Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Protaper gutta-percha point F2 and medium fine accessory gutta-percha using lateral condensation technique,roots were left for 7 days with 100% humidity at 37ºC in an incubator. Roots were randomly divided into four groups according to technique used for removing the root filling material (ten teeth for each group): group I: reciprocating technique and Wave One system, group II: continuous technique and ProTaper retreatment system, group III: continuous technique and R-Endo system, group IV: continuous technique and D–RaCere treatment system. All the roots were radiographed before and after removal of gutta-percha from both bucco-lingual and mesiodistal directions using custom made platform and digital radiograph system RVG to havea digitized images. The total surface area of all root canals was measured before removal ofthe gutta-percha and the area of the remaining gutta-percha filling in the canals after retreatment procedure from both directions. These measurements were analyzed with Adobe Photoshop CS6 software, the percentage of removed gutta-percha calculated. Results: Statistical analysis was performed and the result showed group Ihad the highest mean values in removal of root canal filling material in both bucco-lingual and mesiodistal direction of dental radiograph and there were significant difference between group I and most of the other groups ,there were non significant difference between group II,group III and group IV. Conclusion: This study was showed all the used retreatment systems did notcompletely remove the root canal filling material. The reciprocating technique was most effective method for removing gutta-percha and sealer than continuous rotary technique
In today's digital era, the importance of securing information has reached critical levels. Steganography is one of the methods used for this purpose by hiding sensitive data within other files. This study introduces an approach utilizing a chaotic dynamic system as a random key generator, governing both the selection of hiding locations within an image and the amount of data concealed in each location. The security of the steganography approach is considerably improved by using this random procedure. A 3D dynamic system with nine parameters influencing its behavior was carefully chosen. For each parameter, suitable interval values were determined to guarantee the system's chaotic behavior. Analysis of chaotic performance is given using the
... Show MoreA remarkable correlation between chaotic systems and cryptography has been established with sensitivity to initial states, unpredictability, and complex behaviors. In one development, stages of a chaotic stream cipher are applied to a discrete chaotic dynamic system for the generation of pseudorandom bits. Some of these generators are based on 1D chaotic map and others on 2D ones. In the current study, a pseudorandom bit generator (PRBG) based on a new 2D chaotic logistic map is proposed that runs side-by-side and commences from random independent initial states. The structure of the proposed model consists of the three components of a mouse input device, the proposed 2D chaotic system, and an initial permutation (IP) table. Statist
... Show MoreAbstract
The aim of this work is to create a power control system for wind turbines based on fuzzy logic. Three power control loop was considered including: changing the pitch angle of the blade, changing the length of the blade and turning the nacelle. The stochastic law was given for changes and instant inaccurate assessment of wind conditions changes. Two different algorithms were used for fuzzy inference in the control loop, the Mamdani and Larsen algorithms. These two different algorithms are materialized and developed in this study in Matlab-Fuzzy logic toolbox which has been practically implemented using necessary intelligent control system in electrical engineerin
... Show MoreThis paper presents a new approach to discover the effect of depth water for underwater visible light communications (UVLC). The quality of the optical link was investigated with varying water depth under coastal water types. The performance of the UVLC with multiple input–multiple output (MIMO) techniques was examined in terms of bit error rate (BER) and data rate. The theoretical result explains that there is a good performance for UVLC system under coastal water.
Abstract:
Objective: The study aim is to assess knowledge of secondary schools female students regarding dysmenorrhea; find out the effectiveness of education program on secondary schools students and also to identify relationship between education program and certain variables.
Methodology: The quasi-experimental design (pretest and posttest) on one hundred students 4th year in Khawla Bint Al-Azwar secondary school for females at morning shift in Al Nasiriya City, data collection started at 4th March to 18th March 2018. A non-probability (purposive) sample of (100) students (50) student from scientific branch and (50) students from literary branch. Data have been collected through using a questionnaire modeled and made up of
Objectives: To identify the effectiveness program on nurse- midwife practice concerning performed
cardiotocography to pregnant women and to find out the relationship between nurse- midwife practice and
certain studied variables.
Methodology: A quasi-experimental design (pretest-post test approach) was conducted at three sector AlRussafa
directorate, AL- Karckh directorate and Medical City Directorate from the period of March, 26th 2014
to August, 30th 2015. A non-probability sample consisted of (130) nurse -midwives were selected and divided
into two groups (65) nurses-midwives (case group) who exposed to the educational program and (65 ) nursesmidwives
who didn't expose to the program considered as control group . D
In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu
Background: The surgical treatment of pilonidal sinus varies from wide excision and laying the wound open or excision with primary closure or excision with the use of skin graft in some special cases.
Objectives: The objectives of this study is to determine the efficacy of treating non complicated pilonidal sinus disease with minimal excision and primary closure technique, complications and recurrence rate.
Patients and methods: This is a prospective study conducted in shahid ahmed ismaiel hospital in rania – As sulaimania IRAQ during the period from December 2013 to January 2016 and was carried on one hundred (100) consecutive patients with non complicated non recurrent pilonidal sinus patients who were treated with minimal exci
In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio
... Show More