Preferred Language
Articles
/
-hbnNooBVTCNdQwCRJFZ
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by many organizations such as the United Nations scientific committee on the effects of atomic radiation (UNSCEAR), the international atomic energy agency (IAEA), the world health organization (WHO), and others.

Scopus Crossref
View Publication
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography & Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (8)
Scopus Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection o

... Show More
Scopus (14)
Crossref (8)
Scopus Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Determination of Sulfacetamide Sodium in Pure and Their Pharmaceutical Formulations by Using Cloud Point Extraction Method
...Show More Authors

      In this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media.  The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w

... Show More
View Publication Preview PDF
Scopus (9)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
Effect of different concentrations of bovine serum albumin on some of the frozen sperm characteristics of the rams
...Show More Authors

This study was conducted in the Faculty of Agricultural Engineering Sciences - University of Baghdad in the field of sheep and goats in the Department of Animal Production. Effect of different concentrations of bovine albumin on some semen characteristics of frozen rams. Used in this experiment, 3 rams and their ages ranging from 2.5-3 years. The sample of the semen was diluted with Tris dilution with the addition of 10 ml of egg yolk per 100 ml, the sample by 1:1 with the tris and then the collection of sperm samples (Pooling) after the semen was divided into four treatments Control and bovine albumin at concentrations of 5, 7.5 and 10% and then complete dilution 10: 1, at 5C, dilution 20: 1, containing 5% glycerol per 100 ml. The results

... Show More
View Publication
Scopus (2)
Scopus
Publication Date
Tue Jul 04 2023
Journal Name
Qalaai Zanist Scientific Journal
The Role of The Environmental Observer and The Environmental Police in Protecting the Environment in Iraqi Law
...Show More Authors

View Publication
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
Scopus (23)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (23)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Agricultural Mechanization In Asia, Africa And Latin America
Determination of the suitability period of S-3 diesel oil when used in tractor engines
...Show More Authors

The diesel oil type S-3 specified for diesel engine has limited the suitability for diesel trucks for 8000 km, but didn't clarify its suitability if used in tractor engines.It is known that the work style of farm tractor differs from that of other vehicles where tractors are used for all the activities in sever conditions and under the complete usage of the available power and capability, so there is no sign or indication of the usage period of this oil in tractor's engine. The oil has been used on Cirta C6806 tractors. The manual book of the tractor's engine, Deutz recommends changing the oil every 100 hrs. Therefore the main goal of this research is to give the recommended working hours for S-3 diesel oil when used in farm tractor engines

... Show More
View Publication
Scopus (2)
Scopus
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Determination Of Micro Amount Of Spironolactone In Some Of Pharmaceutical Preparate By Using a Molecular Luminescence Technique.
...Show More Authors

The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods

... Show More
View Publication Preview PDF
Crossref