Heart failure (HF) is characterized by family history and clinical examination combined with diagnostic tools such as electrocardiogram, chest x-ray and an assessment of left ventricular function by echocardiography. An early diagnosis of heart failure is still based on symptoms of dyspnea, fatigue and signs of fluid overload. Serum N-terminal pro-B-type natriuretic peptide (NT-pro BNP) is cardiac biomarker has emerged as potential predictor of heart failure. It is used as a sensitive biomarker in diagnosis and assessment severity of heart failure. This study assed the diagnostic value of (NT-pro BNP), in Iraqi children patients with heart failure and its correlation with LVEF% especially in emergency rooms of hospitals.Ninety (90) consecutive children with HF were enrolled in this study due to dilated cardiomyopathy (DCM) and (30) healthy controls. The levels of serum (NT-pro BNP) were measured, echocardiography was performed for all patients and left ventricle ejection fraction (LVEF) was calculated. The results of present study significant high mean value (± SD) of (NT-pro BNP) were recorded in serum of children with HF when compared with control group (p = 0.0001) and significant negative correlation was noticed between (NT pro-BNP) levels and left ventricular ejection fraction (r = -0.902, p = 0.0001). NT- pro-BNP appears to play a powerful role as a diagnostic and prognostic biomarker for children with heart failure and associated directly with the severity of HF in children with heart failure due to dilated cardiomyopathy (DCM
Abstract
The purpose of our study was to develop Dabigatran Etexilate loaded nanostructured lipid carriers (DE-NLCs) using Glyceryl monostearate and Oleic acid as lipid matrix, and to estimate the potential of the developed delivery system to improve oral absorption of low bioavailability drug, different Oleic acid ratios effect on particle size, zeta potential, entrapment efficiency and loading capacity were studied, the optimized DE-NLCs shows a particle size within the nanorange, the zeta potential (ZP) was 33.81±0.73mV with drug entrapment efficiency (EE%) of 92.42±2.31% and a loading capacity (DL%) of 7.69±0.17%. about 92% of drug was released in 24hr in a controlled manner, the ex-vivo intestinal p
... Show MoreThis study aims to determine the reasons for the increase in the frequency of sand and dust storms in the Middle East and to identify their sources and mitigate them. A set of climatic data from 60 years (1960–2022) was analyzed. Sand storms in Iraq are a silty sand mature arkose composed of 72.7% sand, 25.1% silt, and 2.19% clay; the clay fraction in dust storms constitutes 70%, with a small amount of silt (20.6%) and sand (9.4%). Dust and sand storms (%) are composed of quartz (49.2, 67.1), feldspar (4.9, 20.9), calcite (38, 5), gypsum (4.8, 0.4), dolomite (0.8, 1.0), and heavy minerals (3.2, 6.6). Increasing temperatures in Iraq, by an average of 2 °C for sixty years, have contributed to an increase in the number of dust storm
... Show MoreThe combined system of electrocoagulation (EC) and electro-oxidation (EO) is one of the most promising methods in dye removal. In this work, a solution of 200 mg/l of Congo red was used to examine the removal of anionic dye using an EC-EO system with three stainless steel electrodes as the auxiliary electrodes and an aluminum electrode as anode for the EC process, Cu-Mn-Ni Nanocomposite as anode for the EO process. This composite oxide was simultaneously synthesized by anodic and cathodic deposition of Cu (NO3)2, MnCl2, and Ni (NO3)2 salts with 0.075 M as concentrations of each salt with a fixed molar ratio (1:1:1) at a constant current density of 25 mA/cm2. The characteristics structure and surface morphology of the depo
... Show MoreThis study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u
... Show MoreCompounds of (ZnO)1-x(SnO 2 ) x were prepared with various proportions of tin oxide (SiO 2) (x = 0.0, 0.2, 0.4, 0.6, 0.8, 1.0) by mixing zinc oxide (ZnO) with highpurity tin oxide and then sintering the mixture in an oven at a temperature of 1000 °C for a period of 1 h. The resulting powders were ground and pressed into tablets of 1 cm diameter and 0.5 cm thickness. The properties of (ZnO) 1-x(SnO 2 ) x composites flms were prepared and studied as sensitive to the diferent gases NO2 and H2 S. Thin flms were prepared from (ZnO) 1-x(SnO 2 ) x via pulsed laser deposition method using glass and single crystal silicon for investigation the morphology and gas sensing properties with a thickness of 150 nm. The morphology examinat
... Show MoreThe Iraqi pharmaceutical sector faces significant challenges arising from the prevalence of substandard and falsified (S/F) medications, which pose a direct threat to public health safety. To strengthen regulatory oversight, health authorities have implemented national medicine track-and-trace system. However, the ultimate efficacy of these regulatory tools is heavily dependent on public awareness and the level of societal acceptance.
This study ai