Preferred Language
Articles
/
-hceVo4BVTCNdQwCaUKv
Absorption Wavebands for Discriminating Oxidation Time of Engine Oil as Detected by FT-IR Spectroscopy
...Show More Authors

Fourier Transform-Infrared (FT-IR) spectroscopy was used to analyze gasoline engine oil (SAE 5W20) samples that were exposed to seven different oxidation times (0 h, 24 h, 48 h, 72 h, 96 h, 120 h, and 144 h) to determine the best wavenumbers and wavenumber ranges for the discrimination of the oxidation times. The thermal oxidation process generated oil samples with varying total base number (TBN) levels. Each wavenumber (400–3900 cm−1) and wavenumber ranges identified from the literature and this study were statistically analyzed to determine which wavenumbers and wavenumber ranges could discriminate among all oxidation times. Linear regression was used with the best wavenumbers and wavenumber ranges to predict oxidation time.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Statistical Mean Studying for Detected Intensities by Enet Web Camera for the White Test Image Under Different Fluorescent Lightness
...Show More Authors

    The aim of this work, is to study color filming by using different intensities of fluorescent light, where we evaluate the capture image qualities for the RGB bands and component of L. And we study the relation between the means of RGBL values of the images as a function of the power of fluorescent light circuit . From the results, we show that the mean μ increases rapidly at low power values, then it will reach the stability at high power values.  

View Publication Preview PDF
Publication Date
Sat Mar 20 2021
Journal Name
Neuroquantology
XRD and Microscopic Images for Synthesis Graphite Nanoparticles by Oxidation Method
...Show More Authors

Graphite nanoparticles were successfully synthesized using mixture of H2O2/NH4OH with three steps of oxidation. The process of oxidations were analysis by XRD and optics microscopic images which shows clear change in particle size of graphite after every steps of oxidation. The method depend on treatments the graphite with H2O2 in two steps than complete the last steps by reacting with H2O2/NH4OH with equal quantities. The process did not reduces the several sheets for graphite but dispersion the aggregates of multi-sheets carbon when removed the Van Der Waals forces through the oxidation process.

View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Silver Nanoflowers as an Interfacial Liquid-State Surface Enhanced Raman Spectroscopy (SERS) Sensor for Water Pollution
...Show More Authors

Water pollution has created a critical threat to the environment.‎‎ A lot of research has been done ‎recently to use surface-enhanced Raman spectroscopy (SERS) to detect multiple pollutants in water. This study aims to use Ag colloid nanoflowers as liquid SERS enhancer. Tri sodium phosphate (Na3PO4) was investigated as a pollutant using liquid SERS ‎based on colloidal Ag ‎nanoflowers. The chemical method was used to synthesize nanoflowers from silver ‎ions. Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM), and X-ray diffractometer (XRD) were employed to characterize the silver nanoflowers. This ‎nanoflowers SERS action in detecting Na3PO4 was reported and analyzed

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oxidation of Phenolic Wastewater by Fenton's Reagent
...Show More Authors

Phenol oxidation by Fenton's reagent (H2O2 + Fe+2) in aqueous solution has been studied for the purpose of learning
more about the reactions involved and the extent of the oxidation process, under various operating conditions. An initial
phenol concentration of 100 mg/L was used as representative of a phenolic industrial wastewater. Working temperature
of 25C was tested, and initial pH was set at 5.6 . The H2O2 and the Fe+2 doses were varied in the range of
(H2O2/Fe+2/phenol = 3/0.25/1 to 5/0.5/1). Keeping the stirring speed of 200 rpm.
The results exhibit that the highest phenol conversion (100%) was obtained under (H2O/Fe+2/phenol ratio of 5/0.5/1)
at about 180 min. The study has indicated that Fenton's oxidation i

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Corrosion Parameters for a Cathodic Reaction Complicated by IR Drop Effect in a Flow System
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Feb 15 2021
Journal Name
Systematic Review In Pharmacy
Colorimetric Determination Of Sitagliptin As An Oxidation Derivative Of Ninhydrin
...Show More Authors

A sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and

... Show More
Preview PDF
Publication Date
Thu Apr 12 2018
Journal Name
Lubricants
Importance of Emulsification in Calibrating Infrared Spectroscopes for Analyzing Water Contamination in Used or In-Service Engine Oil
...Show More Authors

View Publication
Scopus (14)
Crossref (10)
Scopus Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Desulfurization of Diesel Fuel by Oxidation and Solvent Extraction
...Show More Authors

This research presents a study in ultra-desulfurization of diesel fuel produced from conventional hydro desulfurization process, using oxidation and solvent extraction techniques. Dibenzothiophene (DBT) was the organosulfur compound that had been detected in sulfur removal. The oxidation process used hydrogen peroxide as an oxidant and acetic acid as homogeneous catalyst . The solvent extraction process used acetonitrile (ACN) and N-methyl – 2 - pyrrolidone (NMP) as  extractants . Also the effect of five parameters (stirring speed :150 , 250 , 350 , and 450) rpm, temperature (30 , 40 , 45 , and 50) oC, oxidant/simulated diesel fuel ratio (0.5 , 0.75 , 1 , and 1.5) , catalyst/oxidant ratio(0.125,0.25,0.5

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Generation of 16 Micrometer IR Laser by theOptical Pumping of CF4 Gas Molecules
...Show More Authors

We report here the observation of 16 µm superradiance laser action generated from optical pumping of CF4 gas molecules (which is cooled to 140 Kº by a boil-off liquid-N2) by a TEA-CO2 laser 9R12 line. Output laser pulses of 7 mJ and 200 ns have been obtained.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF