Objective: To determine the functional and radiological outcomes of lower third tibia closed fractures fixed by nail or plate osteosynthesis. Methodology: This randomized controlled trial included 20 patients presenting with closed fracture lower third tibia in Al-Kindy teaching hospital, Baghdad, Iraq. The patients were divided as every other one into two equal groups; group I had fractures fixed by 3.5 mm locked plate and group II by intramedullary locking nail. We followed all patients for 24 weeks to assess surgical complications, fracture union, alignment and functional outcome based on Knee society score (KSS). Results: The mean union time in both groups was 10.2 ± 1.48 and 9.3 ± 1.77 weeks, respectively (p = 0.003). Mean KSS in both groups has no significant difference (p = 0.002). Mean union time in females in the group I was higher than that of males with a significant difference (p = 0.045). In contrast, the mean KSS in males was significantly different (p = 0.017) than females. The age of the patients correlated with union time in both groups. Conclusion: Both methods are good option for fixing distal lower tibia fracture regarding the union time. No significant difference was noted in both groups in the functional outcome. Female fixed by plating may have a delay in union time and lower functional score than male
In this time, most researchers toward about preparation of compounds according to green chemistry. This research describes the preparation of 2-fluoro-5-(substituted benzylideneamino) benzonitrile under reflux and microwave methods. Six azomethine compounds (B1-6) were synthesized by two methods under reflux and assisted microwave with the comparison between the two methods. Reflux method was prepared of azomethine (B1-6) by reaction of 5-amino-2-fluorobenzonitrile with some aldehyde derivatives with (50–100) mL of absolute ethanol and some quantity of GAA and time is limited between (2–5) hours with a yield between (60–70) percent with recrystallization for appropriate solvents. But the microwave-assisted method was synthesized of co
... Show MoreBackground: Selenium-73 with half- life of 7.15 hour emits β+ in nature and has six stable isotopes which are ( 74Se,76Se,77Se,78Se,80Se and 82Se ). Selenium-73 has many applications in technology and radioselenium compounds of metallic have found various applications in medicine. Objective: To make a comparison between different reactions that produced cross sections of Se-73 radioisotopes. Subjects and methods: The feasibility of the production of Selenium -73 via various nuclear reactions was investigated. Excitation functions of 73Se production by the reactions of 75As (p,3n), 169Tm( d,x), 74Se, natSe, natBr (p,x) , 75As (d,4n), natGe (3He,x), 70Ge (α, n), and 72Ge (α, 3n) and neutron capture were calculated using the avail
... Show MoreBackground: Selenium-73 with half- life of 7.15 hour emits β+ in nature and has six stable isotopes which are ( 74Se,76Se,77Se,78Se,80Se and 82Se ). Selenium-73 has many applications in technology and radioselenium compounds of metallic have found various applications in medicine.
Objective: To make a comparison between different reactions that produced cross sections of Se-73 radioisotopes.
Subjects and methods: The feasibility of the production of Selenium -73 via various nuclear reactions was investigated. Excitation functions of 73Se production by the re
... Show Moreالوصف In this time, most researchers toward about preparation of compounds according to green chemistry. This research describes the preparation of 2-fluoro-5-(substituted benzylideneamino) benzonitrile under reflux and microwave methods. Six azomethine compounds (B1-6) were synthesized by two methods under reflux and assisted microwave with the comparison between the two methods. Reflux method was prepared of azomethine (B1-6) by reaction of 5-amino-2-fluorobenzonitrile with some aldehyde derivatives with (50–100) mL of absolute ethanol and some quantity of GAA and time is limited between (2–5) hours with a yield between (60–70) percent with recrystallization for appropriate solvents. But the microwave-assisted method was synthe
... Show MoreIn this paper the oscillation criterion was investigated for all solutions of the third-order half linear neutral differential equations. Some necessary and sufficient conditions are established for every solution of (a(t)[(x(t)±p(t)x(?(t) ) )^'' ]^? )^'+q(t) x^? (?(t) )=0, t?t_0, to be oscillatory. Examples are given to illustrate our main results.
Background: Fractures of the humeral shaft accounting for approximately 3% of all fractures. There is a wide array of good options for their treatment and controversy over the best methods. Although good techniques of osteosynthesis are available, the aim of this article is toemphasize on the benefit and good outcome of conservative treatment for properly selected cases to decrease the cost and avoid the complications of surgery. Method : During the period from February 2011 to June 2012 fifty-five fractures of humeral shaft were treated at orthopedicdepartment in the ALKindyteaching hospital. 22 fractures considered suitable for the study. The patients treatedconservatively by using the‘U’ shaped coaptation slab. Then we shift to POP c
... Show MoreBackground: Fractures of the humeral shaft
accounting for approximately 3% of all
fractures. There is a wide array of good
options for their treatment and controversy
over the best methods. Although good
techniques of osteosynthesis are available, the
aim of this article is toemphasize on the benefit
and good outcome of conservative treatment
for properly selected cases to decrease the cost
and avoid the complications of surgery.