-ADF-300-2). The linear range for calibration graph was 0.05-35 mmol/L for cell A and 0.05-25 mmol/L for cell B, and LOD 1.4292 µg /200 µL for both cells with correlation coefficient (r) 0.9981 for cell A and 0.9994 for cell B, RSD% was lower than 0.5 % for n=8 for. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbidmetric method by using the standard addition method via the use of t-test, at 95% confidence level. The comparison of data explain that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection and wide application.

Scopus Crossref
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
FLOW INJECTION ANALYSIS AND SPECTROPHOTOMETRIC DETERMINATION OF NIFEDIPINEIN PHARMACEUTICAL FORMULATION: FLOW INJECTION ANALYSIS AND SPECTROPHOTOMETRIC DETERMINATION OF NIFEDIPINEIN PHARMACEUTICAL FORMULATION
...Show More Authors

A new simple and sensitive spectrophotometric method is described for quantification of Nifedipine (NIF) and their pharmaceutical formulation. The selective method was performed by the reduction of NIF nitro group to yield primary amino group using zinc powder with hydrochloric acid. The produced aromatic amine was submitted to oxidative coupling reaction with pyrocatechol and ammonium ceric nitrate to form orange color product measured spectrophotometrically with maximum absorption at 467nm. The product was determined through flow injection analysis (FIA) system and all the chemical and physical parameters were optimized. The concentration range from 5.0 to 140.0 μg.mL-1 was obeyed Beer’s law with a limit of detection and quantitatio

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 19 2022
Journal Name
Chemistryselect
A Continuous Flow Injection/Indirect Photometric Method for the Detection of Fosetyl Aluminum in Commercial Pesticide Formulations
...Show More Authors
Abstract<p>Because of their Physico‐chemical characteristics and its composition, the development of new specific analytical methodologies to determine some highly polar pesticides are required. The reported methods demand long analysis time, expensive instruments and prior extraction of pesticide for detection. The current work presents a new flow injection analysis method combined with indirect photometric detection for the determination of Fosetyl‐Aluminum (Fosetyl‐Al) in commercial formulations, with rapid and highly accurate determination involving only construction of manifold system combined with photometric detector without need some of the pre‐treatments to the sample before the analysis such a</p> ... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (4)
Scopus Crossref
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Wed Jun 01 2022
Journal Name
Analytical Methods In Environmental Chemistry Journal
Design a continuous microfluidic flow cell for turbidimetric-flow injection technology: A new approach for routine analysis of active pharmaceutical formulations
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Thymol Using Procaine Hydrochloride as a New Chromogenic Reagent
...Show More Authors

New, simple and sensitive batch and Flow-injecton spectrophotometric methods for the determination of Thymol in pure form and in mouth wash preparations have been proposed in this study. These methods were based on a diazotization and coupling reaction between Thymol and diazotized procaine HCl in alkaline medium to form an intense orange-red water-soluble dye that is stable and has a maximum absorption at 474 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 0.4-4.8 and 4-80 µg.ml-1 of Thymol, with detection limits of 0.072 and 1.807 µg.ml-1 of Thymol for batch and FIA methods respectively. The FIA procedure sample throughput was 80 h-1. All different chemical and physical e

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0–180° Using a Single Solar Cell as a Detector
...Show More Authors

A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection o

... Show More
Scopus (10)
Crossref (4)
Scopus Crossref
Publication Date
Tue Jun 17 2025
Journal Name
Baghdad Science Journal
Utilizing an Atomic Force Microscopy with Continuous Flow Injection Analysis using NAG-4(sources)x3 with Three Solar Cells (NAG-4SX3-3D) Analyzer for Studying the Surface Morphology of the Precipitate of the Cyproheptadine-HCl and Loratadine
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric and Reverse Flow Injection Method Determination of Nitrazepam in Pharmaceuticals Using O-Coumaric Acid as a New Chromogenic Reagent
...Show More Authors

            A spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the   determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (1)
Scopus Clarivate Crossref