The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in determination of trace elements levels in blood sera of asthmatic patients and the effect of these elements in pathogenesis and treatment of the disease.
In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show MoreBackground: Preeclampsia (PE) is a major cause of maternal morbidity and mortality, complicating 3-14% of all pregnancies. Although the etiology remains unknown, placental hypoperfusion and diffuse endothelial cell injury are considered to be the central pathological process; many endocrinological changes have been linked to the etiology of preeclampsia including parathyroid hormone and calcium level. Objective: to compare serum parathyroid hormone and total serum calcium levels in mild and severe preeclampsia versus normal pregnancy. Patients and methods: Serum parathyroid hormone (PTH) level and total serum calcium level were measured in thirty normotensive pregnant women and thirty women with mild preeclampsia and thi
... Show MoreThree types of medical commercial creams Silvazine, Cinolon Tar and Hydroquinon Domina were incorporated in this study. The medical creams were taken directly and placed uniformly on the glass slide. Each type of pharmaceutical was weighed at 1 mg and dispersed on an area of 1x1 cm. This process ensures same thickness for all samples. The creams were analyzed by using double-beam UV/visible spectrophotometer Metertech SP8001. The absorption spectrum for each of samples was measured against wavelength range of 300–700 nm.
Concentrations of P137PCs were measured in 40 samples that have been selected from the surface soil in cities of Ramadi, Fallujah, Heet and surrounding areas. The activity of P137PCs in seven dust storms that hit the area western of city of Ramadi within the period 1/3/2013-1/10/2013 was measured also. The concentration in soil ranges between (below detection level-14.5) Bq.kgP-1P, while it ranges between (7.5-8.8) Bq/kg in the dust storms. The dose due to exposure to the cesium in surface soil was estimated to be ranged between (0.4-7.7) *10P-2P mSv.yP-1P while the effective doses due to inhalation of resuspended P137PCs was about 1.61*10P-8P and the doses caused by inhalation of P137PCs in dust storms is ranging between (8.13-9.54)*10P
... Show MoreZinc Oxide (ZnO) is probably the most typical II-VI
semiconductor, which exhibits a wide range of nanostructures. In
this paper, polycrystalline ZnO thin films were prepared by chemical
spray pyrolysis technique, the films were deposited onto glass
substrate at 400 °C by using aqueous zinc chloride as a spray
solution of molar concentration of 0.1 M/L.
The crystallographic structure of the prepared film was analyzed
using X-ray diffraction; the result shows that the film was
polycrystalline, the grain size which was calculated at (002) was
27.9 nm. The Hall measurement of the film studied from the
electrical measurements show that the film was n-type. The optical
properties of the film were studied using
Scattering and Absorption Efficiencies of Si-Ag Coaxial nanowire (NWs) were simulated using Mie-Lorentz scattering approach. The thickness of Ag shell was fixed at around 10 nm with Si core diameter of (10, 20, 30 and 40) nm. Scattering Efficiencies and Absorption Efficiencies of core-shell nanowire as a function of wavelength (300-2000 nm) within various core diameters were calculated. The study shows a remarkable behavior of scattering for un-polarized light in Silicon nanowire (core only) with wavelength of (320- 500nm). In other words, adding Ag shell has decreased the scattering efficiency of core-shell nanowire for all diameters.
The cathodic deposition of zinc from simulated chloride wastewater was used to characterize the mass transport properties of a flow-by fixed bed electrochemical reactor composed of vertical stack of stainless steel nets, operated in batch-recycle mode. The electrochemical reactor employed potential value in such a way that the zinc reduction occurred under mass transport control. This potential was determined by hydrodynamic voltammetry using a borate/chloride solution as supporting electrolyte on stainless steel rotating disc electrode. The results indicate that mass transfer coefficient (Km) increases with increasing of flow rate (Q) where .The electrochemical reactor proved to be efficient in removing zinc and was abl
... Show More